Basket

PRODUCT OVERVIEW

Treat NCV as a prompt.Clamp one conductor.

The UNI-T UT213B is a True RMS digital clamp meter for 400 A AC with a 4000-count display. Face silk reads UNI-T UT213B, True RMS 4000 Counts, 400A AC Digital Clamp Meter and CAT III 600V. An English UI example on the display shows 0.000 / AC / A / AUTO. Rotary positions include A~, voltage, ohms family, °F °C, Hz% and NCV. It is a different model from UT213A, UT213C, UT210E, UT200A+ and UT200B+.

UNI-T UT213B Clamp Meter
400 AListed AC current max
4000 CountsFace display class
True RMSListed AC response
NCVDedicated dial + indicator

HOW TO APPROACH IT

An AC clamp with NCV and temperature on the dial.

Physical fit and the documented current method both matter. The UT213B lists lead and dial measurements for AC/DC voltage, resistance / diode / continuity / capacitance, temperature, frequency/duty and NCV, plus HOLD, MAX MIN and REL on a handheld body powered by 3 × AAA. AC current is selected on A~ — it is not a DC-current clamp.

01

Match one suitable conductor

The jaw must close fully around a single conductor of interest. Clamping go-and-return together can cancel the field and produce a near-zero result that does not mean “no current”.

02

Keep NCV in proportion

The NCV dial position and face indicator are prompts to investigate with the proper method. They are not proof of isolation and not a substitute for a proving unit or safe-isolation steps under the CAT III 600 V face marking.

03

Use SELECT, MAX MIN and REL only as documented

True RMS applies to the listed AC paths when the waveform is not a clean sine. HOLD freezes a reading; MAX MIN and REL behave as the manual describes for the function on the dial — do not invent modes that the silk does not support.

WHY THE METHOD MATTERS

Match current type and indication aids to the job.

Treat NCV as a prompt → set A~ → clamp one conductor → use HOLD / MAX MIN / REL only as documented.

UNI-T UT213B rear battery bay 3×AAA

TYPICAL TASKS

Where this clamp earns its place.

Plan an AC current check

Confirm expected current against the listed 400 A AC span, set A~, and verify safe access before the jaw closes.

Take a supported voltage, ohms or temperature reading

Use the supplied leads (and any documented temperature probe for °F °C) and the documented input limits. A CAT III 600 V face marking does not establish every installation category by itself.

Prepare the portable kit

Confirm three AAA cells, leads, torch/worklight behaviour and the English manual on the buying page.

FIT CHECK

Is this the right shortlist?

A good shortlist for

  • Users who need a True RMS 400 A AC clamp with a 4000-count face and English UI.
  • Tasks that stay on AC current and may benefit from dial NCV, temperature (°F °C) and Hz% — without needing DC current on the clamp.
  • Buyers who will confirm single-conductor technique, NCV limits and category markings before purchase.

Check these limits first

  • Do not invent a DC current span — this model is listed as a 400 A AC clamp.
  • Do not invent a 1000 A span, jaw millimetres, accuracy percentages or Inrush unless the supplied manual states them.
  • NCV is not isolation proof.
  • Screen value 0.000 is an English UI readout example, not a screen-size claim.
  • CAT III 600 V is the face / jaw marking — still match leads and competent procedure to the job.
  • This page is not UT213A, UT213C, UT210E, UT200A+ or UT200B+.
What matters UNI-T UT213B
Main role True RMS AC clamp + lead / dial measurements
Current AC only · listed 400 A AC (A~)
Display 4000 counts · English UI example 0.000 / AC / A / AUTO
Safety face marking CAT III 600 V
Notable controls SELECT, HOLD, MAX MIN, REL, NCV, °F °C, side torch
A reason to shortlist it You need a 400 A AC True RMS clamp with NCV, temperature dial and English UI

Compare UT213A, UT213C, UT210E, UT200A+ or UT200B+ only from their own datasheets and product pages — current methods, counts and accessories differ. Do not use factory A/B/C combo posters for this overview.

Specification UNI-T UT213B
Model UT213B
Type True RMS digital clamp meter (400 A AC)
Display counts 4000
AC current Listed 400 A AC (A~ dial)
Display UI (example) 0.000 / AC / A / AUTO
Lead / dial functions V~, V⎓, Ω / diode / continuity / capacitance, °F °C, Hz%, NCV
Controls SELECT, HOLD / backlight, MAX MIN, REL; side torch
Safety marking (face + jaw) CAT III 600 V
Power 3 × 1.5 V AAA
Current method AC clamp only (no DC current range)

Specifications describe the reviewed UNI-T UT213B face silk, jaw silk and listing sources. Follow the supplied manual for accuracy conditions and operating limits. Confirm the current kit on the buying page (£95.17) before ordering.

GET THE CONTEXT

Learn before you choose.

Start with the model-specific how-to, then open the buying page for kit and price.

A FEW MORE DETAILS

Your questions, answered.

Can it measure DC current?

No. UNI-T lists this model as a 400 A AC clamp. DC on the dial is V⎓ for DC voltage lead work, not clamp DC current.

Does it have True RMS and 4000 counts?

Yes. Both are face markings on this UT213B. Check the manual’s accuracy conditions for the waveform and function you intend to measure.

Is NCV always required?

No. Use NCV only as the manual describes for indication. It is not a default substitute for safe isolation.

Is this UT213A, UT213C or UT210E?

No. UT213B is a separate model. Do not apply A/C combo posters or UT210E AC/DC mini-clamp specifications to this overview.

Ready to buy the UNI-T UT213B?

UK stock, VAT included, free UK delivery. SKU EKO-UT213B.

Buy · £95.17

Product information: UNI-T face markings / manufacturer-style attributes and the EkoDeluxe product listing. Overview checked 3 November 2026. For operating instructions, use the supplied manual. Model UNI-T UT213B · SKU EKO-UT213B.