The TASI TA642A has wind-speed, temperature and flow readouts, but this A variant does not include USB. A useful observation record is still possible: prepare a clear manual sheet, keep units consistent and preserve the location and operating state attached to each value.
The aim is to make the observation recoverable without promising an interface the model does not have.
The three scene illustrations below were AI-generated using product reference images. They explain the workflow and are not records of our own inspections or measured results.

Pick the reporting unit before the session
The listed wind-speed units include m/s, ft/min, ft/s, km/h, mph and knots. Choose the unit appropriate to the task and keep it stable while recording. Changing units halfway through a sequence makes transcription errors more likely.
If a conversion is useful later, retain the original value as well. As an arithmetic example, 5 m/s equals 18 km/h and approximately 11.2 mph. The additional decimal places in a conversion do not improve the accuracy of the original observation.
Write the unit in the column heading and confirm it on the display before each group of measurements. A value of 10 without a unit is not a complete wind-speed record.
Define the observation position
For an outdoor comparison, record height, nearby obstructions, orientation and the observation period. For a vent check, identify the probe location, distance and system state. A value taken beside a wall or at a grille is not automatically representative of an open-field wind or a whole ventilation system.
Keep conditions as comparable as practical. The local reading can change because the wind changes, the position changes or the surrounding equipment changes. The note should make those possibilities visible.

Give HOLD and MAX/MIN a clear meaning
The TA642A has HOLD ZERO, REC and MAX MIN controls. Check the manual for their exact behaviour. A label on a key does not establish autonomous logging, a time-stamped file or a particular averaging interval.
If using HOLD to read the screen comfortably, record where and when the value was captured. If keeping a maximum, identify the observation period it belongs to. Do not call it a standard gust measurement unless the method matches that definition.
Keep flow calculations separate
VEL and FLOW are different functions. A volume-flow result depends on the relevant area and method, not only the vane's speed observation. Record the area and settings if using that function, and check the correct units.
For a manual report, it can be clearer to retain the original speed observations and document a separate calculation. That allows someone else to see which part was measured and which part was inferred.
Use a sheet that makes omissions obvious
Prepare fields for time, position, speed, unit, temperature, mode and operating condition. Add a notes column for interruptions or unstable observations. A blank cell is easier to spot than a missing detail in a paragraph written afterwards.
Photograph a representative screen where appropriate and safe, then compare it with the transcription. This helps catch unit mistakes without pretending a photograph is continuous logging.

Decide whether USB is actually required
If the job needs automatic computer transfer, investigate the separate TA642B and its supported workflow. Do not assume the A model can be upgraded by adding a cable. For short, clearly defined observations, a disciplined manual record may already answer the question.
The TA642A is most useful when its multi-unit display is paired with an equally clear record. Good labels and consistent positions are more valuable than an unexplained list of numbers.
See the TASI TA642A product page for the current version and kit, or read the TASI TA642A overview before choosing.