UNI-T UT210E : mini-pince ampèremétrique
Prix tel qu’affiché · Taxes au paiement · Livraison gratuite RU & Europe · Expédition sous 1–2 jours ouvrés · Livraison env. 5–7 jours ouvrés après expédition
The UNI-T UT210E is a True RMS mini digital clamp meter with a 2000-count display and 100 A AC/DC current ranges (2 A / 20 A / 100 A). Face silk: UNI-T UT210E True RMS; controls include ZERO, SELECT / V.F.C and HOLD / Backlight, plus an NCV position. Listed voltage to 600 V, resistance to 20 MΩ and capacitance to about 20 mF. Price as shown; livraison gratuite RU & Europe.
Not UT210A, UT210B, UT210C or UT210D. This page is the UT210E only — do not use another UT210-series poster for ranges or accessories.
Mini jaw True RMS clamp for AC/DC work
The UT210E suits confined conductors where a ~17 mm jaw can close fully around a single suitable lead. True RMS applies to the listed AC voltage and current paths; V.F.C is available when variable-frequency interference needs filtering on AC V/A. Follow the manual for ZERO, orientation and category limits.
- AC/DC current: 2 A / 20 A / 100 A (low range resolution down to 1 mA as listed)
- AC/DC voltage: up to 600 V
- Resistance: up to 20 MΩ; capacitance: up to ~20 mF; frequency: 10 Hz–60 kHz
- True RMS; V.F.C for variable-frequency AC V/A; NCV; diode; continuity
- ZERO for DCA zero / relative on supported V/C functions; data hold; backlight; auto power off
- Jaw ~17 mm; body ~175 × 60 × 33.5 mm; weight ~170 g; power 2 × AAA
- Measurement categories listed on UNI-T series data: CAT II 600 V / CAT III 300 V — confirm leads and task before use
How to zero DC current before you clamp
- Select the DC current function and the range that fits the expected current.
- With the jaw closed and empty, follow the manual’s ZERO sequence so the baseline is near zero.
- Clamp a single suitable conductor — not an entire twin-and-earth or both go-and-return paths together.
- Keep jaw orientation consistent with the documented polarity convention; a sign change can be direction, not a failed load.
- Use V.F.C only when the AC V/A path needs the listed low-pass behaviour; long-press SELECT as the manual describes.
See also: UNI-T UT210E: Zero DC Before You Clamp.
Specifications
- Model: UNI-T UT210E
- Type: True RMS mini digital clamp meter
- Display counts: 2000
- AC/DC current: 2 A / 20 A / 100 A
- AC/DC voltage: up to 600 V
- Resistance: up to 20 MΩ
- Capacitance: up to ~20 mF
- Frequency: 10 Hz–60 kHz
- Jaw opening: ~17 mm
- Functions: True RMS, V.F.C, NCV, diode, continuity, ZERO, HOLD, backlight, auto power off
- Power: 2 × 1.5 V AAA
- Size / weight: ~175 × 60 × 33.5 mm / ~170 g
- Categories listed (series data): CAT II 600 V, CAT III 300 V
Confirm leads, bag and batteries on this buying page before ordering. Follow the supplied manual for accuracy conditions, ZERO behaviour and measurement-category suitability. This is not a 1000 A clamp.
Livraison gratuite vers le Royaume-Uni et l’Europe. Expédition sous 1–2 jours ouvrés, livraison sous 5–7 jours ouvrés. Prix tel qu’affiché ; taxes au paiement. Factures TVA disponibles le cas échéant.
FAQ
What current ranges does the UT210E list?
AC and DC current on 2 A, 20 A and 100 A ranges. Low-range resolution is listed down to 1 mA. It is not a 1000 A clamp.
Does it measure DC current?
Yes. Use the DC current function, zero with an empty closed jaw as the manual describes, then clamp a single suitable conductor with consistent orientation.
What is V.F.C on the UT210E?
V.F.C is UNI-T’s variable-frequency (low-pass) mode for suitable AC voltage and current measurements where high-frequency interference would otherwise disturb the reading. Enable it only when the task needs it; follow the SELECT / V.F.C sequence in the manual.
Is NCV proof that a circuit is safe to touch?
No. NCV is a non-contact indication aid only. Use the correct safe-isolation procedure and equipment for the installation.
Is this the same as UT210A / UT210D?
No. UT210E is a separate True RMS model with its own 100 A AC/DC and V.F.C listing. Do not apply UT210A–D poster specifications to this page.
What else can it measure with leads?
Listed functions include AC/DC voltage to 600 V, resistance to 20 MΩ, capacitance to about 20 mF, frequency 10 Hz–60 kHz, diode and continuity — subject to the manual’s ranges and leads.
La livraison est-elle gratuite ?
Oui. Livraison gratuite vers le Royaume-Uni et l’Europe. Les commandes partent généralement sous 1–2 jours ouvrés et arrivent environ 5–7 jours ouvrés après l’expédition. Prix tel qu’affiché ; taxes au paiement.
Get to know the UNI-T UT210E
jaw fit, ZERO practice, V.F.C and model distinctions before you choose. Learn more →
Spécifications techniques
| Spécification | Valeur |
| Model | UNI-T UT210E |
| Type | Mini pince multimètre numérique True RMS |
| Display counts | 2000 |
| AC/DC current | 2 A / 20 A / 100 A |
| AC/DC voltage | Jusqu’à 600 V |
| Resistance | Jusqu’à 20 MΩ |
| Capacitance | Jusqu’à ~20 mF |
| Frequency | 10 Hz–60 kHz |
| Jaw | ~17 mm |
| Functions | True RMS, V.F.C, NCV, diode, continuité, ZERO, HOLD, rétroéclairage, APO |
| Power | 2 × AAA |
| Size / weight | ~175 × 60 × 33,5 mm / ~170 g |
| Categories listed (series) | CAT II 600 V, CAT III 300 V |
Quels calibres de courant le UT210E indique-t-il ?
Courant CA et CC sur les gammes 2 A, 20 A et 100 A. La résolution de la gamme basse est indiquée jusqu’à 1 mA. Il ne s’agit pas d’une pince 1 000 A.
Mesure-t-il le courant continu ?
Oui. Utilisez la fonction de courant CC, remettez à zéro avec la mâchoire fermée et vide comme le décrit le manuel, puis serrez un seul conducteur adapté en conservant une orientation cohérente.
À quoi sert V.F.C sur le UT210E ?
V.F.C est le mode à fréquence variable (passe-bas) de UNI-T pour les mesures adaptées de tension et de courant CA lorsque des interférences haute fréquence pourraient perturber la mesure. Activez-le uniquement lorsque la tâche le nécessite ; suivez la séquence SELECT / V.F.C du manuel.
La détection NCV prouve-t-elle qu’un circuit peut être touché sans danger ?
Non. Le NCV est uniquement une aide d’indication sans contact. Utilisez la procédure et l’équipement d’isolement sécurisé adaptés à l’installation.
S’agit-il du même modèle que l’UT210A / UT210D ?
Non. Le UT210E est un modèle True RMS distinct, avec ses propres données 100 A CA/CC et V.F.C. N’appliquez pas à cette page les spécifications des affiches UT210A–D.
Quelles autres mesures peut-il effectuer avec les cordons ?
Les fonctions indiquées comprennent la tension CA/CC jusqu’à 600 V, la résistance jusqu’à 20 MΩ, la capacité jusqu’à environ 20 mF, la fréquence 10 Hz–60 kHz, la diode et la continuité, sous réserve des gammes et des cordons du manuel.
La livraison en France est-elle gratuite ?
Oui. La livraison est gratuite en France. Les commandes sont généralement expédiées sous 1–2 jours ouvrés et livrées environ 5–7 jours ouvrés après expédition.
Quand recevrai-je ma commande ?
Expédié sous 1 à 2 jours ouvrés. Livré 5 à 7 jours ouvrés après l’expédition.
Quelle est la politique de retour ?
Vous pouvez retourner un produit sous 30 jours. Voir notre page de retours pour les détails.
Le paiement est-il sécurisé ?
Le paiement est traité via le paiement sécurisé Shopify.
Comment contacter le support ?
Écrivez à support@ekodeluxe.co.uk.