1Panier

BENETECH · Guide

BENETECH GM520 : la plage de mesure n’est pas la pression de service maximale

La plage de mesure différentielle du BENETECH GM520 est annoncée à ±10 kPa. La pression de service maximale indiquée séparément est de 50 kPa. Ces chiffres répondent à des questions différentes : l’un décrit l’étendue...

Par EkoDeluxe · Publié le · Mis à jour le

BENETECH GM520 product view

The BENETECH GM520 differential-pressure measuring range is listed as ±10 kPa. Its separately listed maximum working pressure is 50 kPa. These figures answer different questions: one describes the measuring span; the other must not be treated as an extended accurate range.

Before connecting hoses, establish the expected pressure, the limits that apply to each connection and the suitability of the medium. Do not use the 50 kPa headline as a target to approach during a measurement.

BENETECH GM520 product view

BENETECH GM520 supplier product photograph. Displayed values are illustrative.

Draw the pressure connections first

For a ventilation comparison, identify the two points whose pressure difference you want to observe. Label which point connects to the positive port and which connects to the negative port. Follow the instrument and system instructions for taking pressure at those locations.

A manometer measures pressure difference at its ports. It does not automatically distinguish static pressure from the effect of a poorly positioned sampling tube in moving air. Probe type, orientation and tapping location belong in the method.

Check hoses for damage, obstruction and trapped liquid. Confirm their compatibility and the pressure limits of the complete arrangement. The reviewed GM520 description does not establish universal liquid or chemical compatibility.

GM520: measuring span and pressure limit differ. ±10 kPa: Listed differential measuring range. 50 kPa: Separately listed maximum working pressure. CHECK: Permitted port pressures and medium

50 kPa is not an extension of the accurate measuring range

Zero under the correct condition

Follow the model's zeroing instructions with the ports in the required equal-pressure condition. Do not zero away a real system difference and then call the new value an absolute system result. Record when zero was established and what the hoses were connected to at that time.

After connection, allow the display to settle. If the reading has the opposite sign from your expectation, check the port assignment before concluding that the system has reversed flow. Pressure sign describes the chosen comparison, not a fault code.

Keep pressure and airflow separate

Airflow and static pressure are related through the system, but they are different quantities. A pressure difference alone does not give CFM or cubic metres per hour. Converting it into flow requires a suitable method, such as a valid device-specific pressure/flow relationship and the correct measurement locations.

For a filter investigation, repeat the pressure check at the same fan state and tapping points. A different fan speed can change the result even if the filter has not changed. Retain the operating conditions beside the number.

Make the USB record interpretable

The GM520 lists dual ports, HOLD, DIF, REC and a USB data connection. Confirm the software, recording behaviour and export compatibility before a session that depends on them. A REC label is not enough to infer an unattended recording duration.

Keep the original file with a connection sketch, units, zero condition and event notes. Recheck zero afterwards as directed, particularly if a small difference will drive the decision.

Use the GM520 for a verified pressure task within its measuring and operating limits. Gas-appliance adjustment requires the appropriate competence, procedures and equipment; a generic ventilation example is not a commissioning method for a boiler.

For the current specification and supplied version, see the BENETECH GM520 product page.

Autres guides