

UNI-T UT206A+ Clamp Meter
The UNI-T UT206A+ is a digital clamp meter for 1000 A AC with a 6000-count display. Face silk: UNI-T, UT206A+, 1000A AC Clamp Meter, 6000 Counts. The rotary clamp-current position is labelled Inrush 1000A~, with dial NCV Lo Hi for non-contact voltage prompting. Jaw / face safety markings include CAT III 600 V and CAT II 1000 V, with jaw current silk 1000 A. English UI example on the display: 6.099 / DC / V / AUTO. Lead / dial paths cover AC voltage / frequency, the ohms family, capacitance, frequency / duty and temperature (°C / °F). Face keys: SELECT, REL (with backlight) and Max / Min, plus a side HOLD. UK price , free delivery.
Not bare UT206 / UT206A (same-batch HOLD — do not list), not UT206C (pending), not UT205A+ (, 4000 counts, no Inrush / NCV silk on that face), not UT205 / UT205A / UT205E. This page is the UT206A+ only — a 1000 A AC clamp with 6000 counts, dial Inrush 1000A~ and NCV Lo Hi, English UI 6.099 / DC / V / AUTO, face SELECT / REL / Max Min, and jaw / face markings CAT III 600 V / CAT II 1000 V. Do not use 205A+ / 206 / A / C co-branded images or another UT206-series photo for ranges or accessories.
1000 A AC clamp with 6000 counts, Inrush 1000A~, NCV and English UI 6.099 / DC / V / AUTO
The UT206A+ suits single-conductor AC current and inrush checks on the Inrush 1000A~ dial position when the expected load sits inside the listed span. The English display example shows 6.099 with DC, V and AUTO — that is a DC / voltage / auto-range UI style on this face, not a clamp-amps or inrush reading by itself. Dial NCV Lo Hi prompts for AC electric field presence; it does not prove isolation. Lead and dial functions extend to AC voltage / frequency, the ohms family, capacitance, frequency / duty and temperature. Follow the manual for SELECT, REL, Max / Min, side HOLD, Inrush behaviour, NCV behaviour, category limits and lead use. No True RMS silk is claimed on this page — do not invent one from sibling models.
- AC current / inrush: rotary Inrush 1000A~ (jaw silk 1000 A)
- Display class: 6000 counts (face silk 6000 Counts; English UI example peaking at 6.099)
- Face silk: UNI-T · UT206A+ · 1000A AC Clamp Meter · 6000 Counts
- Safety markings (jaw / face on this exact capture): CAT III 600 V · CAT II 1000 V
- English UI example: display 6.099 with DC · V · AUTO
- Rotary dial includes: OFF · NCV Lo Hi · Hz / V~ · Ω / diode / continuity / capacitance · Hz % · °C / °F · Inrush 1000A~
- Face keys: SELECT · REL (backlight) · Max / Min
- Side control: HOLD (torch / flashlight icon as on this capture)
- Inputs: COM and VΩHz measurement jack as marked on the face
- Battery (rear door silk on this capture): 2 × 1.5 V AAA
- Product weight (listing attribute): 240 g (0.24 kg)
- This model lists AC current on the clamp — it is not a DC-current clamp
- No True RMS claim on this page — do not copy True RMS wording from UT216* / UT213B / UT200* pages
How to set Inrush before you read the peak
- Confirm the expected AC current / starting surge against the listed 1000 A AC span, then turn the dial to Inrush 1000A~ only when access is safe — Max / Min or a frozen peak does not mean “any dial position is already an inrush reading”.
- Treat a screen example showing 6.099 / DC / V / AUTO as a DC / voltage / auto-range UI style on this face, not as proof that the jaw is already reading amps or capturing inrush.
- Clamp a single suitable conductor — not an entire twin-and-earth or both go-and-return paths together.
- Wait for a stable reading; use face Max / Min or REL only as the manual describes for the function you selected, and side HOLD if you need to step away from the conductor to note the value. Follow the manual for how Inrush captures the starting surge on this model.
- Match the installation to the jaw / face markings CAT III 600 V / CAT II 1000 V on this exact meter — a 1000 A current span does not replace category matching. Treat dial NCV Lo Hi as a prompt only, never as isolation proof.
See also: UNI-T UT206A+: Set Inrush Before You Read the Peak.
Specifications
- Model: UNI-T UT206A+
- Type: digital clamp meter (1000 A AC · Inrush)
- Display counts: 6000
- Face silk: UNI-T · UT206A+ · 1000A AC Clamp Meter · 6000 Counts
- AC current / inrush: listed 1000 A AC on Inrush 1000A~
- NCV: dial NCV Lo Hi (prompt only — not isolation proof)
- Display UI (English example): 6.099 / DC / V / AUTO
- Lead / dial functions: AC voltage / frequency, resistance / diode / continuity, capacitance, frequency / duty (Hz %), temperature (°C / °F)
- Controls: SELECT, REL (backlight), Max / Min; side HOLD
- Safety markings (jaw / face on this exact capture): CAT III 600 V · CAT II 1000 V
- Inputs: COM and VΩHz measurement jack as marked on the face
- Battery (rear door silk on this capture): 2 × 1.5 V AAA
- Product weight (listing attribute): 240 g
- Current method: AC clamp only (no DC current range on this model)
- True RMS: not claimed on this page — do not invent
Confirm leads, any hard case / kit shown on this buying page and the English manual before ordering. Follow the supplied manual for accuracy conditions, Inrush timing behaviour, NCV behaviour and measurement-category suitability. Do not treat this page as UT206, UT206A, UT206C, UT205A+, UT205, UT205A, UT205E, UT216A/B/C or UT200A+/UT200B+. Jaw opening size and numeric accuracy tolerances are not invented here — use the manual and the markings on your unit.
Free UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.
Get to know the UNI-T UT206A+ — 1000 A AC, 6000 counts, Inrush 1000A~, NCV, English UI 6.099 / DC / V / AUTO, CAT III 600 V markings and model distinctions before you choose. Learn more →
FAQ
What AC current does the UT206A+ list?
Listed 1000 A AC on the rotary Inrush 1000A~ position, with jaw silk 1000 A. It is a 1000 A AC clamp with an Inrush path, not a DC-current clamp and not the UT205A+ / bare UT206 layout.
What does Inrush 1000A~ do on this meter?
It is the rotary clamp-current / inrush position silk-printed on this exact face. Set Inrush 1000A~ before treating a peak or Max/Min value as a starting-surge reading. Follow the supplied manual for capture timing and accuracy conditions — do not invent Inrush behaviour from sibling pages.
What does the English UI 6.099 / DC / V / AUTO mean on this page?
It is the English display example on this exact face — a DC / voltage / auto-range readout style. It is not a screen-size claim and not, by itself, a clamp-amps or inrush reading. Set Inrush 1000A~ before treating the jaw path as AC current.
Does NCV prove a circuit is safe / isolated?
No. Dial NCV Lo Hi is a non-contact voltage prompt only. It does not prove isolation, does not measure amps, and does not authorise live work. Use the correct safe-isolation equipment and procedure for the installation.
Does it measure DC current? Is it True RMS?
No DC current clamp range is listed on this model — it is a 1000 A AC clamp (Inrush 1000A~). No True RMS claim is made on this page from face silk. Do not copy True RMS wording from UT216*, UT213B or UT200* pages. Follow the manual’s accuracy conditions for the function and range you select.
How is UT206A+ different from UT205A+ and from UT206 / UT206A / UT206C?
This page is UT206A+ only. Confirmed differences vs UT205A+ include 6000 counts (vs 4000), dial Inrush 1000A~ and NCV Lo Hi (UT205A+ face uses 1000 A~ without Inrush / NCV silk on that capture), English UI 6.099 / DC / V / AUTO (vs 4.099 / DC / AUTO), and temperature °C / °F on this dial. Bare UT206 / UT206A are same-batch HOLD (do not list or borrow their photos). UT206C is pending — do not use A/C combo posters. Price on this page: .
Is UK delivery free?
Yes. Free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch.
Learn more
Read the UNI-T UT206A+ overview and the field guide Set Inrush Before You Read the Peak.
Technical specifications
| Specification | Value |
| Model | UNI-T UT206A+ |
| SKU | EKO-UT206A+ |
| AC current (listed max) | 1000 A AC |
| Inrush | Inrush 1000A~ (rotary / face) |
| Display class | 6000 Counts |
| English UI example | 6.099 / DC / V / AUTO |
| NCV | Lo Hi (dial) |
| True RMS | Not claimed |
| CAT (this capture) | CAT III 600 V / CAT II 1000 V |
| Jaw current silk | 1000 A |
| Face keys | SELECT, REL (backlight), Max / Min; side HOLD |
| Power | 2 × 1.5 V AAA |
| Product weight | 240 g (0.24 kg) |
Does the UNI-T UT206A+ claim True RMS?
No. This page does not claim True RMS silk. Do not copy True RMS wording from UT216*, UT213B or UT200* pages.
What AC current and inrush span is listed?
Listed max is 1000 A AC. The rotary clamp-current position is labelled Inrush 1000A~, with jaw current silk 1000 A.
Is NCV proof of isolation?
No. Dial NCV Lo Hi is a non-contact voltage prompt only. Confirm de-energised state with an appropriate contact method and safe work practice.
What CAT markings are on this capture?
Jaw / face silk on this exact unit includes CAT III 600 V and CAT II 1000 V. A 1000 A span does not upgrade the category.
How is UT206A+ different from UT205A+?
UT206A+ is a 1000 A AC / 6000-count clamp with Inrush 1000A~ and NCV Lo Hi on this face. UT205A+ is a different listing (4000 counts) without those Inrush / NCV silk claims on its shortlist.
What batteries does it take?
Rear door silk on this capture: 2 × 1.5 V AAA. Fit the polarity shown in the compartment.
When will my order arrive?
Dispatched within 1–2 working days. Delivered in 5–7 working days after dispatch.
What is the return policy?
You can return a product within 30 days. See our returns page for details.
Is checkout secure?
Payment is processed through Shopify's secure checkout.
How can I contact support?
Email support@ekodeluxe.co.uk.


