The UNI-T UT501C is an insulation resistance tester with selectable 100V / 250V / 500V / 1000V output, a listed insulation span up to 5.00GΩ on the 1000V range, and an ACV 30V–750V (50/60Hz) check. Dial positions: 1000 / 500 / 250 / 100 / ACV / OFF. Terminals LINE / ACV / GUARD / EARTH; orange PRESS TO TEST with self-lock. Safety category listed CAT III 600V. Price as shown; free UK & Europe delivery.

Not UNI-T UT502C and not UT501A / UT501B / UT501E. This page is the UT501C only.

Match voltage, then press to test

The UT501C applies a chosen DC test voltage between LINE and EARTH so you can read insulation resistance on a suitable circuit that has been isolated and discharged. Use the ACV position only to check for residual AC before an insulation test — not as a substitute for a dedicated multimeter workflow.

  • Test voltages: 100V, 250V, 500V, 1000V
  • Insulation ranges (by voltage): 100V → 0.00MΩ–100MΩ; 250V → 0.00MΩ–500MΩ; 500V → 0.00MΩ–2.00GΩ; 1000V → 0.00MΩ–5.00GΩ (overall span listed 0.0MΩ–5.0GΩ)
  • Accuracy (UNI-T): 0.00MΩ–99.9MΩ ±(3%+5); 100MΩ–5.00GΩ ±(5%+5)
  • ACV: 30V–750V, 50/60Hz, ±(2%+3)
  • Short-circuit current about <2mA; rated test current about 1.0–1.1mA
  • Functions: auto range, auto power off, data hold, backlight, auto discharge, low battery, overrange, audible/visual alarm, self-lock (PRESS TO TEST)
  • Safety: CAT III 600V
  • Power: 6 × 1.5V AA; size about 183.5 × 115 × 74 mm; about 0.6kg with batteries

How to take a useful reading

  1. Isolate the circuit under test and discharge stored energy before connecting leads. Confirm the system is safe to approach.
  2. Select the test voltage that matches the insulation class and the method you are following (100 / 250 / 500 / 1000V). Do not default to 1000V unless the method calls for it.
  3. Connect LINE and EARTH as the manual describes; use GUARD when the method needs guard connection to reduce surface leakage influence.
  4. Use ACV only to check for residual AC on a suitable path — then return to an insulation range before PRESS TO TEST.
  5. Press and hold PRESS TO TEST (or lock as the manual allows), wait for a stable reading, then release and allow auto discharge before disconnecting.

See also: UNI-T UT501C: Match Test Voltage Before You Press.

Specifications

  • Model: UNI-T UT501C
  • Type: Insulation resistance tester
  • Dial: 1000 / 500 / 250 / 100 / ACV / OFF
  • Output / test voltages: 100V, 250V, 500V, 1000V
  • Insulation range: 0.0MΩ–5.0GΩ overall (100V: 0.00MΩ–100MΩ; 250V: 0.00MΩ–500MΩ; 500V: 0.00MΩ–2.00GΩ; 1000V: 0.00MΩ–5.00GΩ)
  • Accuracy (UNI-T): 0.00MΩ–99.9MΩ ±(3%+5); 100MΩ–5.00GΩ ±(5%+5)
  • ACV: 30V–750V (50/60Hz), ±(2%+3)
  • Short-circuit current: about <2mA
  • Rated test current: about 1.0–1.1mA
  • Terminals: LINE, ACV, GUARD, EARTH
  • Key: PRESS TO TEST (self-lock)
  • Functions: auto range, auto power off, data hold, backlight, auto discharge, low battery, overrange, audible/visual alarm, self-lock
  • Safety: CAT III 600V
  • Power: 6 × 1.5V AA
  • Size: ~183.5 × 115 × 74 mm
  • Weight: ~0.6kg (with batteries)

Confirm the current kit (host, test leads, alligator clips, strap, soft bag, manual, 6×AA, gift box) on this buying page before ordering. Follow the supplied manual for operating limits, connection diagrams and safety warnings.

Free delivery to the UK and Europe. Dispatched in 1–2 working days, delivered in 5–7 working days. Price as shown; taxes at checkout. VAT invoices available where applicable.

Get to know the UNI-T UT501C

Test-voltage choice, LINE/EARTH connections and model distinctions before you choose. Learn more →

See also: UNI-T UT501C: Match Test Voltage Before You Press.

FAQ

Is delivery free?

Yes. Free delivery to the UK and Europe. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. Price as shown; taxes at checkout.

In use: prepare an isolated insulation check

Connect the exact tester to a fully disconnected cable or motor winding on an insulating bench. Keep the asset unpowered, use only the documented terminals and test method, and leave the display unreadable so no test result is invented.

UNI-T UT501C Insulation Resistance Tester insulation tester connected to a disconnected cable on an insulating bench
AI-generated scene illustration using product reference images: UNI-T UT501C Insulation Resistance Tester insulation tester connected to a disconnected cable on an insulating bench. This illustrates placement and workflow, not a measured result or an included-accessory list.

Technical specifications

SpecificationValue
ModelUNI-T UT501C
TypeInsulation resistance tester
Dial1000 / 500 / 250 / 100 / ACV / OFF
Test voltages100V, 250V, 500V, 1000V
Insulation range0.0MΩ–5.0GΩ overall (by V: 100MΩ / 500MΩ / 2.00GΩ / 5.00GΩ)
Accuracy (listed)0.00MΩ–99.9MΩ ±(3%+5); 100MΩ–5.00GΩ ±(5%+5)
ACV30V–750V, 50/60Hz, ±(2%+3)
Short-circuit / rated current~<2mA / ~1.0–1.1mA
TerminalsLINE, ACV, GUARD, EARTH
FunctionsAuto range, APO, hold, backlight, auto discharge, low battery, overrange, alarm, self-lock
SafetyCAT III 600V
Power6 × 1.5V AA
Size / weight~183.5 × 115 × 74 mm / ~0.6kg (with batteries)
FAQ

What test voltages does the UT501C provide?

UNI-T lists selectable 100V, 250V, 500V and 1000V insulation test outputs on the dial. Match the voltage to the insulation class and the method you are following.

What insulation resistance range is listed?

Overall span is listed 0.0MΩ–5.0GΩ. By voltage: 100V up to 100MΩ; 250V up to 500MΩ; 500V up to 2.00GΩ; 1000V up to 5.00GΩ. Accuracy: 0.00MΩ–99.9MΩ ±(3%+5); 100MΩ–5.00GΩ ±(5%+5). Follow the manual for conditions.

What is the ACV position for?

ACV measures about 30V–750V at 50/60Hz so you can check for residual AC before an insulation test. It is not a full substitute for a dedicated multimeter workflow.

Which terminals do I use for an insulation test?

LINE and EARTH for the insulation measurement path. Use GUARD when the method requires it. Follow the supplied manual for diagrams and safety steps.

What safety category is listed?

CAT III 600V as listed by UNI-T for this model. Stay within the rated category and the limits in the manual.

Is this the same as UT502C or UT501A/B/E?

No. This page is UNI-T UT501C only. Do not assume UT502C or UT501A/B/E specifications apply here.

Is UK delivery free?

Yes. Free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch.

Related instruments
Delivery & returns
When will my order arrive?

Dispatched within 1–2 working days. Delivered in 5–7 working days after dispatch.

What is the return policy?

You can return a product within 30 days. See our returns page for details.

Is checkout secure?

Payment is processed through Shopify's secure checkout.

How can I contact support?

Email support@ekodeluxe.co.uk.

UNI-T UT501C Insulation Resistance Tester
$121.00