PRODUCT OVERVIEW
Power from the panel.Capture Pmax in one view.
The UNI-T UT673PV is a Solar MPPT Meter for photovoltaic modules. You connect MC4 leads to a suitable panel, let the meter power up from that panel, then run AUTO or MANUAL MPPT so Pmax, Vmp, Imp, Voc and Isc appear together. That workflow is different from a general multimeter check, a clamp-only current reading, or a separately listed UT673 without the PV role.

HOW TO APPROACH IT
A one-screen MPPT check for solar panels.
The UT673PV lists maximum-power capture up to 800W, voltage 12–60V, current 0–35A, MC4 leads, reverse/over protections, and data hold. Face silk: HOLD / AUTO / MANUAL · 60V MAX. Use it when the task is a module-level MPPT / Voc / Isc snapshot — not as a everyday multimeter and not on non-panel sources.
Power from the panel first
There is no battery to install for normal use. Correct MC4 mating both powers the instrument and starts the measurement path. Wrong polarity or a non-panel source is outside the listed role.
Read Pmax with Vmp and Imp together
Maximum power alone is incomplete. Keep Vmp and Imp with Pmax so you can compare modules or before/after conditions on the same irradiance day without guessing which current belonged to which power figure.
Keep MANUAL intervals honest
In MANUAL mode, wait at least 30 seconds before the next test interval. Back-to-back presses do not improve a reading and can violate the listed interval.
WHY THE METHOD MATTERS
Make polarity and panel limits part of the result.
MC4 orientation → panel power-up → AUTO/MANUAL → one-screen capture — in that order.

TYPICAL TASKS
Where this meter earns its place.
Stay on solar panels only
Back-label and UNI-T listing: For Solar Panel Test Only · 12–60V / 0–35A / 800W. Do not treat this as a battery, inverter or mains instrument.
Use HOLD when you need a still frame
After a stable sweep, HOLD freezes the on-screen set so you can note Pmax / Vmp / Imp / Voc / Isc without rewriting under glare.
Prefer AUTO when you want a hands-off sweep
AUTO MPPT runs the capture sequence for you; MANUAL is available when your procedure calls for operator-timed intervals (≥30 s between MANUAL tests).
FIT CHECK
Is this the right shortlist?
A good shortlist for
- Module-level max-power / Voc / Isc checks within the listed ranges.
- Installers and maintainers who want one screen instead of separate Voc and Isc tools for a quick panel snapshot.
- Comparative checks when irradiance, tilt and connection method stay consistent.
Check these limits first
- It is not a general multimeter and not a clamp meter substitute for non-PV work.
- Safety is solar-panel-only, max 60VDC, no measurement category (CAT 0 60V) — not CAT II/III/IV.
- Do not assume UT673 (non-PV), UT673E or LD673PV specifications apply to this page.
- Accuracy figures are listed under manufacturer conditions — follow the supplied manual for irradiance and temperature notes.
| Specification | UNI-T UT673PV |
|---|---|
| Model | UT673PV |
| Type | Solar MPPT Meter |
| Face | HOLD / AUTO / MANUAL · 60V MAX |
| On-screen | Pmax, Vmp, Imp, Voc, Isc |
| Pmax | 5–800W, ±(1.0%+10) |
| Vmp / Voc | 12–60V, ±(1.5%+5) |
| Imp / Isc | 0–35A, ±(1.5%+5) |
| Modes | Manual / Auto MPPT; Data hold |
| Manual interval | ≥30 s |
| Power | Panel-powered (no battery) |
| Leads | MC4 test leads |
| Protection | Reverse / OV / OC / OT / over-power |
| Safety | Solar panel only · max 60VDC · CAT 0 60V (no measurement category) |
| Certifications | CE, cETLus, RoHS |
| Size / weight | ~142 × 76 × 22 mm / ~154g |
Specifications describe the reviewed UNI-T model and source. Follow the supplied manual for range, accuracy conditions, connection diagrams and operating limits. Confirm the current kit on the buying page before ordering.
GET THE CONTEXT
Learn before you choose.
Start with the model-specific how-to, then widen to related tester choices if needed.
Check MC4 polarity, power from the panel, run AUTO or MANUAL, read Pmax/Vmp/Imp/Voc/Isc together — and wait ≥30 s between MANUAL tests.
Read the guide → BUYING PAGEUNI-T UT673PV Solar MPPT MeterUK stock £58.99, VAT included, free delivery. Confirm the current kit before ordering.
View product →A FEW MORE DETAILS
Your questions, answered.
Does it need a battery?
No. The meter is powered by the solar panel under test. Connect MC4 leads correctly so it can wake from the panel.
What is the MANUAL 30-second rule?
In MANUAL MPPT mode, wait at least 30 seconds between test intervals. Do not stack retests immediately.
Can I use it on a battery bank or inverter DC bus?
No. The listed role is solar-panel test only, max 60VDC, with no measurement category. Stay inside those limits.
Is this UT673, UT673E or LD673PV?
No. UT673PV is the Solar MPPT Meter on this overview. Do not mix their specifications or product images.
Ready to buy the UNI-T UT673PV?
UK stock, VAT included, free UK delivery. SKU EKO-UT673PV.
Product information: UNI-T manufacturer specifications and the EkoDeluxe product listing. Overview checked 2 November 2026. For operating instructions, use the supplied manual. Model UNI-T UT673PV · SKU EKO-UT673PV.