The WD-D6 digital angle finder lists dual laser lines, magnets on four sides, a 4 × 90° measuring arrangement and ±0.2° accuracy. The laser lines and the angle reading help with different parts of a setup. A visible line does not establish that the instrument's reference surface is the one you intended.
Start with the physical contact and reference, then decide what the projected line should help you align.

WD-D6 supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Choose the plane you are comparing
For a workshop setup, identify the reference surface and the second surface whose orientation matters. Check that the instrument sits fully on an appropriate clean face, with no chip, burr, paint lump or cable holding it at an angle. Magnets help retain the body on suitable material; they do not remove debris beneath it.
Use the exact WD-D6 instructions for absolute and relative operation, zeroing and display orientation. Write down which reference was used. A relative reading can be perfectly consistent with its selected baseline while answering a different question from a gravity-referenced angle.

Supplier laser-function illustration; observe the exact laser precautions.
Use the laser as a separate alignment aid
Decide which line is being used, the intended receiving surface and the geometry of the job. Confirm the relationship between the laser and measuring faces from the manual rather than assuming a projected line is calibrated to every side of the body.
Keep the beam away from eyes and reflective paths. On tools such as saws, isolate the tool and follow its setup procedure before placing measuring equipment near the blade or mechanism. Remove the gauge and other setup items before returning the machine to operation.

Projected lines do not independently validate the selected angle reference.
Re-seat before accepting a small adjustment
Lift and re-seat the instrument on the same clean position, following the relevant instructions. If the displayed result changes appreciably, investigate contact and reference selection before adjusting the work. Repeating a reading without moving anything does not check whether the instrument was sitting properly in the first place.
A simple same-plane example illustrates relative angle: if one surface is at 2° and another at 7° against the same reference, the difference is 5°. These are illustrative values, not WD-D6 test results. More complicated three-dimensional arrangements cannot always be reduced to subtracting two displayed numbers.
Keep the reference face, contact position and line purpose in your setup photograph. The useful result is not merely a bright laser line or a small angle on the display. It is an arrangement whose measured orientation and projected alignment are both understood, and which can be rebuilt when the job is checked again.
For the current specification and supplied version, see the WD-D6 product page.
For the related product overview, see the WD-D6 Angle Finder Learn More page.