The TASI TA642B digital anemometer includes a USB connection. That can be valuable when planning to retain air-speed observations, but the presence of a port does not establish the software, file format, sampling interval or export workflow you need.
Before a site visit, run a short end-to-end rehearsal with the actual meter, computer and supported software. The aim is to prove that a reading can become a usable record, rather than discovering a missing step after the observation is finished.

Identify the B variant and the data requirement
The TA642B is the USB-equipped variant described here. The separate TA642A listing does not include USB. Similar controls and a shared family appearance are not enough to confirm an interface.
Write down the required output: an individual observation, a time sequence, a screenshot or a file another person can open. Then check the model's instructions for the supported route. Do not assume the REC key necessarily means autonomous time-stamped logging or that every USB cable carries data.
Rehearse the entire chain
Use the actual intended computer and the manufacturer's supported software route. Establish recognition of the device, confirm the active measurement and unit, then create a small test record using a benign airflow source within the instrument's instructions.
Save the result and open it again. Check that the values, units and time or sequence information are intelligible. If the available workflow provides only a live display or manual capture, document that limitation before committing to unattended logging.

Keep VEL, FLOW and temperature distinct
The TA642B lists wind-speed, flow and temperature readouts, with units including m/s, ft/min, ft/s, km/h, mph and knots. A retained number without its unit is incomplete.
Velocity and volume flow are also different quantities. Any volume-flow calculation needs the relevant area and method. A software column labelled flow does not remove those assumptions. Record the active function and the required area information if that function is used.
Check what happens when the session is interrupted
Learn the documented behaviour when the connection is lost, the meter powers down or the application closes. Does the record survive, stop or restart? Avoid assuming the software will recover a missing interval.
This is also a good time to confirm filenames and location labels. A file called “test1” may be enough for familiarisation, but it is poor handover material for several vents or observation positions. Include a route identifier and keep the measurement setup in accompanying notes.
Separate the digital record from the physical observation
A perfect file can still contain unrepresentative measurements if the vane position, orientation or operating conditions vary. Keep those conditions consistent and note any change. For outdoor work, a gust and a sustained observation are different descriptions; do not relabel an unspecified maximum as a standard meteorological gust.
Interest in digital anemometer accuracy should therefore include the method and the record, not just the display specification. USB is useful when it preserves enough context to support the intended comparison.
Leave with a checked result
Before ending the visit, confirm that the expected records exist and that a representative file can be read. Keep the source files as well as any summary prepared for a colleague.
That rehearsal gives the TA642B's USB connection a concrete purpose and makes the difference between “the meter connected” and “the observation is recoverable”.

See the TASI TA642B product page for the current version and kit, or read the TASI TA642B overview before choosing.