1Basket
UNI-T UT533 Insulation Multimeter — front English UI 0.000 Auto Range DC V silk UT533 TRUE RMS

UNI-T UT533 Insulation Multimeter

$334.00
Free delivery · incl. VAT
Quantity
or
VAT invoices
30-day returns
Secure payment
UK consumer rights apply
Product details

The UNI-T UT533 combines multimeter measurements with selectable 50 V, 100 V, 250 V, 500 V and 1000 V insulation tests. It has separate insulation and multimeter terminals; the True RMS marking applies to the AC voltage measurement path, not to insulation resistance.

The UNI-T UT533 is a handheld insulation multimeter — a digital multimeter with a dedicated insulation test arc — not a dedicated megohmmeter like UT505A/B. Face silk: UNI-T UT533 INSULATION MULTIMETER. English UI on this capture: 0.000 / Auto Range / DC / V. Face silk marks TRUE RMS (AC voltage path). Insulation dial (blue arc): 50V / 100V / 250V / 500V / 1000V. Other dial positions cover AC/DC voltage (V~ · V⎓ · mV), resistance / continuity / diode (Ω), mA and OFF. Keys include HOLD (LOCK above) · SAVE · MAX · RANGE (TEST VOLTAGE above) · backlight/CLR · LOAD · MIN · SELECT · yellow POWER · blue TEST / Hz. Terminals: INSULATION · mA (FUSED 250V MAX / 600mA MAX) · COM · V Ω °F °C (continuity / diode / Hz). Safety silk: CAT IV 600V · CAT III 1000V. UK price , free delivery.

Not UNI-T UT531 or UT532, not UT505A ( dedicated handheld insulation resistance tester), and not UT505B ( dedicated IR tester). This page is the UT533 insulation multimeter only — DMM functions plus insulation test voltages 50–1000V, English UI 0.000 / Auto Range / DC / V, face TRUE RMS for the AC voltage path, terminals INSULATION · mA · COM · V Ω °F °C, and silk CAT IV 600V / CAT III 1000V. Do not use 531/532/505* co-branded images or another model’s photo for ranges or accessories. Insulation resistance upper span (GΩ) is not stated from readable silk on this capture — follow the supplied manual for the resistance span.

Insulation multimeter: DMM paths plus 50–1000V insulation

The UT533 combines everyday multimeter positions with a blue-arc INSULATION section so you can choose a DC test voltage (50 / 100 / 250 / 500 / 1000V) on suitable isolated circuits, then return to voltage, resistance / continuity / diode or mA work on the same body. Face TRUE RMS silk applies to the AC voltage path — not an “insulation True RMS” claim. Use the INSULATION jack with the path the manual describes for insulation tests; use V Ω °F °C with COM for the voltage / ohms / temperature / Hz workflows the dial allows. Stay within the marked CAT IV 600V / CAT III 1000V limits and the warnings in the supplied manual. Confirm kit contents on this buying page before ordering.

  • Type: Insulation multimeter (DMM + insulation) — not a dedicated megohmmeter
  • Face silk: UNI-T UT533 INSULATION MULTIMETER
  • English UI example: 0.000 / Auto Range / DC / V
  • True RMS: face silk (AC voltage path)
  • Insulation dial (blue arc): 50V, 100V, 250V, 500V, 1000V
  • Other dial: OFF · V~ · V⎓ · mV · Ω (resistance / continuity / diode) · mA
  • Keys: HOLD (LOCK above) · SAVE · MAX · RANGE (TEST VOLTAGE above) · backlight/CLR · LOAD · MIN · SELECT · yellow POWER · blue TEST / Hz
  • Terminals: INSULATION · mA (FUSED 250V MAX / 600mA MAX) · COM · V Ω °F °C (continuity / diode / Hz)
  • Temperature path: °F / °C silk on the V jack — follow the manual for probe use; no invented probe accuracy
  • Safety silk: CAT IV 600V · CAT III 1000V
  • Insulation resistance span (GΩ): follow the supplied manual — not claimed from readable silk on this page
  • Battery / weight: follow the supplied manual for battery; confirm kit weight on this buying page

How to take a useful reading

  1. Isolate the circuit under test and discharge stored energy before connecting leads. Confirm the system is safe to approach.
  2. For insulation work, select 50 / 100 / 250 / 500 / 1000V on the blue INSULATION arc to match the insulation class and the method you are following. Do not default to 1000V unless the method calls for it. Use RANGE (TEST VOLTAGE above) only as the manual describes.
  3. Connect the INSULATION jack and the return path the manual diagrams for insulation tests. Use V Ω °F °C with COM only for voltage / ohms / temperature / Hz workflows — do not improvise insulation connections on the V jack.
  4. Press the blue TEST / Hz key for the insulation test as the manual describes; wait for a stable reading. Use HOLD (LOCK above) or SAVE if you need to step away to note the value.
  5. For multimeter work, select the matching dial position (V~, V⎓, mV, Ω, mA), observe the fused 600mA MAX limit on the mA path, and stay within CAT IV 600V / CAT III 1000V.

See also: UNI-T UT533: Pick Insulation Voltage Before You Press TEST.

Specifications

  • Model: UNI-T UT533
  • Type: Insulation multimeter (handheld DMM + insulation)
  • Face silk: UNI-T UT533 INSULATION MULTIMETER
  • English UI example: 0.000 / Auto Range / DC / V
  • True RMS: face silk (AC voltage path) — not an insulation-True-RMS claim
  • Insulation test voltages (blue arc): 50V / 100V / 250V / 500V / 1000V
  • Other dial: OFF · V~ · V⎓ · mV · Ω (resistance / continuity / diode) · mA
  • Keys: HOLD (LOCK) · SAVE · MAX · RANGE (TEST VOLTAGE) · backlight/CLR · LOAD · MIN · SELECT · POWER · TEST / Hz
  • Terminals: INSULATION · mA FUSED 250V MAX / 600mA MAX · COM · V Ω °F °C (continuity / diode / Hz)
  • Temperature: °F / °C path on terminal silk — follow manual for probe; accuracy not invented here
  • Safety silk: CAT IV 600V · CAT III 1000V
  • Insulation resistance span: follow the supplied manual (GΩ upper figure not claimed from readable silk on this capture)
  • Weight: handheld unit — confirm kit weight on this buying page (not stated as silk fact)
  • Battery: follow the supplied manual for battery type

Confirm leads, case, manual, temperature probe and any kit shown on this buying page before ordering. Follow the supplied manual for insulation procedure, resistance span, accuracy conditions, connection diagrams and safety warnings. Do not treat this page as UT531, UT532, UT505A or UT505B. Capacitance is not claimed from readable dial silk on this capture. Accuracy percentages and insulation GΩ limits are not invented here — use the manual.

Free UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.

Get to know the UNI-T UT533

Insulation multimeter layout, pick the insulation voltage before TEST, True RMS voltage path, INSULATION vs V terminals, CAT IV 600V / CAT III 1000V and how it differs from UT505A/B. Learn more →

See also: UNI-T UT533: Pick Insulation Voltage Before You Press TEST.

FAQ

How is UT533 different from UT505A and UT505B?

UT533 is an insulation multimeter (DMM + 50–1000V insulation). UT505A and UT505B are dedicated handheld insulation resistance testers with PI/DAR/COMP-class workflows and listed GΩ spans on their own pages. Do not mix photos, GΩ claims or procedures across these models. Not UT531, not UT532.

Technical specifications

SpecificationValue
ModelUNI-T UT533
TypeInsulation multimeter (DMM + insulation)
Face silkUNI-T UT533 INSULATION MULTIMETER
English UI example0.000 / Auto Range / DC / V
True RMSFace silk — AC voltage path (not insulation True RMS)
Insulation test voltages50V / 100V / 250V / 500V / 1000V (blue arc)
Other dialOFF · V~ · V⎓ · mV · Ω · mA
KeysHOLD(LOCK) · SAVE · MAX · RANGE(TEST VOLTAGE) · CLR · LOAD · MIN · SELECT · POWER · TEST/Hz
TerminalsINSULATION · mA FUSED 250V MAX/600mA MAX · COM · V Ω °F °C
Safety silkCAT IV 600V · CAT III 1000V
Insulation GΩ spanFollow supplied manual (not claimed from readable silk)
Battery / weightFollow manual for battery; confirm kit weight on buying page
FAQ

What is an insulation multimeter — is UT533 a dedicated megohmmeter?

An insulation multimeter combines DMM functions (voltage, resistance / continuity / diode, mA, and on this face a temperature path) with selectable insulation test voltages on one handheld body. The UT533 face silk reads INSULATION MULTIMETER. It is not a dedicated insulation resistance tester like UT505A or UT505B .

What insulation test voltages does the UT533 provide?

The blue INSULATION arc lists 50V / 100V / 250V / 500V / 1000V. Match the voltage to the insulation class and the method you are following — do not default to 1000V by habit. Follow the supplied manual for the insulation resistance span (GΩ is not claimed from readable silk on this page).

What does TRUE RMS cover on this meter?

Face silk marks TRUE RMS. On this listing that mark is treated as applying to the AC voltage path. It is not an insulation True RMS claim.

Which terminals do I use — INSULATION vs V Ω °F °C?

Insulation tests use the INSULATION jack with the return path the manual diagrams. Voltage, resistance / continuity / diode, temperature (°F/°C) and Hz workflows use V Ω °F °C with COM. The mA jack is marked FUSED 250V MAX / 600mA MAX. Do not improvise insulation connections on the V jack.

What safety categories are marked?

Face / terminal silk lists CAT IV 600V and CAT III 1000V. Stay within those markings and the category / voltage limits in the supplied manual. Observe the fused 600mA MAX note on the mA path.

How is UT533 different from UT505A and UT505B?

UT533 is an insulation multimeter (DMM + 50–1000V insulation). UT505A and UT505B are dedicated handheld insulation resistance testers with PI/DAR/COMP-class workflows and listed GΩ spans on their own pages. Do not mix photos, GΩ claims or procedures. Not UT531, not UT532.

What do HOLD / LOCK and RANGE / TEST VOLTAGE do?

HOLD has LOCK silk above it; RANGE has TEST VOLTAGE silk above it. Use them as the supplied manual describes for display hold / lock and for selecting or confirming test voltage behaviour — do not invent lock timing or voltage-step rules on this page.

What does the blue TEST / Hz key do, and is UK delivery free?

The blue key is labelled TEST / Hz — use TEST for the insulation run and Hz on the frequency path as the manual allows. Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch.

Related instruments
Delivery & returns
When will my order arrive?

Dispatched within 1–2 working days. Delivered in 5–7 working days after dispatch.

What is the return policy?

You can return a product within 30 days. See our returns page for details.

Is checkout secure?

Payment is processed through Shopify's secure checkout.

How can I contact support?

Email support@ekodeluxe.co.uk.

UNI-T UT533 Insulation Multimeter