{"product_id":"uni-t-ut171a-industrial-true-rms-multimeter","title":"UNI-T UT171A Industrial True RMS Multimeter","description":"\u003cp\u003eThe UNI-T UT171A is an industrial True RMS multimeter with a 40000-count LCD and STORE, RECALL, MAX\/MIN and V.F.C. controls. It provides voltage, current, resistance, capacitance, frequency, diode and continuity functions and uses four AA batteries.\u003c\/p\u003e\n\n\u003cp\u003eThe UNI-T UT171A is an industrial True RMS digital multimeter for handheld voltage, current, resistance, capacitance, frequency, diode, continuity and NCV checks — not a UT171B\/C co-sell, not a bare UT171 cage page, and not a UT136* \/ UT890D+ \/ UT61E+ family listing. Face silk: UNI-T · Industrial Digital Multimeter · UT171A. Panel mark \u003cstrong\u003e40000 Counts\u003c\/strong\u003e and \u003cstrong\u003eTrue RMS\u003c\/strong\u003e. Soft keys on this capture: RANGE · STORE · RECALL · MAX MIN · Esc · REL · Hz% · Ok \/ Select V.F.C. Rotary dial: OFF · V.F.C\/Hz · V~ · mV\/Hz · Ω \/ capacitance \/ diode \/ continuity · Hz% · A · mA · μA · NCV. Jacks: 10A MAX · µA mA · COM · V Ω Hz. Body safety silk: CAT III 1000V \/ CAT IV 600V. Power: \u003cstrong\u003eAA ×4\u003c\/strong\u003e (visible in kit capture) — not the lithium pack used on UT171B\/C. Size about 206 × 95 × 55 mm; net weight \u003cstrong\u003e0.384 kg\u003c\/strong\u003e (weight_est=N). Supplier attributes (not face silk \/ not legal pass-fail): Accuracy Class ±(0.5%+3), measuring voltage 400 mV–1000 V, current 400 µA–10 A. Confirm kit contents and weight on this buying page and in the supplied manual.  free delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot UT171B \/ UT171C\u003c\/strong\u003e (do not co-sell; A = \u003cstrong\u003e40000 counts · AA\u003c\/strong\u003e; B\/C = \u003cstrong\u003e60000 counts · lithium\u003c\/strong\u003e; C = \u003cstrong\u003eOLED\u003c\/strong\u003e — A face legend is Industrial Digital Multimeter \/ LCD class, \u003cstrong\u003enot OLED\u003c\/strong\u003e). A shared series booklet cover “UT171A\/B\/C” or an A\/B\/C comparison sheet is not a second buyable model on this page. Not bare UT171, not UT136*, not UT890D+, and not UT61E+. Do not share photos, ranges or procedures with UT171B\/C \/ bare UT171 \/ other families. Follow the supplied manual for probe paths, fuse limits and category warnings.\u003c\/p\u003e\n\n\u003ch2\u003eIndustrial True RMS multimeter: confirm UT171A 40000 · AA — not UT171B\/C\u003c\/h2\u003e\n\u003cp\u003eThe UT171A is built for industrial handheld True RMS checks across the listed voltage, current, resistance, capacitance, frequency, diode, continuity and NCV paths. Face silk marks UNI-T UT171A with 40000 Counts and True RMS. Power on, pick the dial path, seat the leads in the correct jacks, then read the display. Use RANGE \/ STORE \/ RECALL \/ MAX MIN \/ REL \/ Hz% \/ Select V.F.C as the supplied manual describes. That is a different listing identity from UT171B\/C (60000 · lithium; C OLED), from bare UT171, and from UT136* \/ UT890D+ \/ UT61E+. Confirm the face silk UT171A, the 40000-count mark, AA power, and body CAT III 1000V \/ CAT IV 600V before you compare prices or procedures. This page does not invent fuse schedules or legal pass\/fail limits — follow the method you are working to and the supplied manual. Confirm kit contents on this buying page before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Industrial True RMS digital multimeter\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · Industrial Digital Multimeter · UT171A\u003c\/li\u003e\n\u003cli\u003eDisplay: \u003cstrong\u003e40000 Counts\u003c\/strong\u003e (LCD industrial face — not OLED)\u003c\/li\u003e\n\u003cli\u003eTrue RMS: Yes (face mark)\u003c\/li\u003e\n\u003cli\u003eKeys: RANGE · STORE · RECALL · MAX MIN · Esc · REL · Hz% · Ok \/ Select V.F.C\u003c\/li\u003e\n\u003cli\u003eDial paths: OFF · V.F.C\/Hz · V~ · mV\/Hz · Ω \/ capacitance \/ diode \/ continuity · Hz% · A · mA · μA · NCV\u003c\/li\u003e\n\u003cli\u003eJacks: 10A MAX · µA mA · COM · V Ω Hz\u003c\/li\u003e\n\u003cli\u003eBody safety silk: CAT III 1000V \/ CAT IV 600V\u003c\/li\u003e\n\u003cli\u003ePower: AA ×4 (≠ B\/C lithium)\u003c\/li\u003e\n\u003cli\u003eVoltage (supplier attribute): 400 mV–1000 V\u003c\/li\u003e\n\u003cli\u003eCurrent (supplier attribute): 400 µA–10 A (respect fuse \/ time limits in the manual)\u003c\/li\u003e\n\u003cli\u003eSize \/ weight: about 206 × 95 × 55 mm · \u003cstrong\u003e0.384 kg\u003c\/strong\u003e (weight_est=N)\u003c\/li\u003e\n\u003cli\u003eStrong contrast: UT171A only — do not co-sell UT171B\/C; 40000·AA ≠ 60000·lithium; not OLED; do not share photos with bare UT171 \/ UT136* \/ UT890D+ \/ UT61E+; series A\/B\/C booklet cover is not a co-sell\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to take a useful reading\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the circuit under test is safe to approach and that the method you are following allows a probe or NCV check at this point. Observe the warnings in the supplied manual and all CAT \/ fuse markings on the unit.\u003c\/li\u003e\n\u003cli\u003ePower on. Select the dial path (V.F.C \/ V~ \/ mV \/ Ω \/ capacitance \/ Hz% \/ current \/ NCV \/ …) as the supplied manual describes — before you treat a number as meaningful. Do not invent fuse schedules or pass\/fail limits on this page. Do not borrow UT171B\/C OLED or 60000-count layouts, bare UT171 expectations, or UT136* \/ UT890D+ \/ UT61E+ procedures as if they were this meter.\u003c\/li\u003e\n\u003cli\u003eSeat leads in the correct jacks (COM · V Ω Hz · µA mA · 10A as required). Respect fused limits printed on the face and in the manual.\u003c\/li\u003e\n\u003cli\u003eRead the display. Use RANGE, HOLD-related soft keys, MAX MIN, REL, STORE \/ RECALL and Select V.F.C as the manual describes. For NCV, follow the dedicated dial position and the manual — do not treat an NCV indication as a full live-safe certificate.\u003c\/li\u003e\n\u003cli\u003eRecord path context, jack identity and the reading with the method reference. This page does not declare a legal pass\/fail for the installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT171A\u003c\/li\u003e\n\u003cli\u003eType: Industrial True RMS digital multimeter\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · Industrial Digital Multimeter · UT171A\u003c\/li\u003e\n\u003cli\u003eDisplay: 40000 Counts (not OLED — OLED is UT171C)\u003c\/li\u003e\n\u003cli\u003eTrue RMS: Yes\u003c\/li\u003e\n\u003cli\u003eKeys: RANGE · STORE · RECALL · MAX MIN · Esc · REL · Hz% · Ok \/ Select V.F.C\u003c\/li\u003e\n\u003cli\u003eDial: OFF · V.F.C\/Hz · V~ · mV\/Hz · Ω \/ capacitance \/ diode \/ continuity · Hz% · A · mA · μA · NCV\u003c\/li\u003e\n\u003cli\u003eJacks: 10A MAX · µA mA · COM · V Ω Hz\u003c\/li\u003e\n\u003cli\u003eBody safety silk: CAT III 1000V \/ CAT IV 600V\u003c\/li\u003e\n\u003cli\u003eVoltage (supplier attribute): 400 mV–1000 V\u003c\/li\u003e\n\u003cli\u003eCurrent (supplier attribute): 400 µA–10 A\u003c\/li\u003e\n\u003cli\u003eAccuracy Class (supplier attribute): ±(0.5%+3) — not a legal pass\/fail certificate on this page\u003c\/li\u003e\n\u003cli\u003eSize \/ weight: about 206 × 95 × 55 mm · 0.384 kg (weight_est=N)\u003c\/li\u003e\n\u003cli\u003ePower: AA ×4 (≠ UT171B\/C lithium)\u003c\/li\u003e\n\u003cli\u003eNCV: yes (dedicated dial)\u003c\/li\u003e\n\u003cli\u003eKit \/ leads \/ packing: confirm on this buying page and in the supplied manual (capture shows AA cells, USB lead, test leads, bag, CD, series booklet)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eConfirm batteries, leads and any kit shown on this buying page before ordering. Follow the supplied manual for operating limits and safety warnings. Do not treat this page as UT171B, UT171C, bare UT171, UT136*, UT890D+ or UT61E+. Fuse schedules and pass\/fail limits are not invented here — use the manual and the method you are following.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available. Europe: free delivery likewise; displayed EUR price follows the store Markets catalog (not a handwritten euro figure on learn\/guides pages).\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/pages\/learn-uni-t-ut171a\"\u003eGet to know the UNI-T UT171A\u003c\/a\u003e — 40000-count industrial True RMS layout, AA power, NCV, CAT III 1000V \/ CAT IV 600V, and how it differs from UT171B\/C \/ bare UT171 \/ other DMM families. Learn more →\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/blogs\/guides\/uni-t-ut171a-confirm-40000-aa-not-ut171b-c\"\u003eConfirm UT171A 40000 · AA — not UT171B\/C\u003c\/a\u003e — keep model identity clear before you probe. Guide →\u003c\/p\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What does the UT171A measure?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Industrial True RMS digital multimeter for listed voltage, current, resistance, capacitance, frequency, diode, continuity and NCV paths. Different listing from UT171B\/C, bare UT171, and UT136* \/ UT890D+ \/ UT61E+.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is this the same as UT171B or UT171C?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"No. UT171A only: 40000 counts · AA ×4. UT171B\/C are 60000 · lithium; UT171C is OLED. Series A\/B\/C booklet cover is not a co-sell.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is the UT171A an OLED meter?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"No. Face legend is Industrial Digital Multimeter (LCD-class 40000 counts). OLED is UT171C contrast.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What power source does UT171A use?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"AA ×4. Hard contrast vs UT171B\/C lithium packs.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What ranges and category apply?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Supplier attributes: voltage 400 mV–1000 V, current 400 µA–10 A; Accuracy Class ±(0.5%+3) is supplier-only. Body silk CAT III 1000V \/ CAT IV 600V. Fuse limits stay with the manual.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is UK \/ Europe delivery free?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes — free UK delivery; Europe likewise per store policy.  Check the product options for the current price in your selected market.\"\n          }\n        }\n      ]\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8087403528251-isolated-resistance-bench\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: keep resistance observations reproducible\u003c\/h2\u003e\n\u003cp\u003eIsolate the component and remove stored energy before selecting resistance. Keep the component identity, input function and range with the observation; this UT171A setup does not borrow the OLED or battery specification of its siblings.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-products50-p8087403528251-isolated-resistance-bench-v1.webp?v=1794911751\" alt=\"UNI-T UT171A LCD multimeter checking a removed resistor beside a paper log\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: UNI-T UT171A LCD multimeter checking a removed resistor beside a paper log. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44852377911355,"sku":"EKO-UT171A","price":419.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/01_hero_85ba36bd-d428-460c-9a69-236197e1f4c8.jpg?v=1793704233","url":"https:\/\/ekodeluxe.co.uk\/products\/uni-t-ut171a-industrial-true-rms-multimeter","provider":"EkoDeluxe","version":"1.0","type":"link"}