The first power-up of a low-voltage prototype should answer a modest question: does the circuit behave as expected under a deliberately limited supply? The IPS3608 lists adjustable output from 0–36 V and 0–8 A, with an AC 100–240 V input.
Plan the voltage, current limit and observation before enabling the output. A programmable supply does not make an unknown circuit ready for full power.

IPS3608 supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Prepare the supply and the prototype separately
Use the correct mains connection for the supplied version and installation. The listing offers EU and US plug variants; do not assume a UK lead is included. Confirm the input connection, protective arrangements and manual before use.
With the output disabled and the circuit disconnected as instructed, inspect the prototype for reversed polarity, unintended connections and components with incompatible ratings. Check the output leads and connector polarity as a complete path to the board.
Choose the intended starting voltage and a current limit appropriate to the design and first test. The limit must come from knowledge of the circuit and its tolerable conditions, not a universal number copied from another project. This guide concerns suitable low-voltage prototypes, not an unknown battery-charging application.

Supplier preset-interface illustration; verify actual programming behaviour.
Make the first observation deliberate
Follow the IPS3608 instructions for setting and verifying the output before connection. Enable the prepared load only when the working arrangement is suitable, then observe voltage, current and the board's expected initial behaviour.
If current rises unexpectedly or the supply enters a limiting condition, disable the output and investigate. Do not repeatedly increase the current limit to force the prototype to start. A current limit can reduce some consequences, but it does not guarantee protection of every semiconductor or circuit path.

0–36 V and 0–8 A are separate endpoints; simultaneous full power is not inferred.
Record the condition that produced the result
Keep the board revision, load connections, voltage setting, limit and observed values together. Include any required startup or inrush behaviour from the design so that normal transient demand is not confused with an unexplained fault.
The phrase “current limit” is common in bench-supply discussions because it is part of the test method. It is not a substitute for understanding stored energy, reverse current or the supply's particular protection behaviour.
The separate 36 V and 8 A range endpoints should not be multiplied into an assumed continuous simultaneous power guarantee. Confirm the actual output-power envelope, operating conditions and programming behaviour for the version in use.
Once the first stage behaves as expected, advance under the prototype's test plan and retain the earlier observations. The IPS3608 is useful when its settings make each power-up a defined experiment, with a clear stopping condition and enough context to repeat the result.
For the current specification and supplied version, see the IPS3608 product page.
For the related product overview, see the IPS3608 DC Power Supply Learn More page.