1Basket
UNI-T UT275A Earth Clamp Meter — front English UI 10.0 Ω silk UT275A jaw MAX 30A~ CAT IV 600V

UNI-T UT275A Earth Clamp Meter

$608.00
Free delivery · incl. VAT
Quantity
or
VAT invoices
30-day returns
Secure payment
UK consumer rights apply
Product details

GBP · VAT included · Free UK delivery · Dispatch in 1–2 working days · Delivered about 5–7 working days after dispatch

The UNI-T UT275A is a handheld Earth Clamp Meter for clamp-on ground-resistance checks on suitable loops — not a stake-style digital earth tester (≠ UT521 / UT522), not an Earth-ρ Tester (≠ UT523A), and not a multi-model 275-bare / 272A / 278 / 275+ poster. Face silk: UNI-T UT275A Earth Clamp Meter. English UI on this capture: 10.0 Ω (raw_1 / raw_2). Keys: orange power · blue HOLD (with backlight icon) · combined Ω/A · ↑ · OK (with Bluetooth icon) · READ · ↓ (silk CLEAR) · SAVE; face print includes FCC ID text and a yellow warning triangle; the screen can show Bluetooth / battery / APO icons. Jaw trigger opens/closes the clamp; jaw silk readable on priority captures: left MAX 30A~ · right CAT IV 600V (shop_note wrote CAT IV 300V — disk jaw silk overrides for copy). Back (raw_5): battery door AA 1.5V ×4, CE / ETL marks, no model text — usable as a support image. Supplier attributes (not face silk): measuring range 0 Ω ~ 2000 Ω, current range 0 A ~ 1 A, testing voltage 5 V, insulation resistance > 1 MΩ. Accuracy class on the source page is treated as uncertain — not used as a selling claim here. Confirm kit contents and weight on this buying page and in the supplied manual. UK price £455.43, free delivery.

Not a stake-driven digital earth tester (UT521 £274.67 / UT522 £294.83), not an Earth-ρ Tester (UT523A £1153.44), not UT275 bare, not UT272A (£276.51 — same Earth Clamp Meter class but different jaw silk / key layout / price), not UT278A / B, and not UT275+. This page is the UT275A Earth Clamp Meter only — English UI 10.0 Ω, combined Ω/A key, jaw silk MAX 30A~ · CAT IV 600V, face FCC ID + yellow triangle. Do not use 275-bare / 272A / 278* / 275+ co-branded images or another model’s photo for ranges or accessories. Clamp jaw opening size, loop-test step counts and pass/fail limits are not invented here — follow the method you are working to and the supplied manual. Respect jaw marking MAX 30A~.

Earth Clamp Meter: confirm MAX 30A~ jaw class before you compare to UT272A

The UT275A is built for clamp-on ground-resistance readings: close the jaw around a suitable earth conductor / loop, select the resistance side of the combined Ω/A key, read the English UI, then use HOLD / SAVE as the manual describes. Current / leakage-current style checks use the A side of that same key when the supplied manual allows it. That is a different instrument class from UT521 / UT522 stake-style digital earth testers and from UT523A’s ρEARTH / REARTH / EARTH VOLTAGE dial — and a different listing from the recently published UT272A (£276.51), which shares the Earth Clamp Meter class but uses separate Ω / A keys and jaw silk CAT IV 300V without a MAX 30A~ mark on the priority captures used there. Confirm the face silk UT275A Earth Clamp Meter, the English UI 10.0 Ω, and jaw silk MAX 30A~ · CAT IV 600V before you compare prices or procedures. This page does not invent jaw opening millimetres, ring-check step counts or legal pass/fail limits — follow the method you are working to and the supplied manual. Confirm kit contents on this buying page before ordering.

  • Type: Earth Clamp Meter — clamp-on ground resistance (A side per manual for current / leakage)
  • Face silk: UNI-T UT275A Earth Clamp Meter
  • English UI example: 10.0 Ω (raw_1/2)
  • Keys: orange power · blue HOLD (backlight icon) · Ω/A (combined) · ↑ · OK (Bluetooth icon) · READ · ↓ (CLEAR) · SAVE
  • Face print: FCC ID text · yellow warning triangle; screen icons may include Bluetooth / battery / APO
  • Jaw: trigger open/close · jaw silk left MAX 30A~ · right CAT IV 600V (priority captures raw_1/raw_2; shop_note CAT IV 300V overridden by readable jaw silk)
  • Measuring range (supplier attribute): 0 Ω ~ 2000 Ω
  • Current range (supplier attribute): 0 A ~ 1 A
  • Testing voltage (supplier attribute): 5 V
  • Insulation resistance (supplier attribute): > 1 MΩ
  • Accuracy class (supplier attribute): listed on source page as ±(0.01%+1) — treated as uncertain; not used as a selling claim
  • Power (back silk / mould): AA 1.5V ×4
  • Back marks (raw_5): CE · ETL · no model text — support image only
  • Kit / weight: confirm on this buying page (freight estimate 1.30 kg is not silk net mass)
  • Jaw opening size / loop-check steps / pass-fail limits: follow the method and supplied manual — not invented here
  • Strong contrast to UT272A (£276.51): same Earth Clamp Meter class; UT275A has MAX 30A~ + CAT IV 600V jaw silk and a combined Ω/A key — do not share photos or copy

How to take a useful reading

  1. Confirm the earth conductor / loop under test is safe to approach and that the method you are following allows a clamp-on ground-resistance (or leakage-current) check at this point. Observe the warnings in the supplied manual and jaw silk MAX 30A~ · CAT IV 600V.
  2. Select the resistance side of the combined Ω/A key for ground resistance — or the A side only when the manual allows a current / leakage-current check. Do not invent loop-test step counts or pass/fail limits on this page. Do not borrow UT521 / UT522 stake-method expectations, UT523A ρEARTH / REARTH dial paths, or UT272A’s separate Ω / A key layout as if it were this meter.
  3. Open the jaw with the trigger, seat the clamp fully around the conductor / loop, and close the jaw so the reading path is complete. Stay within jaw marking MAX 30A~.
  4. Read the English UI (10.0 Ω class on this capture). Use blue HOLD (backlight as marked), OK (Bluetooth as marked), READ, ↑ / ↓ / CLEAR and SAVE as the manual describes when you need to hold, recall, clear or store.
  5. Record path (Ω or A side), clamp point identity and the reading with the method reference. This page does not declare a legal pass/fail for the installation.

See also: UNI-T UT275A: Confirm MAX 30A~ Before You Clamp.

Specifications

  • Model: UNI-T UT275A
  • Type: Earth Clamp Meter (clamp-on ground resistance; A side per manual for current / leakage)
  • Face silk: UNI-T UT275A Earth Clamp Meter
  • English UI example: 10.0 Ω
  • Keys: orange power · blue HOLD (backlight icon) · Ω/A (combined) · ↑ · OK (Bluetooth icon) · READ · ↓ (CLEAR) · SAVE
  • Face print: FCC ID text · yellow warning triangle; screen may show Bluetooth / battery / APO
  • Jaw silk (readable on priority captures): MAX 30A~ · CAT IV 600V
  • Measuring range (supplier attribute): 0 Ω ~ 2000 Ω
  • Current range (supplier attribute): 0 A ~ 1 A
  • Testing voltage (supplier attribute): 5 V
  • Insulation resistance (supplier attribute): > 1 MΩ
  • Accuracy class (supplier attribute): source lists ±(0.01%+1) — treated as uncertain; not emphasised
  • Power: AA 1.5V ×4 (battery-door mould / silk on back)
  • Kit weight: confirm on this buying page (do not treat freight estimate as silk net mass)
  • Jaw opening / loop-check steps / pass-fail limits: follow the method you are working to and the supplied manual

Confirm batteries, case and any kit shown on this buying page before ordering. Follow the supplied manual for operating limits and safety warnings. Do not treat this page as UT275 bare, UT272A, UT278A / B, UT275+, UT521, UT522 or UT523A. Clamp geometry and loop-test schedules are not invented here — use the manual and the method you are following. Respect jaw marking MAX 30A~.

Free UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.

Get to know the UNI-T UT275A — Earth Clamp Meter layout, MAX 30A~ jaw class before you compare to UT272A, combined Ω/A path, jaw silk CAT IV 600V, and how it differs from UT275 bare / UT272A / UT278* / UT275+ / UT521 / UT522 / UT523A. Learn more →

FAQ

What does the UT275A measure?

It is a clamp-on Earth Clamp Meter for ground-resistance checks on suitable loops (resistance side of the combined Ω/A key). The A side supports current / leakage-current style checks when the supplied manual allows it. That is a different instrument class from stake-style UT521 / UT522 digital earth testers and from UT523A’s Earth-ρ dial.

How is UT275A different from UT272A?

Both are Earth Clamp Meters, but they are not the same listing. UT275A (£455.43) has jaw silk MAX 30A~ · CAT IV 600V and a combined Ω/A key. UT272A (£276.51) uses separate Ω · A keys and jaw silk CAT IV 300V on its priority captures. Do not share photos, ranges or procedures across these two models.

How is UT275A different from UT521 / UT522 / UT523A?

UT275A (£455.43) clamps the conductor / loop — English UI 10.0 Ω, jaw silk MAX 30A~ · CAT IV 600V. UT521 (£274.67) and UT522 (£294.83) are stake-style digital earth testers. UT523A (£1153.44) is an Earth-ρ Tester with ρEARTH / REARTH / EARTH VOLTAGE. Do not share photos, ranges or procedures across these models.

What is the Ω/A key on the UT275A?

Ω/A is a combined key on this face. Use the resistance side for clamp-on ground resistance (English UI Ω class on this capture). Use the A side for current / leakage-current style checks when the manual allows it. Select the side that matches the check you need before you treat a number as meaningful. Do not assume the separate Ω / A key layout from UT272A.

What does jaw silk MAX 30A~ · CAT IV 600V on the UT275A mean?

Priority captures (raw_1 / raw_2) show jaw silk left MAX 30A~ and right CAT IV 600V. Treat those as the markings on this capture and still follow all markings on the unit and the supplied manual for the installation class you are working in. Stay within MAX 30A~. This page does not invent a higher category or a whole-system rating. (Shop note recorded CAT IV 300V; readable jaw silk on disk CAT IV 600V overrides for copy.)

How is UT275A different from UT275 bare / UT278 / UT275+?

UT275A is this Earth Clamp Meter page only. UT275 bare, UT278A / B and UT275+ are different models and must not share photos or copy. Confirm face silk UT275A Earth Clamp Meter and English UI 10.0 Ω before you buy.

Does this page give jaw opening size or loop pass/fail limits?

No. Jaw opening millimetres, ring-check / loop-test step counts and legal pass/fail limits stay with the method you are working to and the supplied manual — not with this page.

What batteries does it take, and how much does it weigh?

Back mould / silk shows AA 1.5V ×4. Confirm batteries and any kit on this buying page. Instrument / kit weight is confirmed on this buying page — this page does not state a silk meter-only net mass (freight estimate 1.30 kg is not silk net weight).

Can I use HOLD and SAVE on the UT275A?

Yes — blue HOLD (with backlight icon) and SAVE are on the face, with READ, OK (Bluetooth icon), ↑ / ↓ and silk CLEAR. Use them as the supplied manual describes; this page does not invent memory-capacity or Bluetooth-range marketing claims.

Is UK delivery free?

Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. Price £455.43 incl. VAT.

In use: set up a repeatable ground observation

Use the exact tester with a visible training earth point or isolated test lead, keeping clamps and probes on the intended conductor. Show the test position and record sheet without a readable resistance value or a claim about the whole installation.

UNI-T UT275A Earth Clamp Meter ground tester positioned at an isolated earth test point
AI-generated scene illustration using product reference images: UNI-T UT275A Earth Clamp Meter ground tester positioned at an isolated earth test point. This illustrates placement and workflow, not a measured result or an included-accessory list.
FAQ

What does the UT275A measure?

It is a clamp-on Earth Clamp Meter for ground-resistance checks on suitable loops (resistance side of the combined Ω/A key). The A side supports current / leakage-current style checks when the supplied manual allows it. That is a different instrument class from stake-style UT521 / UT522 digital earth testers and from UT523A’s Earth-ρ dial.

How is UT275A different from UT272A?

Both are Earth Clamp Meters, but they are not the same listing. UT275A (£455.43) has jaw silk MAX 30A~ · CAT IV 600V and a combined Ω/A key. UT272A (£276.51) uses separate Ω · A keys and jaw silk CAT IV 300V on its priority captures. Do not share photos, ranges or procedures across these two models.

How is UT275A different from UT521 / UT522 / UT523A?

UT275A (£455.43) clamps the conductor / loop — English UI 10.0 Ω, jaw silk MAX 30A~ · CAT IV 600V. UT521 (£274.67) and UT522 (£294.83) are stake-style digital earth testers. UT523A (£1153.44) is an Earth-ρ Tester with ρEARTH / REARTH / EARTH VOLTAGE. Do not share photos, ranges or procedures across these models.

What is the Ω/A key on the UT275A?

Ω/A is a combined key on this face. Use the resistance side for clamp-on ground resistance (English UI Ω class on this capture). Use the A side for current / leakage-current style checks when the manual allows it. Select the side that matches the check you need before you treat a number as meaningful. Do not assume the separate Ω / A key layout from UT272A.

What does jaw silk MAX 30A~ · CAT IV 600V on the UT275A mean?

Priority captures (raw_1 / raw_2) show jaw silk left MAX 30A~ and right CAT IV 600V. Treat those as the markings on this capture and still follow all markings on the unit and the supplied manual for the installation class you are working in. Stay within MAX 30A~. This page does not invent a higher category or a whole-system rating. (Shop note recorded CAT IV 300V; readable jaw silk on disk CAT IV 600V overrides for copy.)

How is UT275A different from UT275 bare / UT278 / UT275+?

UT275A is this Earth Clamp Meter page only. UT275 bare, UT278A / B and UT275+ are different models and must not share photos or copy. Confirm face silk UT275A Earth Clamp Meter and English UI 10.0 Ω before you buy.

Does this page give jaw opening size or loop pass/fail limits?

No. Jaw opening millimetres, ring-check / loop-test step counts and legal pass/fail limits stay with the method you are working to and the supplied manual — not with this page.

What batteries does it take, and how much does it weigh?

Back mould / silk shows AA 1.5V ×4. Confirm batteries and any kit on this buying page. Instrument / kit weight is confirmed on this buying page — this page does not state a silk meter-only net mass (freight estimate 1.30 kg is not silk net weight).

Can I use HOLD and SAVE on the UT275A?

Yes — blue HOLD (with backlight icon) and SAVE are on the face, with READ, OK (Bluetooth icon), ↑ / ↓ and silk CLEAR. Use them as the supplied manual describes; this page does not invent memory-capacity or Bluetooth-range marketing claims.

Is UK delivery free?

Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. Price £455.43 incl. VAT.

Related instruments
Delivery & returns
When will my order arrive?

Dispatched within 1–2 working days. Delivered in 5–7 working days after dispatch.

What is the return policy?

You can return a product within 30 days. See our returns page for details.

Is checkout secure?

Payment is processed through Shopify's secure checkout.

How can I contact support?

Email support@ekodeluxe.co.uk.

UNI-T UT275A Earth Clamp Meter