{"product_id":"uni-t-ut206a-plus-clamp-meter","title":"UNI-T UT206A+ Clamp Meter","description":"\u003cdiv class=\"eko-pdp\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT206A+\u003c\/strong\u003e is a digital clamp meter for \u003cstrong\u003e1000 A AC\u003c\/strong\u003e with a \u003cstrong\u003e6000-count\u003c\/strong\u003e display. Face silk: \u003cem\u003eUNI-T\u003c\/em\u003e, \u003cem\u003eUT206A+\u003c\/em\u003e, \u003cem\u003e1000A AC Clamp Meter\u003c\/em\u003e, \u003cem\u003e6000 Counts\u003c\/em\u003e. The rotary clamp-current position is labelled \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e, with dial \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e for non-contact voltage prompting. Jaw \/ face safety markings include \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e and \u003cstrong\u003eCAT II 1000 V\u003c\/strong\u003e, with jaw current silk \u003cstrong\u003e1000 A\u003c\/strong\u003e. English UI example on the display: \u003cstrong\u003e6.099 \/ DC \/ V \/ AUTO\u003c\/strong\u003e. Lead \/ dial paths cover AC voltage \/ frequency, the ohms family, capacitance, frequency \/ duty and temperature (°C \/ °F). Face keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e, \u003cstrong\u003eREL\u003c\/strong\u003e (with backlight) and \u003cstrong\u003eMax \/ Min\u003c\/strong\u003e, plus a side \u003cstrong\u003eHOLD\u003c\/strong\u003e. UK price \u003cstrong\u003e\u003c\/strong\u003e, free delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e bare UT206 \/ UT206A (same-batch HOLD — do not list), not UT206C (pending), not UT205A+ (, 4000 counts, no Inrush \/ NCV silk on that face), not UT205 \/ UT205A \/ UT205E. This page is the \u003cstrong\u003eUT206A+\u003c\/strong\u003e only — a \u003cstrong\u003e1000 A AC\u003c\/strong\u003e clamp with \u003cstrong\u003e6000 counts\u003c\/strong\u003e, dial \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e and \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e, English UI \u003cstrong\u003e6.099 \/ DC \/ V \/ AUTO\u003c\/strong\u003e, face \u003cstrong\u003eSELECT \/ REL \/ Max Min\u003c\/strong\u003e, and jaw \/ face markings \u003cstrong\u003eCAT III 600 V \/ CAT II 1000 V\u003c\/strong\u003e. Do not use 205A+ \/ 206 \/ A \/ C co-branded images or another UT206-series photo for ranges or accessories.\u003c\/p\u003e\n\u003ch2\u003e1000 A AC clamp with 6000 counts, Inrush 1000A~, NCV and English UI 6.099 \/ DC \/ V \/ AUTO\u003c\/h2\u003e\n\u003cp\u003eThe UT206A+ suits single-conductor AC current and inrush checks on the \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e dial position when the expected load sits inside the listed span. The English display example shows \u003cstrong\u003e6.099\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e, \u003cstrong\u003eV\u003c\/strong\u003e and \u003cstrong\u003eAUTO\u003c\/strong\u003e — that is a DC \/ voltage \/ auto-range UI style on this face, not a clamp-amps or inrush reading by itself. Dial \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e prompts for AC electric field presence; it does not prove isolation. Lead and dial functions extend to AC voltage \/ frequency, the ohms family, capacitance, frequency \/ duty and temperature. Follow the manual for SELECT, REL, Max \/ Min, side HOLD, Inrush behaviour, NCV behaviour, category limits and lead use. No True RMS silk is claimed on this page — do not invent one from sibling models.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current \/ inrush: rotary \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e (jaw silk \u003cstrong\u003e1000 A\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003eDisplay class: \u003cstrong\u003e6000\u003c\/strong\u003e counts (face silk \u003cem\u003e6000 Counts\u003c\/em\u003e; English UI example peaking at \u003cstrong\u003e6.099\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003eFace silk: \u003cem\u003eUNI-T\u003c\/em\u003e · \u003cem\u003eUT206A+\u003c\/em\u003e · \u003cem\u003e1000A AC Clamp Meter\u003c\/em\u003e · \u003cem\u003e6000 Counts\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face on this exact capture): \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e · \u003cstrong\u003eCAT II 1000 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e6.099\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e · \u003cstrong\u003eV\u003c\/strong\u003e · \u003cstrong\u003eAUTO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial includes: OFF · \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e · Hz \/ V~ · Ω \/ diode \/ continuity \/ capacitance · Hz % · °C \/ °F · \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFace keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e · \u003cstrong\u003eREL\u003c\/strong\u003e (backlight) · \u003cstrong\u003eMax \/ Min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSide control: \u003cstrong\u003eHOLD\u003c\/strong\u003e (torch \/ flashlight icon as on this capture)\u003c\/li\u003e\n\u003cli\u003eInputs: COM and VΩHz measurement jack as marked on the face\u003c\/li\u003e\n\u003cli\u003eBattery (rear door silk on this capture): \u003cstrong\u003e2 × 1.5 V AAA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): \u003cstrong\u003e240 g\u003c\/strong\u003e (0.24 kg)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp\u003c\/li\u003e\n\u003cli\u003eNo True RMS claim on this page — do not copy True RMS wording from UT216* \/ UT213B \/ UT200* pages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to set Inrush before you read the peak\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the expected AC current \/ starting surge against the listed \u003cstrong\u003e1000 A AC\u003c\/strong\u003e span, then turn the dial to \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e only when access is safe — Max \/ Min or a frozen peak does not mean “any dial position is already an inrush reading”.\u003c\/li\u003e\n\u003cli\u003eTreat a screen example showing \u003cstrong\u003e6.099 \/ DC \/ V \/ AUTO\u003c\/strong\u003e as a DC \/ voltage \/ auto-range UI style on this face, not as proof that the jaw is already reading amps or capturing inrush.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use face \u003cstrong\u003eMax \/ Min\u003c\/strong\u003e or \u003cstrong\u003eREL\u003c\/strong\u003e only as the manual describes for the function you selected, and side \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value. Follow the manual for how \u003cstrong\u003eInrush\u003c\/strong\u003e captures the starting surge on this model.\u003c\/li\u003e\n\u003cli\u003eMatch the installation to the jaw \/ face markings \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e \/ \u003cstrong\u003eCAT II 1000 V\u003c\/strong\u003e on this exact meter — a 1000 A current span does not replace category matching. Treat dial \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e as a prompt only, never as isolation proof.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut206a-plus-set-inrush-before-you-read-the-peak\"\u003eUNI-T UT206A+: Set Inrush Before You Read the Peak\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT206A+\u003c\/li\u003e\n\u003cli\u003eType: digital clamp meter (1000 A AC · Inrush)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 6000\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · UT206A+ · 1000A AC Clamp Meter · 6000 Counts\u003c\/li\u003e\n\u003cli\u003eAC current \/ inrush: listed 1000 A AC on Inrush 1000A~\u003c\/li\u003e\n\u003cli\u003eNCV: dial NCV Lo Hi (prompt only — not isolation proof)\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 6.099 \/ DC \/ V \/ AUTO\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: AC voltage \/ frequency, resistance \/ diode \/ continuity, capacitance, frequency \/ duty (Hz %), temperature (°C \/ °F)\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, REL (backlight), Max \/ Min; side HOLD\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face on this exact capture): CAT III 600 V · CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eInputs: COM and VΩHz measurement jack as marked on the face\u003c\/li\u003e\n\u003cli\u003eBattery (rear door silk on this capture): 2 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): 240 g\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003cli\u003eTrue RMS: not claimed on this page — do not invent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, any hard case \/ kit shown on this buying page and the English manual before ordering. Follow the supplied manual for accuracy conditions, Inrush timing behaviour, NCV behaviour and measurement-category suitability. Do not treat this page as UT206, UT206A, UT206C, UT205A+, UT205, UT205A, UT205E, UT216A\/B\/C or UT200A+\/UT200B+. Jaw opening size and numeric accuracy tolerances are not invented here — use the manual and the markings on your unit.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cp\u003eGet to know the UNI-T UT206A+ — 1000 A AC, 6000 counts, Inrush 1000A~, NCV, English UI 6.099 \/ DC \/ V \/ AUTO, CAT III 600 V markings and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut206a-plus\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat AC current does the UT206A+ list?\u003c\/h3\u003e\n\u003cp\u003eListed 1000 A AC on the rotary Inrush 1000A~ position, with jaw silk 1000 A. It is a 1000 A AC clamp with an Inrush path, not a DC-current clamp and not the UT205A+ \/ bare UT206 layout.\u003c\/p\u003e\n\u003ch3\u003eWhat does Inrush 1000A~ do on this meter?\u003c\/h3\u003e\n\u003cp\u003eIt is the rotary clamp-current \/ inrush position silk-printed on this exact face. Set Inrush 1000A~ before treating a peak or Max\/Min value as a starting-surge reading. Follow the supplied manual for capture timing and accuracy conditions — do not invent Inrush behaviour from sibling pages.\u003c\/p\u003e\n\u003ch3\u003eWhat does the English UI 6.099 \/ DC \/ V \/ AUTO mean on this page?\u003c\/h3\u003e\n\u003cp\u003eIt is the English display example on this exact face — a DC \/ voltage \/ auto-range readout style. It is not a screen-size claim and not, by itself, a clamp-amps or inrush reading. Set Inrush 1000A~ before treating the jaw path as AC current.\u003c\/p\u003e\n\u003ch3\u003eDoes NCV prove a circuit is safe \/ isolated?\u003c\/h3\u003e\n\u003cp\u003eNo. Dial NCV Lo Hi is a non-contact voltage prompt only. It does not prove isolation, does not measure amps, and does not authorise live work. Use the correct safe-isolation equipment and procedure for the installation.\u003c\/p\u003e\n\u003ch3\u003eDoes it measure DC current? Is it True RMS?\u003c\/h3\u003e\n\u003cp\u003eNo DC current clamp range is listed on this model — it is a 1000 A AC clamp (Inrush 1000A~). No True RMS claim is made on this page from face silk. Do not copy True RMS wording from UT216*, UT213B or UT200* pages. Follow the manual’s accuracy conditions for the function and range you select.\u003c\/p\u003e\n\u003ch3\u003eHow is UT206A+ different from UT205A+ and from UT206 \/ UT206A \/ UT206C?\u003c\/h3\u003e\n\u003cp\u003eThis page is UT206A+ only. Confirmed differences vs UT205A+  include 6000 counts (vs 4000), dial Inrush 1000A~ and NCV Lo Hi (UT205A+ face uses 1000 A~ without Inrush \/ NCV silk on that capture), English UI 6.099 \/ DC \/ V \/ AUTO (vs 4.099 \/ DC \/ AUTO), and temperature °C \/ °F on this dial. Bare UT206 \/ UT206A are same-batch HOLD (do not list or borrow their photos). UT206C is pending — do not use A\/C combo posters. Price on this page: .\u003c\/p\u003e\n\u003ch3\u003eIs UK delivery free?\u003c\/h3\u003e\n\u003cp\u003eYes. Free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. \u003c\/p\u003e\n\n\u003ch2\u003eLearn more\u003c\/h2\u003e\n\u003cp\u003eRead the \u003ca href=\"\/pages\/learn-uni-t-ut206a-plus\"\u003eUNI-T UT206A+ overview\u003c\/a\u003e and the field guide \u003ca href=\"\/blogs\/guides\/uni-t-ut206a-plus-set-inrush-before-you-read-the-peak\"\u003eSet Inrush Before You Read the Peak\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849737793595,"sku":"EKO-UT206A+","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT206A_plus_clean_en_1.jpg?v=1793689143","url":"https:\/\/ekodeluxe.co.uk\/products\/uni-t-ut206a-plus-clamp-meter","provider":"EkoDeluxe","version":"1.0","type":"link"}