The DPOS350P is listed with two channels, 350MHz bandwidth and a 1GSa/s sample rate. Those numbers belong together when you decide what a trace can tell you. A high bandwidth does not guarantee that every acquired record contains enough samples to show a waveform's fine detail.
Keep the actual acquisition settings with the screenshot, rather than leaving the headline specifications to explain it afterwards.

DPOS350P supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Count samples in the event of interest
At 1GSa/s, the nominal interval between samples is 1ns. A 10MHz repeating signal has a 100ns period, corresponding to 100 samples per cycle at that rate. A 350MHz period is about 2.86ns, corresponding to fewer than three samples. These are arithmetic examples using the headline rate, not measurements of the DPOS350P or claims about its processing.
The comparison explains why frequency detection and faithful shape inspection are different tasks. A complex edge or short glitch may need substantially more acquisition detail than the bare minimum for recognising a repeating frequency.
Record the rate actually used
Check the exact-model documentation for how sample rate, active channels, timebase, memory and acquisition mode interact. Do not assume the listed maximum applies simultaneously to every channel and every record length. Include the rate shown for the actual capture where the instrument provides it.
A longer time window may involve a different acquisition arrangement from a close view of a few cycles. If the purpose is to catch a rare event, consider both the observation duration and the detail retained within each event. A visually smooth trace may include interpolation; smoothness is not a sample-count measurement.

Arithmetic from the headline rate; actual acquisition conditions must be checked.
Make the screenshot explain itself
Keep channel identity, probe attenuation, voltage scale, timebase, trigger and relevant acquisition information visible or written beside the image. Add the source or circuit state and the event you were looking for. A cropped trace without its axes is difficult to assess.
Use suitable probes and an approved reference arrangement for the intended circuit. The published product description does not provide a complete input-protection, isolation or probe specification. A tablet format does not establish safe floating measurements.
When comparing oscilloscope price, compare the complete acquisition job: event duration, bandwidth, channel count, sampling conditions and accessories. The DPOS350P's headline numbers may help shortlist it, but the saved capture needs to show the conditions that produced it. That is what allows another person to decide whether the trace answers your question.
For the current specification and supplied version, see the DPOS350P product page.
For the related product overview, see the DPOS350P Oscilloscope Learn More page.