The ZOYI ZT-219 lists frequency and duty-cycle measurement alongside its voltage, current and other multimeter functions. Frequency tells you how often a repeating event occurs. Duty cycle describes the proportion of a cycle assigned to a particular state under the measurement method.
Keeping those questions separate is useful on an appropriate low-voltage pulse signal. A frequency reading can stay steady while the time spent high changes considerably.

ZOYI ZT-219 supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Begin with a known repeating signal
Choose an accessible, isolated low-voltage training or electronics circuit whose expected waveform and limits are understood. Establish the reference point and connection from the ZT-219 manual. Check the permissible frequency-input amplitude, frequency range and triggering conditions before connecting; the general function list does not supply those details.
A simple illustrative pulse train might repeat every 1ms. Its frequency would be 1kHz. If it is high for 0.25ms in each cycle, that high interval represents 25% duty cycle. A second pulse train could have the same 1kHz repetition rate and a 75% high interval. These are mathematical examples, not ZT-219 test results.
Give each displayed value a condition
Record the signal point, reference, mode, unit and the circuit's operating setting. Follow the exact-model control sequence for switching between Hz and percentage, and check the screen after each change. A note that says “25” has lost the difference between 25Hz and 25%.
If the displayed value jumps, investigate the signal and connection before averaging numbers. A poor contact, an unsuitable signal amplitude or a waveform that fails the instrument's triggering conditions can interfere with a useful result. The meter's update speed and frequency-measurement conditions also limit what the display can describe.

Illustrative pulse arithmetic; not ZT-219 measurements.
Know when the waveform is the next question
A frequency number does not reveal every pulse's shape. An occasional glitch, slow edge or unexpected level may require an appropriately specified oscilloscope and probing arrangement. True RMS on the ZT-219 is a separate capability; it does not make a numerical frequency reading a full picture of a pulse waveform.
For learning how to use a multimeter on a new function, a known signal is more useful than an unknown fault. Establish what the display means before interpreting a real circuit. Retain both the expected signal and the observed result so that another person can follow the reasoning.
The ZT-219's 19999-count display and Hz% control belong in the equipment record. The conclusion should belong to the signal: what repeats, at what rate, with what measured duty and under which conditions.
For the current specification and supplied version, see the ZOYI ZT-219 product page.