{"product_id":"uni-t-ut272a-earth-clamp-meter","title":"UNI-T UT272A Earth Clamp Meter","description":"\u003cp\u003eThe UNI-T UT272A is an earth clamp meter for ground-resistance checks on suitable loops. It has separate Ω and A controls, HOLD, READ and SAVE functions and uses four AA batteries. Check the supplied manual for loop requirements and the applicable measurement method.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT272A\u003c\/strong\u003e is a handheld \u003cstrong\u003eEarth Clamp Meter\u003c\/strong\u003e for \u003cstrong\u003eclamp-on\u003c\/strong\u003e ground-resistance checks on suitable loops — not a stake-style digital earth tester (≠ UT521 \/ UT522), not an Earth-ρ Tester (≠ UT523A), and not a multi-model 272+ \/ 275 \/ 278 poster. Face silk: \u003cem\u003eUNI-T UT272A Earth Clamp Meter\u003c\/em\u003e. English UI on this capture: \u003cstrong\u003e10.0 Ω\u003c\/strong\u003e (raw_1 \/ raw_2) and \u003cstrong\u003e1.00 Ω\u003c\/strong\u003e (raw_4). Keys: yellow\/orange power · blue \u003cstrong\u003eHOLD\u003c\/strong\u003e (with backlight icon) · \u003cstrong\u003eΩ\u003c\/strong\u003e · \u003cstrong\u003eA\u003c\/strong\u003e · \u003cstrong\u003eOK\u003c\/strong\u003e · \u003cstrong\u003eREAD\u003c\/strong\u003e · ↑ \/ ↓ (silk \u003cstrong\u003eCLEAR\u003c\/strong\u003e beside) · \u003cstrong\u003eSAVE\u003c\/strong\u003e; face print \u003cstrong\u003eAPO\u003c\/strong\u003e. Jaw trigger opens\/closes the clamp; jaw-side silk readable on priority captures: \u003cstrong\u003eCAT IV 300V\u003c\/strong\u003e. Back (raw_3): battery door \u003cstrong\u003eAA 1.5V ×4\u003c\/strong\u003e, CE \/ ETL marks, no model text — usable as a support image. Supplier attributes (not face silk): measuring range \u003cstrong\u003e0 Ω ~ 2000 Ω\u003c\/strong\u003e, current range \u003cstrong\u003e0 A ~ 1 A\u003c\/strong\u003e, testing voltage \u003cstrong\u003e5 V\u003c\/strong\u003e, insulation resistance \u003cstrong\u003e\u0026gt; 1 MΩ\u003c\/strong\u003e. Accuracy class on the source page is treated as uncertain — not used as a selling claim here. Confirm kit contents and weight on this buying page and in the supplied manual. UK price \u003cstrong\u003e\u003c\/strong\u003e, free delivery.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e a stake-driven digital earth tester (UT521  \/ UT522), \u003cstrong\u003enot\u003c\/strong\u003e an Earth-ρ Tester (UT523A), \u003cstrong\u003enot\u003c\/strong\u003e UT272+, \u003cstrong\u003enot\u003c\/strong\u003e UT275 \/ UT275A, \u003cstrong\u003enot\u003c\/strong\u003e UT278A \/ B, and \u003cstrong\u003enot\u003c\/strong\u003e UT270+ \/ UT273+. This page is the \u003cstrong\u003eUT272A Earth Clamp Meter\u003c\/strong\u003e only — English UI \u003cstrong\u003e10.0 Ω \/ 1.00 Ω\u003c\/strong\u003e, main path \u003cstrong\u003eΩ\u003c\/strong\u003e (optional \u003cstrong\u003eA\u003c\/strong\u003e leakage-current path per the manual), jaw silk \u003cstrong\u003eCAT IV 300V\u003c\/strong\u003e, face print \u003cstrong\u003eAPO\u003c\/strong\u003e. Do not use 272+ \/ 275* \/ 278* \/ 270+ \/ 273+ co-branded images or another model’s photo for ranges or accessories. Clamp jaw opening size, loop-test step counts and pass\/fail limits are not invented here — follow the method you are working to and the supplied manual.\u003c\/p\u003e\n\n\n\u003ch2\u003eEarth Clamp Meter: clamp the loop before you compare to a stake-style earth tester\u003c\/h2\u003e\n\u003cp\u003eThe UT272A is built for \u003cstrong\u003eclamp-on\u003c\/strong\u003e ground-resistance readings: close the jaw around a suitable earth conductor \/ loop, select the \u003cstrong\u003eΩ\u003c\/strong\u003e path, read the English UI, then use \u003cstrong\u003eHOLD\u003c\/strong\u003e \/ \u003cstrong\u003eSAVE\u003c\/strong\u003e as the manual describes. An optional \u003cstrong\u003eA\u003c\/strong\u003e path supports leakage-current checks when the supplied manual allows it. That is a different instrument class from UT521 \/ UT522 stake-style digital earth testers and from UT523A’s ρEARTH \/ REARTH \/ EARTH VOLTAGE dial — confirm the face silk \u003cem\u003eUT272A Earth Clamp Meter\u003c\/em\u003e, the English UI \u003cstrong\u003e10.0 Ω \/ 1.00 Ω\u003c\/strong\u003e, and jaw silk \u003cstrong\u003eCAT IV 300V\u003c\/strong\u003e before you compare prices or procedures. This page does not invent jaw opening millimetres, ring-check step counts or legal pass\/fail limits — follow the method you are working to and the supplied manual. Confirm kit contents on this buying page before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Earth Clamp Meter — clamp-on ground resistance (optional A path per manual)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT272A Earth Clamp Meter\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: 10.0 Ω (raw_1\/2) · 1.00 Ω (raw_4)\u003c\/li\u003e\n\u003cli\u003eKeys: yellow\/orange power · blue HOLD (backlight icon) · Ω · A · OK · READ · ↑\/↓ (CLEAR) · SAVE\u003c\/li\u003e\n\u003cli\u003eFace print: APO\u003c\/li\u003e\n\u003cli\u003eJaw: trigger open\/close · jaw silk CAT IV 300V (priority captures raw_1\/raw_2; shop_note CAT III 300V overridden by readable jaw silk)\u003c\/li\u003e\n\u003cli\u003eMeasuring range (supplier attribute): 0 Ω ~ 2000 Ω\u003c\/li\u003e\n\u003cli\u003eCurrent range (supplier attribute): 0 A ~ 1 A\u003c\/li\u003e\n\u003cli\u003eTesting voltage (supplier attribute): 5 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance (supplier attribute): \u0026gt; 1 MΩ\u003c\/li\u003e\n\u003cli\u003eAccuracy class (supplier attribute): listed on source page as ±(0.01%+1) — treated as uncertain; not used as a selling claim\u003c\/li\u003e\n\u003cli\u003ePower (back silk \/ mould): AA 1.5V ×4\u003c\/li\u003e\n\u003cli\u003eBack marks (raw_3): CE · ETL · no model text — support image only\u003c\/li\u003e\n\u003cli\u003eKit \/ weight: confirm on this buying page (freight estimate 1.30 kg is not silk net mass)\u003c\/li\u003e\n\u003cli\u003eJaw opening size \/ loop-check steps \/ pass-fail limits: follow the method and supplied manual — not invented here\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003ch2\u003eHow to take a useful reading\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the earth conductor \/ loop under test is safe to approach and that the method you are following allows a clamp-on ground-resistance (or leakage-current) check at this point. Observe the warnings in the supplied manual and jaw silk \u003cstrong\u003eCAT IV 300V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSelect the \u003cstrong\u003eΩ\u003c\/strong\u003e path for ground resistance — or the \u003cstrong\u003eA\u003c\/strong\u003e path only when the manual allows a leakage-current check. Do not invent loop-test step counts or pass\/fail limits on this page. Do not borrow UT521 \/ UT522 stake-method expectations or UT523A ρEARTH \/ REARTH dial paths.\u003c\/li\u003e\n\u003cli\u003eOpen the jaw with the trigger, seat the clamp fully around the conductor \/ loop, and close the jaw so the reading path is complete.\u003c\/li\u003e\n\u003cli\u003eRead the English UI (\u003cstrong\u003e10.0 Ω\u003c\/strong\u003e \/ \u003cstrong\u003e1.00 Ω\u003c\/strong\u003e class on this capture). Use blue \u003cstrong\u003eHOLD\u003c\/strong\u003e (backlight as marked), \u003cstrong\u003eOK\u003c\/strong\u003e, \u003cstrong\u003eREAD\u003c\/strong\u003e, ↑ \/ ↓ \/ \u003cstrong\u003eCLEAR\u003c\/strong\u003e and \u003cstrong\u003eSAVE\u003c\/strong\u003e as the manual describes when you need to hold, recall, clear or store.\u003c\/li\u003e\n\u003cli\u003eRecord path (Ω or A), clamp point identity and the reading with the method reference. This page does not declare a legal pass\/fail for the installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut272a-set-ohm-path-before-you-read-the-clamp\"\u003eUNI-T UT272A: Set Ω Path Before You Read the Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT272A\u003c\/li\u003e\n\u003cli\u003eType: Earth Clamp Meter (clamp-on ground resistance; optional A path per manual)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT272A Earth Clamp Meter\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: 10.0 Ω · 1.00 Ω\u003c\/li\u003e\n\u003cli\u003eKeys: yellow\/orange power · blue HOLD (backlight icon) · Ω · A · OK · READ · ↑\/↓ (CLEAR) · SAVE\u003c\/li\u003e\n\u003cli\u003eFace print: APO\u003c\/li\u003e\n\u003cli\u003eJaw silk (readable on priority captures): CAT IV 300V\u003c\/li\u003e\n\u003cli\u003eMeasuring range (supplier attribute): 0 Ω ~ 2000 Ω\u003c\/li\u003e\n\u003cli\u003eCurrent range (supplier attribute): 0 A ~ 1 A\u003c\/li\u003e\n\u003cli\u003eTesting voltage (supplier attribute): 5 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance (supplier attribute): \u0026gt; 1 MΩ\u003c\/li\u003e\n\u003cli\u003eAccuracy class (supplier attribute): source lists ±(0.01%+1) — treated as uncertain; not emphasised\u003c\/li\u003e\n\u003cli\u003ePower: AA 1.5V ×4 (battery-door mould \/ silk on back)\u003c\/li\u003e\n\u003cli\u003eKit weight: confirm on this buying page (do not treat freight estimate as silk net mass)\u003c\/li\u003e\n\u003cli\u003eJaw opening \/ loop-check steps \/ pass-fail limits: follow the method you are working to and the supplied manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm batteries, case and any kit shown on this buying page before ordering. Follow the supplied manual for operating limits and safety warnings. Do not treat this page as UT272+, UT275 \/ UT275A, UT278A \/ B, UT270+ \/ UT273+, UT521, UT522 or UT523A. Clamp geometry and loop-test schedules are not invented here — use the manual and the method you are following.\u003c\/p\u003e\n\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\n\u003cp\u003eGet to know the UNI-T UT272A — Earth Clamp Meter layout, clamp-on Ω path before you compare to a stake-style earth tester, optional A path, jaw silk CAT IV 300V, and how it differs from UT272+ \/ UT275* \/ UT278* \/ UT521 \/ UT522 \/ UT523A. \u003ca href=\"\/pages\/learn-uni-t-ut272a\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\n\n\n\u003ch3\u003eWhat does jaw silk CAT IV 300V on the UT272A mean?\u003c\/h3\u003e\n\u003cp\u003ePriority captures (raw_1 \/ raw_2) show jaw-side silk CAT IV 300V. Treat that as the marking on this capture and still follow all markings on the unit and the supplied manual for the installation class you are working in. This page does not invent a higher category or a whole-system rating. (Shop note recorded CAT III 300V; readable jaw silk on disk overrides for copy.)\u003c\/p\u003e\n\n\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What does the UNI-T UT272A measure?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It is a clamp-on Earth Clamp Meter for ground-resistance checks on suitable loops (main path Ω). An optional A path supports leakage-current checks when the supplied manual allows it. That is a different instrument class from stake-style UT521 \/ UT522 digital earth testers and from UT523A’s Earth-ρ dial.\"}},{\"@type\":\"Question\",\"name\":\"How is the UNI-T UT272A different from UT521 \/ UT522 \/ UT523A?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"UT272A  clamps the conductor \/ loop — English UI 10.0 Ω \/ 1.00 Ω, jaw silk CAT IV 300V. UT521  and UT522  are stake-style digital earth testers. UT523A  is an Earth-ρ Tester with ρEARTH \/ REARTH \/ EARTH VOLTAGE. Do not share photos, ranges or procedures across these models.\"}},{\"@type\":\"Question\",\"name\":\"What is the Ω path versus the A path on the UNI-T UT272A?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ω is the clamp-on ground-resistance path (English UI Ω class on this capture). A is a current path for leakage-current style checks when the manual allows it. Select the path that matches the check you need before you treat a number as meaningful.\"}},{\"@type\":\"Question\",\"name\":\"What does jaw silk CAT IV 300V on the UNI-T UT272A mean?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Priority captures (raw_1 \/ raw_2) show jaw-side silk CAT IV 300V. Treat that as the marking on this capture and still follow all markings on the unit and the supplied manual for the installation class you are working in. This page does not invent a higher category or a whole-system rating.\"}},{\"@type\":\"Question\",\"name\":\"How is the UNI-T UT272A different from UT272+ \/ UT275 \/ UT278 \/ UT270+?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"UT272A is this Earth Clamp Meter page only. UT272+, UT275 \/ UT275A, UT278A \/ B and UT270+ \/ UT273+ are different models and must not share photos or copy. Confirm face silk UT272A Earth Clamp Meter and English UI 10.0 Ω \/ 1.00 Ω before you buy.\"}},{\"@type\":\"Question\",\"name\":\"Does the UNI-T UT272A page give jaw opening size or loop pass\/fail limits?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Jaw opening millimetres, ring-check \/ loop-test step counts and legal pass\/fail limits stay with the method you are working to and the supplied manual — not with this page.\"}},{\"@type\":\"Question\",\"name\":\"What batteries does the UNI-T UT272A take, and how much does it weigh?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Back mould \/ silk shows AA 1.5V ×4. Confirm batteries and any kit on this buying page. Instrument \/ kit weight is confirmed on this buying page — this page does not state a silk meter-only net mass (freight estimate 1.30 kg is not silk net weight).\"}},{\"@type\":\"Question\",\"name\":\"Can I use HOLD and SAVE on the UNI-T UT272A?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — blue HOLD (with backlight icon) and SAVE are on the face, with READ, OK, ↑ \/ ↓ and silk CLEAR. Use them as the supplied manual describes; this page does not invent memory-capacity marketing claims.\"}},{\"@type\":\"Question\",\"name\":\"Is UK delivery free for the UNI-T UT272A?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. \"}}]}\u003c\/script\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44850545819707,"sku":"EKO-UT272A","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT272A_clean_en_1.jpg?v=1793696896","url":"https:\/\/ekodeluxe.co.uk\/products\/uni-t-ut272a-earth-clamp-meter","provider":"EkoDeluxe","version":"1.0","type":"link"}