ZOYI ZT-1000R · PRODUCT OVERVIEW

Choose the test voltage.Keep insulation and meter checks separate.

The ZT-1000R combines an insulation resistance tester with a 19999-count True RMS multimeter. Five listed insulation-test voltages span 50–1000 V, with a stated insulation resistance maximum of 20 GΩ.

ZOYI ZT-1000R product view
5 settings50 / 100 / 250 / 500 / 1000 V
20 GΩListed insulation maximum
19999 countsMeter display capacity
True RMSListed meter method

UNDERSTAND THE INSTRUMENT

Five test voltages with a separate meter workflow.

The ZT-1000R combines an insulation resistance tester with a 19999-count True RMS multimeter. Five listed insulation-test voltages span 50–1000 V, with a stated insulation resistance maximum of 20 GΩ.

01

Match voltage to the equipment

Choose the insulation-test voltage from the equipment instructions and procedure. Higher voltage is not automatically the better test.

02

Keep resistance in its test context

Record voltage, connection points, duration and environmental conditions with the insulation reading. The maximum display does not establish equal accuracy across all ranges.

03

Change deliberately to meter functions

A combined instrument has distinct test setups. Recheck switch position, terminals and leads before moving between insulation and normal meter measurements.

ZOYI ZT-1000R functions and display

FROM FEATURES TO TASKS

Record the setup with the insulation result.

Match the method, setup and record to the measurement you need.

Prepare an isolated insulation test

Identify the circuit and sensitive connected equipment, then follow the required isolation, test and discharge procedure.

Repeat a documented equipment check

Use comparable voltage, duration and connections where the method calls for trending.

Confirm a separate electrical reading

Choose the supported meter function and limits independently from the insulation setting.

BEFORE YOU CHOOSE

Find the fit for your work.

A good shortlist for

  • Competent users needing insulation and meter functions together.
  • Equipment procedures using the listed test-voltage steps.
  • Documented insulation readings with consistent test conditions.

Check these limits first

  • PI/DAR functions are not established in the reviewed information.
  • No complete installation-certification capability is asserted.
  • Insulation testing must suit disconnected equipment and its electronics.

THE ESSENTIALS

Key specifications.

Specification ZOYI ZT-1000R
Test voltages 50 / 100 / 250 / 500 / 1000 V
Insulation maximum 20 GΩ listed
Meter display 19999 counts
Meter method True RMS listed
Instrument type Insulation tester / multimeter
Test record Voltage, duration, connections and conditions

Specifications describe the reviewed model and source. Follow the supplied manual for range, accuracy conditions and operating limits. Confirm the current kit and accessories before ordering.

GET THE CONTEXT

Learn before you choose.

These guides explain the wider measurement questions behind the product.

A FEW MORE DETAILS

Your questions, answered.

Does it have 50 V and 100 V settings?

Yes. Both appear in the reviewed five-step voltage list. Choose the setting required by the equipment procedure.

Are PI and DAR included?

They are not established by the reviewed ZT-1000R information. Confirm separately if they are essential.

Can insulation mode be used on a live circuit?

Follow the supplied isolation and discharge procedure. Do not apply an insulation test to an energised circuit.

Explore the ZT-1000R buying options.

Check the buying page for the current price, availability, version, kit contents and delivery information.