1Basket

FNIRSI · Guide

FNIRSI CTG-20: Zero and Multi-Point Calibration Before a Paint Survey

FNIRSI CTG-20 calibration begins with a suitable uncoated reference substrate and the manufacturer's procedure. Zero establishes the reference response; multi-point calibration addresses response at additional known t...

By EkoDeluxe · Published · Updated

FNIRSI CTG-20 product view

FNIRSI CTG-20 calibration begins with a suitable uncoated reference substrate and the manufacturer's procedure. Zero establishes the reference response; multi-point calibration addresses response at additional known thicknesses. Neither step should be replaced by adjusting the gauge on an unknown painted panel.

For a paint survey, verify the gauge over the part of the range you expect to use. A correct zero alone does not demonstrate that every later reading will be correct.

FNIRSI CTG-20 product view

FNIRSI CTG-20 supplier product photograph. Displayed values are illustrative.

Match the substrate to the measurement

The CTG-20 uses electromagnetic-induction and eddy-current sensing for supported coatings on steel/iron and non-magnetic metal substrates such as aluminium. Check the substrate indication and follow the relevant calibration procedure for that material.

Use reference plates and foils with known values and suitable condition. Keep them clean, flat and appropriate to the application. A contaminated plate or damaged foil can introduce an error before the vehicle inspection starts.

Do not assume that an adjustment made on one metal establishes performance on the other. If the inspection includes steel and aluminium, retain the required reference checks for both.

Separate calibration adjustment from verification. ZERO: Suitable clean reference substrate. MULTI-POINT: Known foils; exact model procedure. VERIFY: Repeat appropriate reference checks

A correct zero alone does not verify every thickness in the range

Distinguish adjustment from verification

Follow the exact sequence for zero and multi-point calibration in the CTG-20 instructions. Choose the prescribed reference thicknesses and confirm the required settings. The aim is to establish response against known references, not to make an unfamiliar sample agree with an expectation.

After adjustment, verify the result using appropriate reference checks. Lift and reseat the probe consistently and inspect repeatability. Record the reference values, substrate and any relevant conditions. If verification fails, resolve the cause before collecting a large set of panel readings.

Keep a separate check after the survey where the procedure requires it. That helps identify whether the instrument setup remained consistent during the work.

Resolution is not the complete error

This CTG-20 version lists a 0–1400 µm range, 0.1 µm resolution and an accuracy expression of ±(3% + 2) µm. Consult the full manual conditions and the definition of the percentage term for the required measurement.

A display step of 0.1 µm does not establish accuracy to 0.1 µm. Avoid reporting more certainty than the specification and setup justify. Reference uncertainty, surface condition, curvature and probe placement can all matter.

The model also offers µm and mil units. One mil is 25.4 µm. Set the unit before the survey and preserve it in the record, especially if reference foils and inspection notes use different conventions.

Carry the reference into the survey

Measure on clean, dry, suitable metal surfaces and use a repeatable pattern. A coating gauge generally measures the coating system over the substrate; calibration does not turn it into a layer-specific clear-coat instrument or a plastic-substrate gauge.

The listed unit uses a 600 mAh battery with USB-C charging. Confirm this exact version rather than borrowing a larger range from another CTG-20 description. Its useful role is a verified coating survey supported by reference checks, not a collection of precise-looking numbers with an unknown zero.

For the current specification and supplied version, see the FNIRSI CTG-20 product page.