ZOYI ZT-703S: Compare Two Signals with One Reference Plan

The ZOYI ZT-703S combines a 50MHz dual-channel oscilloscope, a 25000-count True RMS multimeter and a signal generator. Two scope channels are useful for comparing timing, provided you plan their references before atta...

By EkoDeluxe · Published · Updated

ZOYI ZT-703S product view

The ZOYI ZT-703S combines a 50MHz dual-channel oscilloscope, a 25000-count True RMS multimeter and a signal generator. Two scope channels are useful for comparing timing, provided you plan their references before attaching the probes.

Two inputs do not establish two independently isolated measurement systems. The reference arrangement is part of the experiment, especially when another powered instrument or computer is connected.

ZOYI ZT-703S product view

ZOYI ZT-703S supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.

Sketch the two signals and their references

For an appropriate isolated low-voltage circuit, mark the two intended signal points and the permitted common reference. Check the exact-model documentation for input relationships, reference connections, voltage limits and the effect of charging or other external connections.

The “ground clip” question in electronics discussions is useful here: a probe's reference connection can alter the circuit, rather than merely giving the screen a zero. Do not place two reference clips on different arbitrary points on the assumption that the channels are isolated. Battery operation alone does not establish safe floating capability.

ZT-703S front connections and controls

Supplier control-layout illustration; verify the exact supplied instructions.

Make both channels comparable

Check each compatible probe's attenuation setting against the channel setting. Establish a stable trigger and choose time and voltage scales that show the relationship you actually need. Use suitable probe compensation where required by the probe and instrument instructions.

A simple first experiment is to observe the same known low-voltage repeating signal on both channels. That provides a check of the setup before moving to two different points. Account for the probes, cables and channel settings if a small timing difference matters; a mismatch can belong to the measurement arrangement.

Two signals need a reference plan. SIGNAL A: Named point and probe. SIGNAL B: Named point and probe. REFERENCE: Verify the permitted common connection

Two channels do not establish isolated inputs.

Save the reference plan with the trace

Record which physical point belongs to each channel, the reference location, probe attenuation, scales, trigger source and circuit state. A colour-coded trace is much easier to interpret when its colour is tied to a named point rather than remembered after the leads have moved.

Suppose an illustrative pair of signals repeats every 1ms and one identifiable edge occurs 0.1ms later than the other. That is a time relationship in that experiment, not evidence of a device fault. Establish whether you mean propagation delay, phase of a repeating signal or simply different events before interpreting it.

The signal generator and multimeter add other possible tests, but each needs its own allowed connection arrangement. Do not leave an active generator connected merely because you have changed to a measurement screen.

The ZT-703S becomes especially useful when the saved waveform includes enough information to rebuild the experiment. Plan the reference first, then let the second channel answer a clearly defined timing question.

For the current specification and supplied version, see the ZOYI ZT-703S product page.