PRODUCT OVERVIEW
Confirm MAX 30A~ jaw class before you compareto UT272A.
The UNI-T UT275A is a handheld Earth Clamp Meter — an instrument for clamp-on ground-resistance checks on suitable loops. Face silk reads UNI-T UT275A Earth Clamp Meter. You select the resistance side of the combined Ω/A key (or the A side when the manual allows a current / leakage-current path), close the jaw around the conductor / loop, then read the English UI. Captures show 10.0 Ω (raw_1 / raw_2). Keys: orange power · blue HOLD (backlight icon) · combined Ω/A · ↑ · OK (Bluetooth icon) · READ · ↓ (CLEAR) · SAVE; face print includes FCC ID text and a yellow warning triangle. Jaw silk on priority captures: left MAX 30A~ · right CAT IV 600V. That layout is different from stake-style UT521 / UT522 , from UT523A Earth-ρ, from near models UT275 bare / UT278* / UT275+, and from the recently published UT272A .

HOW TO APPROACH IT
An Earth Clamp Meter — not a stake-style earth tester, not an Earth-ρ Tester, and not UT272A.
The UT275A measures clamp-on ground resistance on the resistance side of Ω/A and can take a current / leakage-current style reading on the A side when the supplied manual allows it. Face silk marks Earth Clamp Meter. Use it when you need a dedicated clamp-on earth meter with English UI 10.0 Ω and jaw silk MAX 30A~ · CAT IV 600V — not as UT521 / UT522, not as UT523A, not as UT272A, and not as UT275 bare / UT278 / UT275+. This overview does not invent jaw opening size, ring-check step counts or pass/fail limits; follow the method you are working to and the supplied manual. Respect MAX 30A~.
Confirm MAX 30A~ before you compare to UT272A
Before you compare price or procedure to UT272A, read the face silk UT275A Earth Clamp Meter and confirm jaw silk MAX 30A~ · CAT IV 600V. UT272A is also an Earth Clamp Meter, but it is a different listing — separate Ω / A keys, jaw silk CAT IV 300V on its priority captures, different price. UT521 / UT522 drive stakes; UT523A is an Earth-ρ Tester. UT275A clamps the loop under MAX 30A~.
Set Ω/A (resistance or A side) before you treat the number as meaningful
Select the resistance side of Ω/A for ground resistance — or the A side only when the manual allows a current / leakage-current check — before you rely on the display. Use HOLD, READ, SAVE, OK and ↑ / ↓ / CLEAR as the manual describes. Do not assume UT272A’s separate Ω / A key layout.
Close the jaw fully, stay within MAX 30A~, then read / HOLD / SAVE
Open the jaw with the trigger, seat the clamp around the conductor / loop, close fully, respect MAX 30A~, then read the English UI (10.0 Ω class). Respect jaw silk CAT IV 600V. Record path (Ω or A side) and clamp-point identity with the reading.
WHY THE METHOD MATTERS
Make the MAX 30A~ jaw class part of the comparison.
Confirm MAX 30A~ · CAT IV 600V and the combined Ω/A key before you treat UT275A and UT272A as interchangeable.

TYPICAL TASKS
Where this clamp earns its place.
Screen after setup
Confirm the Ω/A side in use and that the English UI matches the path you chose (10.0 Ω class) before you treat a figure as meaningful.
Record path with the reading
Note whether you used the resistance or A side, the clamp-point identity and the date with every stored value. Use HOLD / SAVE / READ as the manual describes.
Keep model identity clear
Stay on UT275A — do not borrow UT272A, UT275 bare, UT278* / UT275+, or stake-style UT521 / UT522 / UT523A photos, ranges or procedures.
FIT CHECK
Is this the right shortlist?
A good shortlist for
- Clamp-on ground-resistance checks on suitable loops under MAX 30A~
- Jobs that need English UI 10.0 Ω class with combined Ω/A
- Teams that must keep UT275A distinct from UT272A and stake-style earth testers
Check these limits first
- Not a stake-style digital earth tester (≠ UT521 / UT522)
- Not an Earth-ρ Tester (≠ UT523A)
- Not UT272A / UT275 bare / UT278* / UT275+
- Do not invent jaw opening size, loop-test step counts or pass/fail limits
- Respect jaw silk MAX 30A~ · CAT IV 600V
- Confirm kit / weight on the buying page (freight 1.30 kg ≠ silk net mass)
| What matters | UNI-T UT275A |
|---|---|
| Instrument class | Earth Clamp Meter (clamp-on) |
| Face silk | UNI-T UT275A Earth Clamp Meter |
| English UI example | 10.0 Ω |
| Path key | Combined Ω/A |
| Jaw silk | MAX 30A~ · CAT IV 600V |
| Vs UT272A | Different jaw / keys / price — not interchangeable |
Values above follow this capture’s face silk / English UI and the EkoDeluxe listing. Confirm the live unit and supplied manual before you work.
| Specification | UNI-T UT275A |
|---|---|
| Model | UNI-T UT275A |
| Type | Earth Clamp Meter |
| English UI example | 10.0 Ω |
| Keys | Orange power · HOLD · Ω/A · ↑ · OK · READ · ↓ (CLEAR) · SAVE |
| Jaw silk | MAX 30A~ · CAT IV 600V |
| Measuring range (supplier) | 0 Ω ~ 2000 Ω |
| Current range (supplier) | 0 A ~ 1 A |
| Testing voltage (supplier) | 5 V |
| Insulation resistance (supplier) | > 1 MΩ |
| Power | AA 1.5V ×4 |
| Face print | FCC ID · yellow warning triangle |
| Back marks | CE · ETL (raw_5) |
| SKU | EKO-UT275A |
| UK price | [see buying page] |
| Weight | Confirm on buying page (freight est. 1.30 kg) |
Shipping weight used in store is 1.30 kg (freight estimate — not silk net mass). For operating details beyond supplier attributes, use the supplied manual. Accuracy class on the source page is treated as uncertain and is not used as a selling claim.
GET THE CONTEXT
Learn before you choose.
Start with the model-specific how-to, then open the buying page for kit and price.
Confirm MAX 30A~ · CAT IV 600V, set Ω/A before you read, close the jaw, use HOLD / SAVE — keep UT275A distinct from UT272A and stake-style earth testers.
Read the guide → BUYING PAGEUNI-T UT275A Clamp MeterConfirm price and kit on the buying page. VAT included, free UK delivery. Confirm the current kit before ordering.
View product →A FEW MORE DETAILS
Your questions, answered.
What does the UT275A measure?
It is a clamp-on Earth Clamp Meter for ground-resistance checks on suitable loops (resistance side of the combined Ω/A key). The A side supports current / leakage-current style checks when the supplied manual allows it. That is a different instrument class from stake-style UT521 / UT522 digital earth testers and from UT523A’s Earth-ρ dial.
How is UT275A different from UT272A?
Both are Earth Clamp Meters, but they are not the same listing. UT275A has jaw silk MAX 30A~ · CAT IV 600V and a combined Ω/A key. UT272A uses separate Ω · A keys and jaw silk CAT IV 300V on its priority captures. Do not share photos, ranges or procedures across these two models.
How is UT275A different from UT521 / UT522 / UT523A?
UT275A clamps the conductor / loop — English UI 10.0 Ω, jaw silk MAX 30A~ · CAT IV 600V. UT521 and UT522 are stake-style digital earth testers. UT523A is an Earth-ρ Tester with ρEARTH / REARTH / EARTH VOLTAGE. Do not share photos, ranges or procedures across these models.
What is the Ω/A key on the UT275A?
Ω/A is a combined key on this face. Use the resistance side for clamp-on ground resistance (English UI Ω class on this capture). Use the A side for current / leakage-current style checks when the manual allows it. Select the side that matches the check you need before you treat a number as meaningful. Do not assume the separate Ω / A key layout from UT272A.
What does jaw silk MAX 30A~ · CAT IV 600V on the UT275A mean?
Priority captures (raw_1 / raw_2) show jaw silk left MAX 30A~ and right CAT IV 600V. Treat those as the markings on this capture and still follow all markings on the unit and the supplied manual for the installation class you are working in. Stay within MAX 30A~. This page does not invent a higher category or a whole-system rating. (Shop note recorded CAT IV 300V; readable jaw silk on disk CAT IV 600V overrides for copy.)
Ready to buy the UNI-T UT275A?
UK stock, VAT included, free UK delivery. SKU EKO-UT275A.
Product information: UNI-T face markings / manufacturer-style attributes and the EkoDeluxe product listing. Overview checked 3 November 2026. For operating instructions, use the supplied manual. Model UNI-T UT275A · SKU EKO-UT275A.