Basket
EkoDeluxe / All instruments / VICTOR VC960B

VICTOR VC960B · PRODUCT OVERVIEW

Choose the test voltage.Keep the result in context.

The VC960B combines five insulation-test voltage settings with True RMS multimeter functions. PI/DAR and timed-test controls support structured insulation checks, while a backlit display and HOLD help record the result.

VICTOR VC960B product view
5 settings50 / 100 / 250 / 500 / 1000 V
20.00 GΩListed insulation display maximum
PI / DARInsulation analysis modes
True RMSListed meter capability

UNDERSTAND THE INSTRUMENT

Voltage, time and resistance belong together.

The VC960B combines five insulation-test voltage settings with True RMS multimeter functions. PI/DAR and timed-test controls support structured insulation checks, while a backlit display and HOLD help record the result.

01

Match voltage to the equipment

The five voltage settings suit different test requirements. Select from the equipment instructions and applicable procedure, with sensitive electronics disconnected where required.

02

Use time as part of the measurement

PI/DAR and timed modes compare insulation behaviour over time. Correct connection, duration, temperature and equipment condition matter to interpretation.

03

Follow the discharge procedure

The listing describes automatic discharge after insulation testing. Follow the manual and verify the required safe state before touching or reconnecting conductors.

VICTOR VC960B functions and display

FROM FEATURES TO TASKS

Make an insulation reading comparable.

Choose the measurement method, setup and record that fit the task.

Prepare a motor or cable test

Establish isolation and the required test configuration before selecting the voltage. Record the equipment identity with each result.

Compare readings over time

Repeat the same voltage, duration and connection points where the procedure calls for trending. Note environmental conditions.

Use the meter for a separate check

Select the supported voltage, resistance, capacitance or frequency function deliberately; insulation mode and everyday meter mode are different tests.

BEFORE YOU CHOOSE

Find the fit for your work.

A good shortlist for

  • Competent users needing insulation and meter functions together.
  • Procedures using timed tests or PI/DAR.
  • Recorded equipment checks with defined test conditions.

Check these limits first

  • A maximum resistance display does not guarantee accuracy at every voltage or range.
  • Automatic discharge does not replace the prescribed verification procedure.
  • Printed CAT markings are not an independent certification statement.

THE ESSENTIALS

Key specifications.

Specification VICTOR VC960B
Test voltages 50 / 100 / 250 / 500 / 1000 V
Insulation display maximum 20.00 GΩ listed
Insulation modes PI / DAR; timed test; automatic discharge
Meter functions AC/DC voltage, resistance, capacitance, diode, continuity and frequency
Meter readout True RMS; backlit LCD; HOLD
Voltage ranges DC up to 1000 V; AC up to 750 V listed

Specifications describe the reviewed model and source. Follow the supplied manual for range, accuracy conditions and operating limits. Confirm the current kit and accessories before ordering.

GET THE CONTEXT

Learn before you choose.

These guides explain the wider measurement questions behind the product.

A FEW MORE DETAILS

Your questions, answered.

Does it offer 50 V and 100 V tests?

Yes. The reviewed listing gives 50, 100, 250, 500 and 1000 V settings. Select the one specified for the equipment.

What do PI and DAR add?

They compare insulation resistance at defined times. They need the correct procedure and conditions; they are not universal pass/fail guarantees.

Is it a normal multimeter too?

It includes the listed meter functions alongside insulation testing. Confirm the correct function, inputs and limits for each task.

Explore the VC960B buying options.

Check the buying page for the current price, availability, kit contents and delivery information.

View price & buy →

Product information: EkoDeluxe model and kit information. Overview checked 31 October 2026. For operating instructions, use the supplied manual.