The HoldPeak HP-6688G is listed as a 40000-count True RMS multimeter. True RMS is useful when an AC waveform is not a simple sine wave, but the label does not mean every frequency, pulse shape or amplitude can be measured accurately.
If an AC reading looks surprising on an electronics bench, first establish what waveform the instrument is being asked to measure. More display counts cannot compensate for using a meter outside its documented AC conditions.

RMS describes an effective value
Root mean square expresses an effective value associated with the waveform. For a resistive load, it connects to the heating effect. A True RMS instrument calculates or measures that quantity within its design limits, rather than relying solely on a sine-wave conversion from an average measurement.
Those design limits still matter. Relevant specifications can include frequency range, input level, crest factor and whether a function measures AC alone or AC plus DC. The HP-6688G listing does not provide a complete table for these conditions, so they should be confirmed before choosing it for a demanding waveform task.
Ask what kind of signal is present
A low-frequency sine wave, a narrow pulse train and switching ripple can have very different peak-to-RMS relationships and frequency content. Two signals can have the same RMS value while looking very different on an oscilloscope.
The phrase signal integrity is often used around the quality and behaviour of waveforms. A multimeter's RMS number is one observation within that wider problem. It does not show overshoot, ringing, pulse timing or short glitches.
For a circuit that operates at safe low voltage, an appropriate oscilloscope can help establish what the waveform actually looks like. Its probe ratings, grounding arrangement and bandwidth must also suit the task. A handheld meter should not be treated as an oscilloscope because both display voltage.

Keep counts and uncertainty separate
The 40000-count display describes capacity to show increments within the meter's implemented ranges. It does not specify AC accuracy or guarantee that the last digit represents a meaningful difference on every signal.
For example, if a waveform falls outside the specified frequency range, a stable and detailed readout may still be unsuitable for the intended decision. Stability is useful evidence about repeatability; it is not proof of correctness.
The same distinction applies to a fluctuating reading. The cause might be the source, the connection or an unsuitable measurement function. Do not automatically blame the meter or average the values by eye until they seem plausible.
Prepare the specification question before purchase
Describe the expected waveform, frequency, amplitude and required uncertainty. Ask for the HP-6688G range and conditions that cover them. The listed 1000 V AC maximum does not establish a particular safety category or permission to work on a high-energy circuit.
Keep the model identity explicit. The HP-6688G is separate from the HP-770D; features, interfaces or accuracy tables from the latter should not be copied across because both advertise 40000 counts.
Make the result useful
A useful bench note identifies the source, function, range, waveform context and operating state. If the waveform conditions are unknown, preserve that limitation and identify the next measurement needed.
The HP-6688G's True RMS specification is a reason to investigate its suitability for an AC task. The final decision depends on the complete operating conditions, not the label alone.

See the HoldPeak HP-6688G product page for the current version and kit, or read the HoldPeak HP-6688G overview before choosing.