{"product_id":"uni-t-ut278a-ground-tester","title":"UNI-T UT278A Clamp-On Ground Resistance Tester","description":"\u003cp\u003eThe UNI-T UT278A is a clamp-on ground tester for earth-resistance and leakage-current checks on suitable loops. This listing is the UT278A without a plus suffix, with HOLD, SAVE, alarm and memory controls. Its supplier-listed jaw opening is 32 mm.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT278A\u003c\/strong\u003e is a handheld \u003cstrong\u003eGROUND TESTER\u003c\/strong\u003e for \u003cstrong\u003eclamp-on\u003c\/strong\u003e earth-resistance and leakage-current checks on suitable loops — not a stake-style digital earth tester (≠ UT521 \/ UT522), not an Earth-ρ Tester (≠ UT523A), and not a multi-model 278A+ \/ 278B \/ 278C \/ 278D \/ 276A \/ 275 \/ 275A \/ 272A poster. Face silk: \u003cem\u003eUNI-T UT278A GROUND TESTER\u003c\/em\u003e (\u003cstrong\u003eno +\u003c\/strong\u003e). English UI on this capture: main \u003cstrong\u003e0.00 AC mA\u003c\/strong\u003e · sub-display \u003cstrong\u003e03\u003c\/strong\u003e · screen mark \u003cstrong\u003eHOLD\u003c\/strong\u003e (raw_1 \/ raw_2). Keys: large round \u003cstrong\u003eHOLD\u003c\/strong\u003e · power icon · \u003cstrong\u003eSAVE\u003c\/strong\u003e · \u003cstrong\u003eAL\u003c\/strong\u003e · \u003cstrong\u003eA\u003c\/strong\u003e \/ arrow · \u003cstrong\u003eMEM\u003c\/strong\u003e \/ square icon. Body: \u003cstrong\u003eCE\u003c\/strong\u003e. Jaw trigger opens\/closes the clamp. Supplier attributes (not face silk): measuring range \u003cstrong\u003e0.01–1200 Ω\u003c\/strong\u003e, leakage current through \u003cstrong\u003e30 A\u003c\/strong\u003e, jaw opening \u003cstrong\u003e32 mm\u003c\/strong\u003e, RS-232, data storage \u003cstrong\u003e99\u003c\/strong\u003e, visual \/ audible alarm, auto range. Kit capture (raw_6) may show case · 4×AA · RS-232 cable · 1 Ω \/ 10 Ω \/ 100 Ω verification rings — \u003cstrong\u003econfirm kit contents on this buying page\u003c\/strong\u003e and in the supplied manual. The included manual cover may read \u003cem\u003eUT276A\/278A\u003c\/em\u003e (shared OEM cover for the pair) — that is \u003cstrong\u003enot\u003c\/strong\u003e a second buyable model on this SKU; face silk \u003cstrong\u003eUT278A\u003c\/strong\u003e rules. Estimated freight weight about \u003cstrong\u003e1.40 kg\u003c\/strong\u003e (weight_est=Y) — \u003cstrong\u003econfirm weight on this buying page\u003c\/strong\u003e. UK price \u003cstrong\u003e\u003c\/strong\u003e, free delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e a plus-suffix listing sold as UT278A+ on other channels, \u003cstrong\u003enot\u003c\/strong\u003e UT278B \/ C \/ D, \u003cstrong\u003enot\u003c\/strong\u003e UT276A (shared manual cover is not a second model here), \u003cstrong\u003enot\u003c\/strong\u003e UT275 ( — EARTH CLAMP TESTER · 100 Ω \/ 01 · CAT III 300V), \u003cstrong\u003enot\u003c\/strong\u003e UT275A ( — Earth Clamp Meter · 10.0 Ω · MAX 30A~ · CAT IV 600V), \u003cstrong\u003enot\u003c\/strong\u003e UT272A , \u003cstrong\u003enot\u003c\/strong\u003e a stake-driven digital earth tester (UT521  \/ UT522), and \u003cstrong\u003enot\u003c\/strong\u003e an Earth-ρ Tester (UT523A). This page is the bare \u003cstrong\u003eUT278A GROUND TESTER\u003c\/strong\u003e only — English UI \u003cstrong\u003e0.00 AC mA \/ 03 \/ HOLD\u003c\/strong\u003e, keys HOLD · SAVE · AL · A · MEM, jaw opening \u003cstrong\u003e32 mm\u003c\/strong\u003e (supplier). Do not use 278A+ \/ 278B\/C\/D \/ 276A \/ 275 \/ 275A \/ 272A co-branded images or another model’s photo for ranges or accessories. Loop-test step counts and pass\/fail limits are not invented here — follow the method you are working to and the supplied manual. Respect supplier jaw opening \u003cstrong\u003e32 mm\u003c\/strong\u003e and leakage path through \u003cstrong\u003e30 A\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eGround Tester: confirm bare UT278A silk — not a plus-suffix listing\u003c\/h2\u003e\n\u003cp\u003eThe UT278A is built for \u003cstrong\u003eclamp-on\u003c\/strong\u003e earth-resistance and leakage-current readings: power on, close the jaw around a suitable earth conductor \/ loop, read the English UI (resistance path or leakage \/ AC mA path as the supplied manual describes), then use large \u003cstrong\u003eHOLD\u003c\/strong\u003e, \u003cstrong\u003eSAVE\u003c\/strong\u003e, \u003cstrong\u003eAL\u003c\/strong\u003e, \u003cstrong\u003eA\u003c\/strong\u003e and \u003cstrong\u003eMEM\u003c\/strong\u003e as the manual describes. That is a different instrument class from UT521 \/ UT522 stake-style digital earth testers and from UT523A’s ρEARTH \/ REARTH \/ EARTH VOLTAGE dial — and a different listing from recently published \u003cstrong\u003eUT275\u003c\/strong\u003e ( EARTH CLAMP TESTER), \u003cstrong\u003eUT275A\u003c\/strong\u003e ( Earth Clamp Meter) and \u003cstrong\u003eUT272A\u003c\/strong\u003e , and from near models UT278B \/ C \/ D and UT276A. Confirm the face silk \u003cem\u003eUT278A GROUND TESTER\u003c\/em\u003e (\u003cstrong\u003eno +\u003c\/strong\u003e), the English UI \u003cstrong\u003e0.00 AC mA \/ 03 \/ HOLD\u003c\/strong\u003e, and supplier jaw opening \u003cstrong\u003e32 mm\u003c\/strong\u003e before you compare prices or procedures. A shared manual cover marked UT276A\/278A does \u003cstrong\u003enot\u003c\/strong\u003e make UT276A the sellable model on this page. This page does not invent loop-test step counts or legal pass\/fail limits — follow the method you are working to and the supplied manual. Confirm kit contents on this buying page before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: GROUND TESTER — clamp-on earth resistance + leakage current (paths per manual)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT278A GROUND TESTER (no +)\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: 0.00 AC mA · sub-display 03 · screen HOLD (raw_1\/2)\u003c\/li\u003e\n\u003cli\u003eKeys: large HOLD · power icon · SAVE · AL · A \/ arrow · MEM \/ square\u003c\/li\u003e\n\u003cli\u003eBody marking: CE\u003c\/li\u003e\n\u003cli\u003eJaw opening (supplier attribute): 32 mm\u003c\/li\u003e\n\u003cli\u003eResistance (supplier attribute): 0.01–1200 Ω\u003c\/li\u003e\n\u003cli\u003eLeakage current (supplier attribute): through 30 A\u003c\/li\u003e\n\u003cli\u003eInterface \/ memory (supplier attribute): RS-232 · data storage 99 · visual \/ audible alarm · auto range\u003c\/li\u003e\n\u003cli\u003eKit (raw_6 support): case · 4×AA · RS-232 · 1 Ω \/ 10 Ω \/ 100 Ω rings — confirm on this buying page\u003c\/li\u003e\n\u003cli\u003eManual cover: may show UT276A\/278A shared OEM cover — face silk UT278A rules; do not sell as UT276A\u003c\/li\u003e\n\u003cli\u003eWeight: freight estimate about 1.40 kg (weight_est=Y) — confirm weight on this buying page\u003c\/li\u003e\n\u003cli\u003eLoop-check steps \/ pass-fail limits: follow the method and supplied manual — not invented here\u003c\/li\u003e\n\u003cli\u003eStrong contrast to plus-suffix \/ near models: bare UT278A only — do not share photos or copy with UT278A+ \/ UT278B\/C\/D \/ UT276A \/ UT275 \/ UT275A \/ UT272A\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to take a useful reading\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the earth conductor \/ loop under test is safe to approach and that the method you are following allows a clamp-on earth-resistance or leakage-current check at this point. Observe the warnings in the supplied manual and all markings on the unit.\u003c\/li\u003e\n\u003cli\u003ePower on with the power icon. Select the resistance or leakage \/ AC mA path as the supplied manual describes — before you treat a number as meaningful. Do not invent loop-test step counts or pass\/fail limits on this page. Do not borrow UT275 POWER \/ MODE layouts, UT275A combined Ω\/A · READ expectations, UT521 \/ UT522 stake-method expectations, or UT523A ρEARTH \/ REARTH dial paths as if they were this meter.\u003c\/li\u003e\n\u003cli\u003eOpen the jaw with the trigger, seat the clamp fully around the conductor \/ loop within the supplier jaw opening \u003cstrong\u003e32 mm\u003c\/strong\u003e, and close the jaw so the reading path is complete.\u003c\/li\u003e\n\u003cli\u003eRead the English UI (\u003cstrong\u003e0.00 AC mA\u003c\/strong\u003e class · sub-display \u003cstrong\u003e03\u003c\/strong\u003e · screen \u003cstrong\u003eHOLD\u003c\/strong\u003e on this capture when HOLD is active). Use large \u003cstrong\u003eHOLD\u003c\/strong\u003e, \u003cstrong\u003eSAVE\u003c\/strong\u003e, \u003cstrong\u003eAL\u003c\/strong\u003e, \u003cstrong\u003eA\u003c\/strong\u003e and \u003cstrong\u003eMEM\u003c\/strong\u003e as the manual describes when you need to hold, store, alarm or navigate memory.\u003c\/li\u003e\n\u003cli\u003eRecord path context, clamp-point identity and the reading with the method reference. This page does not declare a legal pass\/fail for the installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut278a-confirm-bare-ut278a-not-plus\"\u003eUNI-T UT278A: Confirm Bare UT278A — Not UT278A+\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT278A (bare — no +)\u003c\/li\u003e\n\u003cli\u003eType: GROUND TESTER (clamp-on earth resistance + leakage current)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT278A GROUND TESTER\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: 0.00 AC mA · sub-display 03 · screen HOLD\u003c\/li\u003e\n\u003cli\u003eKeys: large HOLD · power icon · SAVE · AL · A \/ arrow · MEM \/ square\u003c\/li\u003e\n\u003cli\u003eBody marking: CE\u003c\/li\u003e\n\u003cli\u003eJaw opening (supplier attribute): 32 mm\u003c\/li\u003e\n\u003cli\u003eResistance (supplier attribute): 0.01–1200 Ω\u003c\/li\u003e\n\u003cli\u003eLeakage current (supplier attribute): through 30 A\u003c\/li\u003e\n\u003cli\u003eRS-232 · data storage 99 · visual \/ audible alarm · auto range (supplier attributes)\u003c\/li\u003e\n\u003cli\u003eKit \/ batteries: confirm on this buying page (raw_6 support may show case · 4×AA · RS-232 · verification rings)\u003c\/li\u003e\n\u003cli\u003eWeight: confirm on this buying page (freight estimate about 1.40 kg; weight_est=Y)\u003c\/li\u003e\n\u003cli\u003eManual: shared UT276A\/278A cover possible — face silk UT278A rules\u003c\/li\u003e\n\u003cli\u003eLoop-check steps \/ pass-fail limits: follow the method you are working to and the supplied manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm batteries, case and any kit shown on this buying page before ordering. Follow the supplied manual for operating limits and safety warnings. Do not treat this page as a plus-suffix listing, UT278B \/ C \/ D, UT276A, UT275, UT275A, UT272A, UT521, UT522 or UT523A. Loop-test schedules are not invented here — use the manual and the method you are following.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\u003cp\u003eGet to know the UNI-T UT278A — GROUND TESTER layout, bare UT278A silk (not a plus-suffix listing), English UI 0.00 AC mA \/ HOLD, HOLD · SAVE · AL · A · MEM, jaw opening 32 mm (supplier), and how it differs from UT275 \/ UT275A \/ UT272A \/ UT278B–D \/ UT276A \/ UT521 \/ UT522 \/ UT523A. \u003ca href=\"\/pages\/learn-uni-t-ut278a\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the UNI-T UT278A measure?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It is a clamp-on GROUND TESTER for earth-resistance and leakage-current checks on suitable loops. Paths follow the supplied manual. That is a different instrument class from stake-style UT521 \/ UT522 digital earth testers and from UT523A’s Earth-ρ dial — and a different listing from UT275 \/ UT275A \/ UT272A and from plus-suffix \/ near-letter models.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is the UNI-T UT278A the same as a plus-suffix UT278A listing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. This page is bare UT278A only — face silk UT278A GROUND TESTER with no +. Plus-suffix listings on other channels are a different product identity and must not share photos, ranges or procedures with this SKU.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is the UNI-T UT278A different from UT275 \/ UT275A \/ UT272A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"UT278A  silk reads GROUND TESTER, English UI 0.00 AC mA \/ 03 \/ HOLD, keys HOLD · SAVE · AL · A · MEM, jaw opening 32 mm (supplier). UT275  is an EARTH CLAMP TESTER with 100 Ω \/ 01 and body CAT III 300V. UT275A  is an Earth Clamp Meter with 10.0 Ω and jaw silk MAX 30A~ · CAT IV 600V. UT272A  is a different Earth Clamp Meter listing. Do not share photos, ranges or procedures.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is the UNI-T UT278A different from UT278B \/ C \/ D \/ UT276A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Bare UT278A is this GROUND TESTER page only. UT278B \/ C \/ D and UT276A are different models. A shared manual cover marked UT276A\/278A does not make UT276A the sellable model here — face silk UT278A rules.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is the UNI-T UT278A different from UT521 \/ UT522 \/ UT523A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"UT278A clamps the conductor \/ loop. UT521  and UT522  are stake-style digital earth testers. UT523A  is an Earth-ρ Tester. Do not share photos, ranges or procedures across these models.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What do the HOLD, SAVE and AL keys do on the UNI-T UT278A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Large HOLD freezes a value as the manual describes (screen can show HOLD). SAVE stores a reading; AL is the alarm key — use both as the supplied manual describes. A and MEM navigate \/ recall as the manual describes. This page does not invent memory-capacity marketing beyond the supplier attribute data storage 99.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What jaw opening and ranges apply on the UNI-T UT278A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Supplier attributes list jaw opening 32 mm, resistance 0.01–1200 Ω, and leakage current through 30 A. Loop-check step counts and legal pass\/fail limits stay with the method you are working to and the supplied manual — not with this page.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the shared UT276A\/278A manual mean I am buying UT276A with the UNI-T UT278A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. The OEM manual cover may be shared for the pair; the buyable model on this page is bare UT278A per face silk. Do not treat UT276A as a second model or co-list it here.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How much does the UNI-T UT278A weigh, and what is in the kit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Freight estimate about 1.40 kg (weight_est=Y) — confirm weight on this buying page. Kit support capture may show case · 4×AA · RS-232 · verification rings — confirm full kit on this buying page and in the supplied manual.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is UK delivery free for the UNI-T UT278A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. \"\n      }\n    }\n  ]\n}\u003c\/script\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8087202037819-ground-test-setup\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: set up a repeatable ground observation\u003c\/h2\u003e\n\u003cp\u003eUse the exact tester with a visible training earth point or isolated test lead, keeping clamps and probes on the intended conductor. Show the test position and record sheet without a readable resistance value or a claim about the whole installation.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-productssunburst50-p8087202037819-ground-test-setup-v1.webp?v=1794924780\" alt=\"UNI-T UT278A Clamp-On Ground Resistance Tester ground tester positioned at an isolated earth test point\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: UNI-T UT278A Clamp-On Ground Resistance Tester ground tester positioned at an isolated earth test point. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44850602672187,"sku":"EKO-UT278A","price":821.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT278A_clean_en_1.jpg?v=1793697928","url":"https:\/\/ekodeluxe.co.uk\/products\/uni-t-ut278a-ground-tester","provider":"EkoDeluxe","version":"1.0","type":"link"}