The VICTOR VC923E listing gives CAT III 600 V for the input rating and separately marks the mA/A terminal at a maximum of 10 A/250 V. Those statements must stay attached to the connection they describe. The larger voltage marking is not permission to use every terminal in every circuit.
This distinction is worth understanding before using the meter's SMART mode or relying on its large dual display. Automatic identification cannot make an unsuitable physical connection safe.

The socket is part of the measurement function
Voltage and current measurements use different arrangements. A current input is normally part of the current path under the relevant procedure, whereas voltage is observed across points. Connecting a current input across a source can create a low-resistance path.
Before connecting, identify the intended quantity, appropriate sockets and lead positions. Check the exact manual for range, fuse, duration and circuit limits. Do not assume SMART mode can detect and correct a lead inserted into an unsuitable socket.
Keep the two limits visible
The listing's 10 A/250 V current-terminal statement is not interchangeable with CAT III 600 V. It also does not establish continuous 10 A operation or every permitted current-measurement environment. Those details need the model-specific instructions.
The leads and accessories must be suitable too. A meter's category marking does not upgrade an unrated probe, damaged insulation or an improvised adapter. The complete setup must match the work.

Use a connection check at each change of task
Switching from a current task to a voltage task is a common moment for a socket error. End the first measurement safely and follow the procedure for reconfiguring the meter before moving the probes to the next circuit.
A brief spoken or written check can help: intended quantity, lead sockets, selected function, displayed unit and applicable limit. That is more dependable than relying on the previous task's setup because the display still looks familiar.
For learning, use suitable isolated low-voltage exercises under competent guidance. Do not practise current connections on a high-current battery, mains circuit or unknown supply.
Understand the other screen information
The VC923E lists 6000 counts, True RMS, dual readings and several electrical and temperature functions. Counts describe the display; True RMS remains subject to waveform and frequency conditions. Neither feature changes the input protection limits.
HOLD can retain a value after conditions change. Verify that the screen is live when a current observation is needed, and preserve the context of a held reading. A large display is helpful only when its mode and unit are correctly understood.
Keep NCV and Live indications supplementary
The product lists NCV and Live wire detection. These indications are not a replacement for an approved isolation and proving-dead procedure. A quiet indication cannot make a conductor safe to touch.
The community shorthand DMM can make multimeters sound interchangeable, but their terminals, limits and protections differ. The VC923E's specific markings should govern the setup, rather than a habit learned on another meter.
A useful measurement record includes the function and connection used, not just the number. That preserves the distinction between a valid reading and a number obtained through an unsuitable terminal arrangement.

See the VICTOR VC923E product page for the current version and kit, or read the VICTOR VC923E overview before choosing.