A screen reading “CORRECT” needs to be interpreted within the tests the instrument actually performs. The ZOYI ZT-E10 has a UK plug, an English colour display and power from two AAA batteries. Its listing shows socket-tester, CORRECT and NCV labels.
Those labels do not make a quick plug-in indication a complete electrical-installation assessment.

ZOYI ZT-E10 supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Confirm suitability before use
Check the current instructions and the exact supplied version. The published product description states a rated voltage of 220 V. A UK plug shape does not, by itself, establish the permitted operating span for every UK 230 V installation. Resolve that specification with reliable documentation before use.
Inspect the tester and the socket without opening electrical equipment. If the socket is damaged, overheating or otherwise suspect, obtain competent help and follow the appropriate procedure. A plug-in tester is not a way to make a visibly unsafe connection acceptable.
Confirm what the model checks and what each indication means. The presence of “NCV” on the pictured screen does not establish an independent specification for a non-contact function or its detection limits.
Preserve the exact indication
Record the socket's location, the tester model and the displayed result under the manufacturer's method. “CORRECT indication on this tester” is a more useful entry than an unsupported blanket statement that the installation is safe.
Simple socket indications cannot establish every aspect of protective-conductor integrity, fault-loop performance, insulation condition or protective-device operation. An earth-related problem may require measurements that a basic plug-in result does not provide. Confirm the actual capability rather than assuming the screen has checked everything behind the faceplate.

A UK plug shape and CORRECT label do not establish a complete safety verdict.
Choose the next action from the job
A landlord, inspector or electrician should keep a preliminary indication separate from the required formal assessment. The ZT-E10 does not replace an Electrical Installation Condition Report, appropriate inspection and testing, or the judgement of a competent electrician.
If a result is unexpected, leave the installation decision to the appropriate investigation. Do not open the socket or move wiring on the strength of a short label. Preserve the observation and any symptoms so the person carrying out the next test has useful context.
For ordinary record keeping, a location map helps prevent a good result at one outlet being copied to another. Repeat the identification when sockets are close together or unlabelled.
The ZT-E10's compact display format can make an eligible plug-in check easy to record. Its value comes from describing exactly what was indicated and what remains to be tested. “CORRECT” is the start of that interpretation, rather than a universal safety verdict.
For the current specification and supplied version, see the ZOYI ZT-E10 product page.