LC1020E: Compare a Component at Two Documented Test Frequencies

The LC1020E is described as a handheld LCR bridge with five test frequencies, three RMS test levels, open/short calibration and comparison functions. If a component behaves differently at two frequencies, the frequenc...

By EkoDeluxe · Published · Updated

LC1020E LCR Meter product view

The LC1020E is described as a handheld LCR bridge with five test frequencies, three RMS test levels, open/short calibration and comparison functions. If a component behaves differently at two frequencies, the frequency is the controlled variable. The result should preserve that context instead of collapsing it into one ‘true’ number.

LC1020E LCR Meter product view

LC1020E LCR Meter — supplier product view.

LC1020E LCR Meter used with component probes

Manufacturer application artwork; it illustrates probe placement and is not an EkoDeluxe test.

Choose the component and question

Reddit LCR discussions use ‘open and short compensations’ and point out that many LCR meters operate below RF, often around 100 kHz or less. Start with an isolated component and decide whether you are comparing frequency response, nominal value or pass/fail spread. Do not infer an RF result from a low-frequency bench check.

LC1020E LCR Meter shown in an application scene

Manufacturer application artwork; it illustrates a possible setup and is not an EkoDeluxe test.

Calibrate the fixture first

Use the supplied shorting plate, Kelvin clip or leads as the exact setup requires, then run the documented open and short compensation. The manufacturer material lists 100 Hz, 120 Hz, 1 kHz, 10 kHz and 100 kHz, plus 0.1, 0.3 and 0.6 V test levels. Record both frequency and test level beside the component value.

Workflow diagram for LC1020E LCR Meter

Original workflow diagram: the record keeps setup, observation and boundary together.

Compare two rows, not two memories

Measure the same component twice without changing contact placement, then change only the documented frequency. Save primary and secondary parameters, series/parallel model and any pass/fail setting. The LC1020E listing gives the broad role and the manufacturer page supplies the detailed control list; do not upgrade a marketing accuracy line when the detailed table is the more cautious source.

Explain the difference

A frequency-dependent reading may reflect the component, fixture, parasitics or the instrument’s model. The article’s contribution is a traceable comparison, not a universal component diagnosis.

Keep a record someone else can use

The LC1020E comparison sheet can have columns for frequency, RMS level, mode, primary value, secondary value, fixture and repeat number. Keep a reference part in the batch. Use the merchant page for the current purchase record and the manufacturer description for its detailed control list.

A practical handover

Write down the exact model, the setup, the observation and the limit that still needs checking. For current version and buying information, use the LC1020E LCR Meter product page.

For the related product overview, see the LC1020E LCR Meter Learn More page.