The ZOYI ZT-225 is listed as a 25000-count True RMS multimeter with a current range up to 20 A. That headline can attract anyone working on higher-current equipment, but it does not say that 20 A may be measured continuously or through every lead and connection in a kit.
Before choosing a multimeter for a current task, establish the permitted duration, terminal protection, lead ratings and connection method. Those details are as important as the upper range value.

Current measurement changes the connection
A conventional multimeter current function is normally inserted in the current path under the appropriate procedure. It is not connected across a source in the way a voltage measurement is. A current input can present a low-resistance path, so leaving a lead in that socket before a later voltage check creates a serious risk.
Use the exact model's instructions and appropriately rated equipment. Do not begin with a high-current battery or mains circuit as a learning exercise. Low voltage alone does not mean a source cannot deliver hazardous fault current.
Ask for the missing operating conditions
The ZT-225 listing establishes the 20 A upper range but does not give a complete permitted-duration and cool-down table. Obtain that information before planning a measurement near the limit. Do not infer continuous capability from a brief marketing phrase.
Also confirm the correct fuse specification and input limits. Replacing a fuse with a different type or bypassing it is not a way to extend a meter's capability. The instrument, leads and connection arrangement must all be suitable for the task.

Account for the meter's effect on the circuit
An inserted current-measuring path has some voltage drop, often discussed as burden voltage. In a sensitive low-voltage circuit, that drop can change the circuit's behaviour. The displayed current may therefore describe the circuit with the meter inserted, rather than precisely the original arrangement.
This does not make direct current measurement useless. It means the method must suit the question. Where appropriate, a suitable clamp or other measurement method may avoid breaking the current path, but it brings its own range, resolution and bandwidth requirements.
Separate True RMS from current duration
True RMS describes measurement of an effective AC value within specified conditions. It does not relax the thermal or electrical limits of a current input. The relevant waveform and frequency conditions still need to be checked.
The 25000-count display similarly describes available display capacity, not a universal accuracy level. A detailed readout does not establish that a high-current connection is safe or that a brief peak was captured correctly.
Plan the end of the measurement
A good procedure includes how to restore the circuit safely and return the leads to the appropriate storage or voltage-measurement arrangement. Record the measurement duration and operating state alongside the value where they matter.
If a DMM reading changes after insertion, investigate whether the connection, source or meter burden has changed the circuit. Do not immediately interpret the difference as a device fault.
The ZT-225 can be evaluated as a higher-current-range multimeter once these conditions are known. Its 20 A label should begin the specification check, not end it.

See the ZOYI ZT-225 product page for the current version and kit, or read the ZOYI ZT-225 overview before choosing.