Basket

multimeter · Guide

UNI-T UT136C+: Confirm Temp Probe — Not a UT136B+ NCV Co-Sell

Keep UNI-T UT136C+ distinct from UT136B+: confirm face silk, set °C°F or the measurement path, seat leads / probe, then read / HOLD. No NCV on this C+ capture.

By EkoDeluxe · Published · Updated

How to keep the UNI-T UT136C+ digital multimeter distinct from UT136B+ co-sells and near DMM models: confirm UT136C+ silk, set temperature °C°F or the measurement path deliberately, seat leads or the temperature probe correctly, then read / HOLD.

By EkoDeluxe · Published 3 November 2026 · Updated 3 November 2026

On this page Confirm the method, UT136C+ identity, and a safe approach first · Set °C°F — or the measurement path — then probe and read · SELECT / HOLD — then clear as the manual describes · Keep model identity clear — stay on UT136C+ · Record enough context to reuse the number

Comparing UT136C+ to a UT136B+ street card — or probing before you set the dial path — without checking the face silk is the usual mistake. The UNI-T UT136C+ is a handheld digital multimeter with 3999/4000-count class (face mark 4000 Count), keys SELECT · HOLD / backlight (no MAX/MIN), a dedicated °C°F dial position (no NCV on this face), and body silk CAT II 1000V / CAT III 600V. Before you treat a voltage, current or temperature reading as meaningful — or reuse a procedure written for UT136B+ / bare UT136 / UT136+ cage / UT890D+ / UT61E+ — confirm UT136C+ silk, set the dial path, seat the leads or probe, then read / HOLD / SELECT.

A neat display capture does not repair a run started under UT136B+ NCV expectations, under bare UT136 / UT136+ cage expectations, or under UT890D+ / UT61E+ procedures. If a listing or poster shows UT136C+ beside UT136B+, confirm the face silk UT136C+ and the °C°F dial (blank NCV on this C+ capture) before you buy — do not borrow another model’s ranges or photos, and do not use a comparison chart as the hero.

Confirm the method, UT136C+ identity, and a safe approach first

  1. Confirm the circuit or surface under test is safe to approach and that the method you are following allows a probe check or a temperature reading at this point.
  2. Read the warnings in the supplied manual before you probe. Respect all CAT / fuse markings on the unit (CAT II 1000V / CAT III 600V, fused 400 mA / 10 A as marked).
  3. This guide does not invent fuse schedules, thermocouple grades or legal pass/fail limits. Follow the method you are working to and the supplied manual.
  4. This guide does not declare a legal pass/fail for the installation. Record what the instrument shows under the method you are following.

A stored reading without path context is hard to defend later.

Set °C°F — or the measurement path — then probe and read

  1. Read face silk UT136C+. Do not treat this as a UT136B+ co-sell, as bare UT136, as a UT136+ series cage, as UT890D+, or as UT61E+.
  2. Power on. For temperature checks, select dedicated °C°F as the supplied manual describes — before you rely on a number. For voltage / current / resistance / capacitance / Hz / hFE paths, pick the matching dial position first. Do not assume UT136B+ NCV soft-key layouts or an NCV dial that this face does not have.
  3. Seat leads or the temperature probe in the correct jacks (COM · VΩ…°C°F · 10A as required). Respect fused limits printed on the face.
  4. Keep the same path when you compare points on the same job.
  5. Do not invent fuse schedules or pass/fail numbers on this page — those stay in the method / manual.

Wrong path, a borrowed UT136B+ NCV layout, or ignoring UT136C+ identity, make the reading meaningless for your comparison. A temperature reading is not a full process certificate.

SELECT / HOLD — then clear as the manual describes

  1. Read the display for the path you set.
  2. Note path, jack / probe identity and date with the reading. Use HOLD when you need to freeze a value; use SELECT as the manual describes; use backlight on the blue key as marked (>2 Sec). This capture has no MAX/MIN key.
  3. Allow any safe lead-removal steps the manual requires before you leave the circuit.
  4. Operating tables beyond the face markings listed on the buying page are not invented here — confirm detail in the supplied manual.

Keep model identity clear — stay on UT136C+

This page is UT136C+ only — a digital multimeter with temperature °C°F and body CAT II 1000V / CAT III 600V, and no NCV on this capture — not a UT136B+ co-sell, not bare UT136, not a UT136+ series cage, not UT890D+, and not UT61E+. Different suffixes and near letters bring different layouts and workflows. Confirm UT136C+ on the face before you reuse a procedure written for another model, and never paste UT136B+ / bare UT136 / UT136+ / UT890D+ / UT61E+ combo photos onto this guide’s gallery. Comparison charts stay off the hero; raw_6 rear cover (no model text) is not a sole model lock.

Record enough context to reuse the number

Keep with each reading: dial path, jack / probe identity, date, and the displayed value. A stored value without that context is hard to defend later.

Price is only on the buying page / Markets catalog — this guide does not hardcode GBP/EUR amounts. For operating instructions, use the supplied manual. Model UNI-T UT136C+ · SKU EKO-UT136C+.