The ZOYI ZT922S folds into a compact body with integrated probe storage. That design is useful when a meter moves between a home workbench, a tool bag and a small repair space. Its practical advantage depends on keeping the leads protected and the setup easy to recognise each time it is opened.
A tidy kit should make a correct measurement easier, not conceal damaged leads or leave the user guessing which function is active.

Pack around the actual work
The ZT922S listing includes AC/DC voltage, resistance, continuity, diode, capacitance, frequency/duty cycle and temperature functions, plus NCV, HOLD and REL. Decide which of those you need during a mobile session and bring the appropriate confirmed accessories.
Do not assume the fold-out body contains every probe required for every function. Check the current package and the instructions for a compatible temperature probe or other accessory. The faceplate's 600 V maximum is a limit, not a substitute for checking category, function and environment suitability.
Open, inspect and position before connecting
Inspect the body, probe insulation and tip condition before use. Release the leads from storage without pulling sharply on the cable. Position the meter so the display can be read without tension in the leads or an unstable balance on the edge of the bench.
Use an appropriate low-voltage, unpowered or isolated task while learning the layout. Keep test points visible and avoid balancing the meter against conductive objects. A convenient folding stand does not establish that every opening angle is mechanically stable.

Label the two readings
The English interface can show a dual readout, such as DC voltage and temperature. Identify both quantities and their units. A secondary temperature value is not automatically the temperature of the component being probed; the applicable sensor and connection determine what it represents.
If using HOLD, remember that the value may remain after the probes move. If using REL, preserve the reference that was zeroed. Those controls can be helpful on a cramped bench, but the next person needs to know whether they are seeing an absolute, relative or held observation.
Check the “beep” on its own terms
Continuity is useful for suitable unpowered checks, but a beep reflects the meter's threshold and response behaviour. It does not establish a zero-resistance connection or prove a wire can carry its intended current.
If a brief contact produces an unexpected sound, repeat a controlled check under the instructions and examine the resistance where appropriate. Community discussion of continuity latching is a reminder that audible behaviour can differ between meters. It is not evidence that the ZT922S implements any particular latching algorithm.
Close the kit deliberately
End the measurement safely, disconnect and return the meter to the storage state specified by the manufacturer. Place the leads into their intended slots without pinching insulation at the hinge or forcing a tight bend. Protect exposed tips from other items in the bag.
Keep a small record of any damage, intermittent connection or unusual behaviour instead of packing the problem away for the next visit. Replace or service unsuitable equipment through the proper route.
The ZT922S's compact form is most valuable when it supports a repeatable opening and closing routine. A portable kit that preserves lead condition and makes the display state obvious is easier to trust than one that is simply small.

See the ZOYI ZT922S product page for the current version and kit, or read the ZOYI ZT922S overview before choosing.