{"product_id":"uni-t-ut521-digital-earth-tester","title":"UNI-T UT521 Digital Earth Tester","description":"\u003cp\u003eThe UNI-T UT521 is a digital earth tester with 20 Ω, 200 Ω and 2000 Ω resistance ranges and a separate earth-voltage mode. It uses V\/E\/P\/C terminals and provides HOLD, SAVE and display-light controls. Follow the supplied manual for the required test arrangement.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT521\u003c\/strong\u003e is a handheld \u003cstrong\u003edigital earth tester\u003c\/strong\u003e for earth-resistance and earth-voltage checks on suitable installations — not an RCD (ELCB) tester and not an insulation multimeter. Face silk: \u003cem\u003eUNI-T DIGITAL EARTH TESTER UT521\u003c\/em\u003e. English UI on this capture: \u003cstrong\u003e000.0 \/ V~\u003c\/strong\u003e. Keys: \u003cstrong\u003eLIGHT\/LOAD\u003c\/strong\u003e · \u003cstrong\u003eHOLD\/SAVE\u003c\/strong\u003e · \u003cstrong\u003eTEST\u003c\/strong\u003e. Dial: \u003cstrong\u003eOFF · 2000Ω · 200Ω · 20Ω · EARTH VOLTAGE · OFF\u003c\/strong\u003e. Terminals: \u003cstrong\u003eV\u003c\/strong\u003e (MAX \u003cstrong\u003e200V\u003c\/strong\u003e · silk \u003cstrong\u003eCAT III 600V\u003c\/strong\u003e) · \u003cstrong\u003eE\u003c\/strong\u003e · \u003cstrong\u003eP\u003c\/strong\u003e · \u003cstrong\u003eC\u003c\/strong\u003e. Supplier attributes list measuring range \u003cstrong\u003e0–2000Ω\u003c\/strong\u003e, testing voltage \u003cstrong\u003e0–200V\u003c\/strong\u003e, body about \u003cstrong\u003e160 × 100 × 70.5 mm\u003c\/strong\u003e, mass \u003cstrong\u003e560 g\u003c\/strong\u003e, power \u003cstrong\u003e6 × 1.5V AA (LR6)\u003c\/strong\u003e, and listed accuracy class \u003cstrong\u003e±(2%+3)\u003c\/strong\u003e — confirm accuracy and kit contents in the supplied manual and on this buying page. UK price \u003cstrong\u003e\u003c\/strong\u003e, free delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UNI-T UT522 (same-batch pending listing elsewhere), and \u003cstrong\u003enot\u003c\/strong\u003e UT512 or UT513A. This page is the \u003cstrong\u003eUT521 digital earth tester\u003c\/strong\u003e only — English UI \u003cstrong\u003e000.0 \/ V~\u003c\/strong\u003e, ohm ranges \u003cstrong\u003e20 \/ 200 \/ 2000Ω\u003c\/strong\u003e, \u003cstrong\u003eEARTH VOLTAGE\u003c\/strong\u003e path, terminals \u003cstrong\u003eV \/ E \/ P \/ C\u003c\/strong\u003e with \u003cstrong\u003eMAX 200V\u003c\/strong\u003e and silk \u003cstrong\u003eCAT III 600V\u003c\/strong\u003e at V. Do not use 522\/512\/513A co-branded images or another model’s photo for ranges or accessories. Stake spacing, 2-pole \/ 3-pole method numbers and soil-resistivity formulas are not invented here — follow the method you are working to and the supplied manual.\u003c\/p\u003e\n\n\u003ch2\u003eDigital earth tester: pick the ohm range, then TEST\u003c\/h2\u003e\n\u003cp\u003eThe UT521 is built for earth-resistance readings on the \u003cstrong\u003e20Ω · 200Ω · 2000Ω\u003c\/strong\u003e dial positions and for an \u003cstrong\u003eEARTH VOLTAGE\u003c\/strong\u003e path on the same handheld. Connect leads to \u003cstrong\u003eE \/ P \/ C\u003c\/strong\u003e (and \u003cstrong\u003eV\u003c\/strong\u003e when the voltage path requires it) as the manual diagrams, pick the ohm range that matches the expected reading, then press \u003cstrong\u003eTEST\u003c\/strong\u003e. Use \u003cstrong\u003eHOLD\/SAVE\u003c\/strong\u003e to keep a value and \u003cstrong\u003eLIGHT\/LOAD\u003c\/strong\u003e as the manual describes for backlight \/ load. This page does not invent stake spacing, pole-method step counts or soil-resistivity equations — follow the method you are working to and the supplied manual. Confirm kit contents on this buying page before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Digital earth tester — earth resistance \/ earth voltage\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T DIGITAL EARTH TESTER UT521\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: 000.0 \/ V~\u003c\/li\u003e\n\u003cli\u003eKeys: LIGHT\/LOAD · HOLD\/SAVE · TEST\u003c\/li\u003e\n\u003cli\u003eDial: OFF · 2000Ω · 200Ω · 20Ω · EARTH VOLTAGE · OFF\u003c\/li\u003e\n\u003cli\u003eTerminals: V (MAX 200V · CAT III 600V) · E · P · C\u003c\/li\u003e\n\u003cli\u003eMeasuring range (supplier attribute): 0–2000Ω\u003c\/li\u003e\n\u003cli\u003eTesting voltage (supplier attribute): 0–200V\u003c\/li\u003e\n\u003cli\u003eListed accuracy class (supplier attribute): ±(2%+3) — confirm in the supplied manual\u003c\/li\u003e\n\u003cli\u003eBody (supplier attribute): about 160 × 100 × 70.5 mm\u003c\/li\u003e\n\u003cli\u003eMass (supplier attribute): 560 g\u003c\/li\u003e\n\u003cli\u003ePower: 6 × 1.5V AA (LR6)\u003c\/li\u003e\n\u003cli\u003eStake spacing \/ 2-pole \/ 3-pole method numbers \/ soil resistivity formulas: follow the method and supplied manual — not invented here\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to take a useful reading\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the earth electrode \/ circuit under test is safe to approach and that the method you are following allows an earth-resistance or earth-voltage check at this point. Observe the warnings in the supplied manual.\u003c\/li\u003e\n\u003cli\u003eConnect leads to \u003cstrong\u003eE\u003c\/strong\u003e, \u003cstrong\u003eP\u003c\/strong\u003e and \u003cstrong\u003eC\u003c\/strong\u003e as the manual diagrams for the earth-resistance run. Use terminal \u003cstrong\u003eV\u003c\/strong\u003e when the method requires the earth-voltage path (respect \u003cstrong\u003eMAX 200V\u003c\/strong\u003e and silk \u003cstrong\u003eCAT III 600V\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eTurn the dial to \u003cstrong\u003e20Ω\u003c\/strong\u003e, \u003cstrong\u003e200Ω\u003c\/strong\u003e or \u003cstrong\u003e2000Ω\u003c\/strong\u003e so the range matches the expected reading — or select \u003cstrong\u003eEARTH VOLTAGE\u003c\/strong\u003e for the voltage path. Do not invent stake spacing or pole-method numbers on this page.\u003c\/li\u003e\n\u003cli\u003ePress \u003cstrong\u003eTEST\u003c\/strong\u003e and read the English UI (\u003cstrong\u003e000.0\u003c\/strong\u003e class display; \u003cstrong\u003eV~\u003c\/strong\u003e when on the voltage path). Use \u003cstrong\u003eHOLD\/SAVE\u003c\/strong\u003e to keep a value when you need to leave the point.\u003c\/li\u003e\n\u003cli\u003eRecord range (or EARTH VOLTAGE), terminal arrangement, point identity and the reading with the method reference. This page does not declare a legal pass\/fail for the installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut521-pick-the-ohm-range-before-you-press-test\"\u003eUNI-T UT521: Pick the Ohm Range Before You Press TEST\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT521\u003c\/li\u003e\n\u003cli\u003eType: Digital earth tester\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T DIGITAL EARTH TESTER UT521\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: 000.0 \/ V~\u003c\/li\u003e\n\u003cli\u003eKeys: LIGHT\/LOAD · HOLD\/SAVE · TEST\u003c\/li\u003e\n\u003cli\u003eDial: OFF · 2000Ω · 200Ω · 20Ω · EARTH VOLTAGE · OFF\u003c\/li\u003e\n\u003cli\u003eTerminals: V (MAX 200V · CAT III 600V) · E · P · C\u003c\/li\u003e\n\u003cli\u003eMeasuring range (supplier attribute): 0–2000Ω\u003c\/li\u003e\n\u003cli\u003eTesting voltage (supplier attribute): 0–200V\u003c\/li\u003e\n\u003cli\u003eListed accuracy class (supplier attribute): ±(2%+3) — confirm in the supplied manual\u003c\/li\u003e\n\u003cli\u003eBody size (supplier attribute): about 160 × 100 × 70.5 mm\u003c\/li\u003e\n\u003cli\u003eMass (supplier attribute): 560 g\u003c\/li\u003e\n\u003cli\u003ePower: 6 × 1.5V AA (LR6)\u003c\/li\u003e\n\u003cli\u003eStake spacing \/ 2-pole \/ 3-pole method numbers \/ soil-resistivity formulas: follow the method you are working to and the supplied manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, stakes, case, manual, batteries and any kit shown on this buying page before ordering. Follow the supplied manual for connection diagrams, operating limits and safety warnings. Do not treat this page as UT522, UT512 or UT513A. Accuracy detail beyond the listed class ±(2%+3), stake layouts and pole-method schedules are not invented here — use the manual and the method you are following.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT521\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eDigital earth-tester layout, pick the ohm range before TEST, EARTH VOLTAGE vs Ω paths, terminals V\/E\/P\/C, and how it differs from UT522 \/ UT512 \/ UT513A. \u003ca href=\"\/pages\/learn-uni-t-ut521\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut521-pick-the-ohm-range-before-you-press-test\"\u003eUNI-T UT521: Pick the Ohm Range Before You Press TEST\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What ohm ranges does the UNI-T UT521 offer?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The dial includes 20Ω, 200Ω and 2000Ω earth-resistance positions (plus OFF and EARTH VOLTAGE). Supplier attributes list measuring range 0–2000Ω. Pick the range that matches the expected reading before you press TEST — do not invent stake spacing or pole-method numbers on this page.\"}},{\"@type\":\"Question\",\"name\":\"What is EARTH VOLTAGE versus the Ω ranges on the UNI-T UT521?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"EARTH VOLTAGE is a separate dial path for earth-voltage checks on the English UI (V~ on this capture). The 20 \/ 200 \/ 2000Ω positions are for earth-resistance runs. Use terminal V as the manual diagrams when the voltage path requires it, and respect MAX 200V.\"}},{\"@type\":\"Question\",\"name\":\"What are terminals V, E, P and C for on the UNI-T UT521?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Silk marks V (MAX 200V · CAT III 600V), E, P and C. Connect E \/ P \/ C for earth-resistance arrangements as the manual shows; use V when the earth-voltage path requires it. Exact lead colours and stake layouts stay in the manual — not invented here.\"}},{\"@type\":\"Question\",\"name\":\"What does MAX 200V on terminal V mean on the UNI-T UT521?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Terminal V is silk-marked MAX 200V. Do not apply a higher voltage to that jack. Supplier attributes also list testing voltage 0–200V. Follow the supplied manual for safe connection and operating limits.\"}},{\"@type\":\"Question\",\"name\":\"What does CAT III 600V on the UNI-T UT521 mean?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Readable silk at terminal V includes CAT III 600V. Treat that as the category marking on this capture and still follow all markings on the unit and the supplied manual for the installation class you are working in. This page does not invent a higher category or a whole-system rating.\"}},{\"@type\":\"Question\",\"name\":\"How is the UNI-T UT521 different from UT522 and from UT512 \/ UT513A?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"UT521  is this digital earth tester page only. UT522 is same-batch pending elsewhere — not this listing. UT512 \/ UT513A are different models and must not share photos or copy. Confirm face silk DIGITAL EARTH TESTER UT521 and English UI 000.0 \/ V~ before you buy.\"}},{\"@type\":\"Question\",\"name\":\"What batteries does the UNI-T UT521 take, and how much does it weigh?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Power is 6 × 1.5V AA (LR6). Mass is 560 g (supplier net-weight attribute). Confirm batteries and the rest of the kit on the buying page.\"}},{\"@type\":\"Question\",\"name\":\"Is UK delivery free for the UNI-T UT521?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. \"}}]}\u003c\/script\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849952882747,"sku":"EKO-UT521","price":366.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT521_clean_en_1.jpg?v=1793691277","url":"https:\/\/ekodeluxe.co.uk\/products\/uni-t-ut521-digital-earth-tester","provider":"EkoDeluxe","version":"1.0","type":"link"}