The UNI-T UT278A is a clamp-on ground tester for earth-resistance and leakage-current checks on suitable loops. This listing is the UT278A without a plus suffix, with HOLD, SAVE, alarm and memory controls. Its supplier-listed jaw opening is 32 mm.

The UNI-T UT278A is a handheld GROUND TESTER for clamp-on earth-resistance and leakage-current checks on suitable loops — not a stake-style digital earth tester (≠ UT521 / UT522), not an Earth-ρ Tester (≠ UT523A), and not a multi-model 278A+ / 278B / 278C / 278D / 276A / 275 / 275A / 272A poster. Face silk: UNI-T UT278A GROUND TESTER (no +). English UI on this capture: main 0.00 AC mA · sub-display 03 · screen mark HOLD (raw_1 / raw_2). Keys: large round HOLD · power icon · SAVE · AL · A / arrow · MEM / square icon. Body: CE. Jaw trigger opens/closes the clamp. Supplier attributes (not face silk): measuring range 0.01–1200 Ω, leakage current through 30 A, jaw opening 32 mm, RS-232, data storage 99, visual / audible alarm, auto range. Kit capture (raw_6) may show case · 4×AA · RS-232 cable · 1 Ω / 10 Ω / 100 Ω verification rings — confirm kit contents on this buying page and in the supplied manual. The included manual cover may read UT276A/278A (shared OEM cover for the pair) — that is not a second buyable model on this SKU; face silk UT278A rules. Estimated freight weight about 1.40 kg (weight_est=Y) — confirm weight on this buying page. UK price , free delivery.

Not a plus-suffix listing sold as UT278A+ on other channels, not UT278B / C / D, not UT276A (shared manual cover is not a second model here), not UT275 ( — EARTH CLAMP TESTER · 100 Ω / 01 · CAT III 300V), not UT275A ( — Earth Clamp Meter · 10.0 Ω · MAX 30A~ · CAT IV 600V), not UT272A , not a stake-driven digital earth tester (UT521 / UT522), and not an Earth-ρ Tester (UT523A). This page is the bare UT278A GROUND TESTER only — English UI 0.00 AC mA / 03 / HOLD, keys HOLD · SAVE · AL · A · MEM, jaw opening 32 mm (supplier). Do not use 278A+ / 278B/C/D / 276A / 275 / 275A / 272A co-branded images or another model’s photo for ranges or accessories. Loop-test step counts and pass/fail limits are not invented here — follow the method you are working to and the supplied manual. Respect supplier jaw opening 32 mm and leakage path through 30 A.

Ground Tester: confirm bare UT278A silk — not a plus-suffix listing

The UT278A is built for clamp-on earth-resistance and leakage-current readings: power on, close the jaw around a suitable earth conductor / loop, read the English UI (resistance path or leakage / AC mA path as the supplied manual describes), then use large HOLD, SAVE, AL, A and MEM as the manual describes. That is a different instrument class from UT521 / UT522 stake-style digital earth testers and from UT523A’s ρEARTH / REARTH / EARTH VOLTAGE dial — and a different listing from recently published UT275 ( EARTH CLAMP TESTER), UT275A ( Earth Clamp Meter) and UT272A , and from near models UT278B / C / D and UT276A. Confirm the face silk UT278A GROUND TESTER (no +), the English UI 0.00 AC mA / 03 / HOLD, and supplier jaw opening 32 mm before you compare prices or procedures. A shared manual cover marked UT276A/278A does not make UT276A the sellable model on this page. This page does not invent loop-test step counts or legal pass/fail limits — follow the method you are working to and the supplied manual. Confirm kit contents on this buying page before ordering.

  • Type: GROUND TESTER — clamp-on earth resistance + leakage current (paths per manual)
  • Face silk: UNI-T UT278A GROUND TESTER (no +)
  • English UI example: 0.00 AC mA · sub-display 03 · screen HOLD (raw_1/2)
  • Keys: large HOLD · power icon · SAVE · AL · A / arrow · MEM / square
  • Body marking: CE
  • Jaw opening (supplier attribute): 32 mm
  • Resistance (supplier attribute): 0.01–1200 Ω
  • Leakage current (supplier attribute): through 30 A
  • Interface / memory (supplier attribute): RS-232 · data storage 99 · visual / audible alarm · auto range
  • Kit (raw_6 support): case · 4×AA · RS-232 · 1 Ω / 10 Ω / 100 Ω rings — confirm on this buying page
  • Manual cover: may show UT276A/278A shared OEM cover — face silk UT278A rules; do not sell as UT276A
  • Weight: freight estimate about 1.40 kg (weight_est=Y) — confirm weight on this buying page
  • Loop-check steps / pass-fail limits: follow the method and supplied manual — not invented here
  • Strong contrast to plus-suffix / near models: bare UT278A only — do not share photos or copy with UT278A+ / UT278B/C/D / UT276A / UT275 / UT275A / UT272A

How to take a useful reading

  1. Confirm the earth conductor / loop under test is safe to approach and that the method you are following allows a clamp-on earth-resistance or leakage-current check at this point. Observe the warnings in the supplied manual and all markings on the unit.
  2. Power on with the power icon. Select the resistance or leakage / AC mA path as the supplied manual describes — before you treat a number as meaningful. Do not invent loop-test step counts or pass/fail limits on this page. Do not borrow UT275 POWER / MODE layouts, UT275A combined Ω/A · READ expectations, UT521 / UT522 stake-method expectations, or UT523A ρEARTH / REARTH dial paths as if they were this meter.
  3. Open the jaw with the trigger, seat the clamp fully around the conductor / loop within the supplier jaw opening 32 mm, and close the jaw so the reading path is complete.
  4. Read the English UI (0.00 AC mA class · sub-display 03 · screen HOLD on this capture when HOLD is active). Use large HOLD, SAVE, AL, A and MEM as the manual describes when you need to hold, store, alarm or navigate memory.
  5. Record path context, clamp-point identity and the reading with the method reference. This page does not declare a legal pass/fail for the installation.

See also: UNI-T UT278A: Confirm Bare UT278A — Not UT278A+.

Specifications

  • Model: UNI-T UT278A (bare — no +)
  • Type: GROUND TESTER (clamp-on earth resistance + leakage current)
  • Face silk: UNI-T UT278A GROUND TESTER
  • English UI example: 0.00 AC mA · sub-display 03 · screen HOLD
  • Keys: large HOLD · power icon · SAVE · AL · A / arrow · MEM / square
  • Body marking: CE
  • Jaw opening (supplier attribute): 32 mm
  • Resistance (supplier attribute): 0.01–1200 Ω
  • Leakage current (supplier attribute): through 30 A
  • RS-232 · data storage 99 · visual / audible alarm · auto range (supplier attributes)
  • Kit / batteries: confirm on this buying page (raw_6 support may show case · 4×AA · RS-232 · verification rings)
  • Weight: confirm on this buying page (freight estimate about 1.40 kg; weight_est=Y)
  • Manual: shared UT276A/278A cover possible — face silk UT278A rules
  • Loop-check steps / pass-fail limits: follow the method you are working to and the supplied manual

Confirm batteries, case and any kit shown on this buying page before ordering. Follow the supplied manual for operating limits and safety warnings. Do not treat this page as a plus-suffix listing, UT278B / C / D, UT276A, UT275, UT275A, UT272A, UT521, UT522 or UT523A. Loop-test schedules are not invented here — use the manual and the method you are following.

Free UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.

Get to know the UNI-T UT278A — GROUND TESTER layout, bare UT278A silk (not a plus-suffix listing), English UI 0.00 AC mA / HOLD, HOLD · SAVE · AL · A · MEM, jaw opening 32 mm (supplier), and how it differs from UT275 / UT275A / UT272A / UT278B–D / UT276A / UT521 / UT522 / UT523A. Learn more →

In use: set up a repeatable ground observation

Use the exact tester with a visible training earth point or isolated test lead, keeping clamps and probes on the intended conductor. Show the test position and record sheet without a readable resistance value or a claim about the whole installation.

UNI-T UT278A Clamp-On Ground Resistance Tester ground tester positioned at an isolated earth test point
AI-generated scene illustration using product reference images: UNI-T UT278A Clamp-On Ground Resistance Tester ground tester positioned at an isolated earth test point. This illustrates placement and workflow, not a measured result or an included-accessory list.
FAQ

What does the UT278A measure?

It is a clamp-on GROUND TESTER for earth-resistance and leakage-current checks on suitable loops. Paths follow the supplied manual. That is a different instrument class from stake-style UT521 / UT522 digital earth testers and from UT523A’s Earth-ρ dial — and a different listing from UT275 / UT275A / UT272A and from plus-suffix / near-letter models.

Is this the same as a plus-suffix UT278A listing?

No. This page is bare UT278A only — face silk UT278A GROUND TESTER with no +. Plus-suffix listings on other channels are a different product identity and must not share photos, ranges or procedures with this SKU.

How is UT278A different from UT275 / UT275A / UT272A?

UT278A silk reads GROUND TESTER, English UI 0.00 AC mA / 03 / HOLD, keys HOLD · SAVE · AL · A · MEM, jaw opening 32 mm (supplier). UT275 is an EARTH CLAMP TESTER with 100 Ω / 01 and body CAT III 300V. UT275A is an Earth Clamp Meter with 10.0 Ω and jaw silk MAX 30A~ · CAT IV 600V. UT272A is a different Earth Clamp Meter listing. Do not share photos, ranges or procedures.

How is UT278A different from UT278B / C / D / UT276A?

Bare UT278A is this GROUND TESTER page only. UT278B / C / D and UT276A are different models. A shared manual cover marked UT276A/278A does not make UT276A the sellable model here — face silk UT278A rules.

How is UT278A different from UT521 / UT522 / UT523A?

UT278A clamps the conductor / loop. UT521 and UT522 are stake-style digital earth testers. UT523A is an Earth-ρ Tester. Do not share photos, ranges or procedures across these models.

What do the HOLD, SAVE and AL keys do?

Large HOLD freezes a value as the manual describes (screen can show HOLD). SAVE stores a reading; AL is the alarm key — use both as the supplied manual describes. A and MEM navigate / recall as the manual describes. This page does not invent memory-capacity marketing beyond the supplier attribute data storage 99.

What jaw opening and ranges apply?

Supplier attributes list jaw opening 32 mm, resistance 0.01–1200 Ω, and leakage current through 30 A. Loop-check step counts and legal pass/fail limits stay with the method you are working to and the supplied manual — not with this page.

Does the shared UT276A/278A manual mean I am buying UT276A?

No. The OEM manual cover may be shared for the pair; the buyable model on this page is bare UT278A per face silk. Do not treat UT276A as a second model or co-list it here.

How much does it weigh, and what is in the kit?

Freight estimate about 1.40 kg (weight_est=Y) — confirm weight on this buying page. Kit support capture (raw_6) may show case · 4×AA · RS-232 · verification rings — confirm full kit on this buying page and in the supplied manual.

Is UK delivery free?

Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch.

Related instruments
Delivery & returns
When will my order arrive?

Dispatched within 1–2 working days. Delivered in 5–7 working days after dispatch.