This EkoDeluxe guide explains, at a high level, how to use an insulation tester (insulation resistance tester / “megger tester”) for UK electrical work. It is selection and orientation help — not a method statement, not BS 7671 training, and not a substitute for your company’s safe systems of work.

Before you test

  • Isolate and prove dead using your approved procedure.
  • Disconnect sensitive electronics that must not see the test voltage.
  • Choose a test voltage the equipment and meter both allow (often 250 / 500 / 1000 V).
  • Inspect leads and the instrument; follow the manufacturer’s manual.

Typical test flow (overview)

  1. Select insulation resistance mode and the appropriate DC test voltage.
  2. Connect leads to the conductors under test as the manual shows.
  3. Start the test; wait for a stable reading in MΩ or GΩ.
  4. Note the result; many meters auto-discharge — still treat conductors as live until verified safe.

Interpretation (pass/fail thresholds) depends on the installation standard, the equipment maker and your competence. Do not treat this page as a pass/fail chart.

What the reading means in plain terms

Higher insulation resistance generally indicates better insulation condition for that test setup. Very low readings can indicate moisture, damage or contamination — investigate using your own procedures. Some advanced jobs use PI/DAR style ratios; see our PI/DAR guide when published, and only use features confirmed on the product page.

Live insulation testers at EkoDeluxe

Browse insulation testers and the buying guide / FAQ.

Free UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Prices incl. VAT, VAT invoices available.

FAQ

Is this a full test procedure?

No. It is a high-level overview. Follow manufacturer manuals, your training and applicable UK standards.

What voltage should I use?

Match selectable 250 / 500 / 1000 V (or other listed values) to the circuit and equipment guidance.

Can I test with appliances still connected?

Many sensitive devices must be disconnected before an insulation test — follow the equipment maker and your safe isolation process.

Megger tester or insulation tester?

In UK search language they usually mean the same instrument type; Megger is also a brand.