The BENETECH GM1360 displays temperature and relative humidity for indoor climate spot checks. It is the GM1360 model, not the GM1360A. The published product description does not establish USB logging, so build a time record explicitly rather than assuming the instrument is recording between visits.
A useful manual record can still answer a well-defined question, such as how conditions differ before and after a room is occupied.

BENETECH GM1360 supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.
Give each visit a purpose
Choose a representative position and record its height, nearby surfaces and exposure to doors, sunlight, heaters or ventilation. Keep the position consistent between visits. Avoid holding the sensing area where your hand or breath is influencing it, and allow the response time required by the manual.
Record temperature and RH together. Relative humidity changes with temperature, so a higher percentage does not necessarily mean that water vapour has been added. Comparing the RH figures alone can make an ordinary temperature change look like a moisture event.
Put the time gap on the page
Write the observation time, room state and relevant events: occupancy, windows, heating, laundry or a dehumidifier. A reading at 09:00 and another at 17:00 are two observations. They do not establish the maximum, minimum or pattern during the eight hours between them.
If the purpose requires an overnight trace, unattended peaks or short events, use a suitable logger and verify its recording method. Do not present a neat line joining manual spot checks as if the GM1360 had measured every point along that line.

GM1360 spot checks do not establish an overnight trace.
Make comparisons with the same method
If another hygrometer is available, compare it under appropriate shared conditions, allowing both instruments to respond. A difference may require checking specifications, calibration and placement. It does not establish that whichever reading you prefer is correct.
The GM1360's brief product text does not give a full numerical range or accuracy statement. Confirm the exact-model specification before using a small difference or boundary value to make an important decision. Keep room observations separate from diagnosing hidden building moisture or declaring a particular treatment necessary.
Finish with a table that shows the gaps honestly: time, location, temperature, RH and event note. A small number of well-labelled spot checks can reveal a useful question for a longer study. The GM1360 helps you gather those observations; the notebook explains when they were made and what remains unknown between them.
For the current specification and supplied version, see the BENETECH GM1360 product page.
For the related product overview, see the BENETECH GM1360 Learn More page.