PRODUCT OVERVIEW
Match the test voltage.Connect LINE and EARTH.
The UNI-T UT501C is an insulation resistance tester for suitable isolated circuits. You choose a DC test voltage on the dial, connect LINE and EARTH (GUARD when the method needs it), then use PRESS TO TEST. That workflow is different from a clamp meter, a multimeter-only check, or a separately listed UT502C.

HOW TO APPROACH IT
A four-voltage insulation tester with an ACV check.
The UT501C lists 100V, 250V, 500V and 1000V insulation outputs, ranges up to 5.00GΩ on the 1000V setting, and an ACV 30V–750V (50/60Hz) position for residual-voltage checks. Dial silk: 1000 / 500 / 250 / 100 / ACV / OFF. Use it when the task calls for a dedicated insulation resistance test — not as a generic everyday multimeter.
Match the test voltage first
Higher voltage is not always better. Choose 100 / 250 / 500 / 1000V to match the insulation class and the method you are following before you compare readings across a job.
Connect LINE and EARTH deliberately
Insulation readings depend on a correct LINE–EARTH path. Add GUARD when surface leakage would otherwise pull the result. Do not improvise connections that the manual does not describe.
Keep ACV separate from insulation ranges
Use ACV only to check for residual AC, then return to an insulation voltage before PRESS TO TEST. Mixing the two roles on the same step is a common setup error.
WHY THE METHOD MATTERS
Make isolation and discharge part of the result.
Isolate, discharge, match voltage, then press — in that order.

TYPICAL TASKS
Where this meter earns its place.
Screen insulation after isolation
Confirm the circuit is de-energised and discharged, then apply the chosen test voltage between the points the method names.
Check for residual AC first
Where appropriate, use the ACV position to look for leftover AC before an insulation run.
Plan for auto discharge
After the test, allow the instrument’s auto discharge to complete before you disconnect leads.
FIT CHECK
Is this the right shortlist?
A good shortlist for
- Insulation resistance checks on suitable isolated wiring and equipment within the listed ranges.
- Users who need selectable 100–1000V, data hold, backlight and self-lock PRESS TO TEST.
- Comparative checks when the same test voltage and connection method stay consistent.
Check these limits first
- It is not a clamp meter and not a full multimeter substitute.
- ACV is a residual-check aid (30V–750V, 50/60Hz) — not a blanket live-work tool.
- Do not assume UT502C or UT501A/B/E specifications apply to this page.
- Safety is listed CAT III 600V only — follow the supplied manual for category limits and warnings.
- Accuracy figures are listed under manufacturer conditions — follow the supplied manual.
| Specification | UNI-T UT501C |
|---|---|
| Model | UT501C |
| Type | Insulation resistance tester |
| Dial | 1000 / 500 / 250 / 100 / ACV / OFF |
| Test voltages | 100V, 250V, 500V, 1000V |
| Insulation range | 0.0MΩ–5.0GΩ overall (by V: 100 / 500 / 2.00G / 5.00GΩ) |
| Accuracy (listed) | 0.00MΩ–99.9MΩ ±(3%+5); 100MΩ–5.00GΩ ±(5%+5) |
| ACV | 30V–750V, 50/60Hz, ±(2%+3) |
| Short-circuit / rated current | ~<2mA / ~1.0–1.1mA |
| Terminals | LINE, ACV, GUARD, EARTH |
| Functions | Auto range, APO, hold, backlight, auto discharge, low battery, overrange, alarm, self-lock |
| Safety | CAT III 600V |
| Power | 6 × 1.5V AA |
| Size / weight | ~183.5 × 115 × 74 mm / ~0.6kg (with batteries) |
Specifications describe the reviewed UNI-T model and source. Follow the supplied manual for range, accuracy conditions, connection diagrams and operating limits. Confirm the current kit on the buying page before ordering.
GET THE CONTEXT
Learn before you choose.
Start with the model-specific how-to, then widen to related tester choices if needed.
Isolate and discharge, match the test voltage, connect LINE and EARTH, then PRESS TO TEST — and keep ACV separate from insulation ranges.
Read the guide → FROM THE LEARNING CENTREChoose the right electrical testerCompare tester types and understand which specifications matter for your work.
Read the guide →A FEW MORE DETAILS
Your questions, answered.
Do I always use 1000V?
No. Match 100 / 250 / 500 / 1000V to the insulation class and the method. Defaulting to the top voltage is a common mistake.
What are LINE, EARTH and GUARD for?
LINE and EARTH form the insulation measurement path. GUARD is used when the method needs a guard connection to reduce surface-leakage influence. Follow the manual diagrams.
Can ACV replace a multimeter?
No. ACV on this dial is a residual-voltage check (about 30V–750V, 50/60Hz) before an insulation test — not a full multimeter workflow.
Is this UT502C or UT501A/B/E?
No. UT501C is the insulation resistance tester on this overview. Do not mix their specifications or product images.
Ready to buy the UNI-T UT501C?
UK stock, VAT included, free UK delivery. SKU EKO-UT501C.
Product information: UNI-T manufacturer specifications and the EkoDeluxe product listing. Overview checked 2 November 2026. For operating instructions, use the supplied manual. Model UNI-T UT501C · SKU EKO-UT501C.