The Smart Sensor ST9700 is a handheld carbon monoxide detector displaying CO in ppm and ambient temperature. Carbon monoxide and carbon dioxide are different gases. A CO reading cannot stand in for a CO2 ventilation observation, and a CO2 monitor cannot establish that carbon monoxide is absent.
Keep the gas identity prominent when choosing the instrument and recording its result.

Smart Sensor ST9700 supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Match the detector to the question
CO monitoring can form part of an appropriate combustion or occupational assessment. CO2 monitoring is often used for a different question involving occupancy and ventilation. Similar abbreviations and similar-looking handheld bodies do not make those jobs interchangeable.
The saved ST9700 listing confirms CO concentration in ppm and temperature. It does not provide the complete range, accuracy, response time, sensor-life, alarm standard or certification. Obtain the exact documentation required for the application rather than transferring a specification from a neighbouring Smart Sensor model.
A handheld reading is not a fixed alarm installation
If you are choosing a gas detector for home, establish the applicable requirements for a suitable domestic CO alarm and its installation. The existence of a handheld CO display does not prove compliance with those requirements or replace a correctly installed alarm.
Likewise, a spot check should not be used to declare a combustion appliance or room safe on its own. Use a competent assessment and the required equipment and procedure. If an alarm or suspected exposure occurs, follow the relevant emergency advice; do not remain in the area to collect more comparison readings.

A handheld CO display does not replace an approved fixed alarm.
Preserve the test and service context
For legitimate measurement work, record the instrument identity, service and calibration status, required response checks, location, time and process conditions. Follow the ST9700 instructions for sampling, warm-up, permitted environment and alarm handling.
Gas-detection discussions distinguish a “bump test” from calibration. Use the manufacturer's prescribed procedure and suitable test equipment for the actual model. A screen turning on or a temperature reading looking plausible does not independently verify the CO sensor.
Keep “CO ppm” written beside the result even when the rest of the job sheet makes the purpose seem obvious. That small habit protects the record when photographs are forwarded, instruments are swapped or a later reader sees the figure without its original context.
The ST9700 has a specific gas-measurement role. Giving that role a clear name prevents it becoming an all-purpose reassurance device simply because the word “gas” appears in the product description.
For the current specification and supplied version, see the Smart Sensor ST9700 product page.