1Panier

PRODUCT OVERVIEW

Pick the AC range.Clamp one conductor.

The UNI-T UT200B+ is a True RMS digital clamp meter for 600 A AC current on discrete 3 A~ / 30 A~ / 600 A~ rotary ranges. Face silk reads UNI-T UT200B+, True RMS, 600A AC CLAMP METER and CAT III 600V. An English UI example on the display shows 3.099 / DC / V / AUTO. It is a different model from UT200A+ (400 A AC), UT200R and UT210E.

UNI-T UT200B+ Clamp Meter
600 AListed AC current max
3 / 30 / 600 A~Rotary AC ranges
True RMSListed AC response
UT200B+Distinct from A+ / R / UT210E

HOW TO APPROACH IT

An AC clamp with range choice up front.

Physical fit and the documented current method both matter. The UT200B+ lists lead measurements for AC/DC voltage, frequency, resistance, capacitance, diode and continuity, plus LIVE and HOLD / backlight on a handheld AAA-powered body. AC current is selected on the dial — it is not a DC-current clamp.

01

Match one suitable conductor

The jaw must close fully around a single conductor of interest. Clamping go-and-return together can cancel the field and produce a near-zero result that does not mean “no current”.

02

Pick 3 A~, 30 A~ or 600 A~ before you clamp

Estimate the load, then set the rotary range with headroom. Starting on 3 A~ when you expect tens or hundreds of amps is the wrong order. Step up only when the reading and the task justify it.

03

Keep True RMS and LIVE in proportion

True RMS applies to the listed AC paths when the waveform is not a clean sine. LIVE is an indication aid on the face controls — not proof of isolation and not a substitute for a proving unit.

WHY THE METHOD MATTERS

Match current type and range to the conductor.

Estimate load → set 3 A~ / 30 A~ / 600 A~ → clamp one conductor → note HOLD if needed.

UNI-T UT200B+ rear battery bay

TYPICAL TASKS

Where this clamp earns its place.

Plan an AC current check

Confirm expected current, choose 3 A~ / 30 A~ / 600 A~ accordingly, and verify safe access before the jaw closes.

Take a supported voltage or resistance reading

Use the supplied leads and the documented input limits. A CAT III 600 V face marking does not establish every installation category by itself.

Prepare the portable kit

Confirm two AAA cells, leads and the English manual on the buying page.

FIT CHECK

Is this the right shortlist?

A good shortlist for

  • Users who need a True RMS 600 A AC clamp with explicit 3 A~ / 30 A~ / 600 A~ ranges.
  • Tasks that stay on AC current (motors, distribution checks, service work) without needing DC current on the clamp.
  • Buyers who need more AC headroom than the 400 A UT200A+ and will confirm single-conductor technique, range choice and category limits before purchase.

Check these limits first

  • Do not invent a DC current span — this model is listed as a 600 A AC clamp.
  • Do not invent a 1000 A span.
  • Do not treat this page as the 400 A UT200A+.
  • LIVE is not isolation proof.
  • Screen value 3.099 is an English UI readout example, not a screen-size claim.
  • CAT III 600 V is the face marking — still match leads and competent procedure to the job.
  • This page is not UT200A+, UT200R or UT210E.
What matters UNI-T UT200B+
Main role True RMS AC clamp + lead measurements
Current AC only · 3 A~ / 30 A~ / 600 A~
Safety face marking CAT III 600 V
Notable controls SELECT, LIVE, HOLD / backlight
A reason to shortlist it You need a 600 A AC True RMS clamp with English UI and discrete AC ranges

Compare UT200A+ (400 A AC), UT200R or UT210E only from their own datasheets and product pages — current methods, spans and accessories differ. Do not mix A+/B+ factory combo posters.

Specification UNI-T UT200B+
Model UT200B+
Type True RMS digital clamp meter (600 A AC)
AC current 3 A~ / 30 A~ / 600 A~
Display UI (example) 3.099 / DC / V / AUTO
Lead functions AC/DC voltage, frequency (V~ / Hz), resistance, capacitance, diode, continuity
Controls SELECT, LIVE, HOLD / backlight
Safety marking (face) CAT III 600 V
Power 2 × AAA
Current method AC clamp only (no DC current range)

Specifications describe the reviewed UNI-T UT200B+ face silk and listing sources. Follow the supplied manual for accuracy conditions and operating limits. Confirm the current kit on the buying page (£59.05) before ordering.

GET THE CONTEXT

Learn before you choose.

Start with the model-specific how-to, then open the buying page for kit and price.

A FEW MORE DETAILS

Your questions, answered.

Can it measure DC current?

No. UNI-T lists this model as a 600 A AC clamp. DC on the English display example refers to DC voltage (and related lead work), not clamp DC current.

Does it have True RMS?

Yes. Face marking lists True RMS for the relevant AC paths. Check the manual’s accuracy conditions for the waveform you intend to measure.

Is LIVE always required?

No. Use LIVE only as the manual describes for indication. It is not a default substitute for safe isolation.

Is this UT200A+ or UT210E?

No. UT200B+ is a separate model (600 A AC). Do not apply A+ combo posters or UT210E AC/DC mini-clamp specifications to this overview.

Ready to buy the UNI-T UT200B+?

UK stock, VAT included, free UK delivery. SKU EKO-UT200B+.

Buy · £59.05

Product information: UNI-T face markings / manufacturer-style attributes and the EkoDeluxe product listing. Overview checked 3 November 2026. For operating instructions, use the supplied manual. Model UNI-T UT200B+ · SKU EKO-UT200B+.