The FNIRSI ERD-10 displays electric field, magnetic field, radio-frequency power density and temperature. That combination can help organise observations around a desk or equipment area, provided each quantity stays attached to its own unit and measurement method.
The useful goal is a repeatable field map. It is not a single “radiation score”, a health diagnosis or a Geiger-counter survey.

Start with three different measurement columns
The listing gives EF in V/m, MF in µT or mG, and RF in mW/m². Those units describe different quantities and cannot be compared simply by choosing the largest number.
| Display | Listed span | Keep in mind |
|---|---|---|
| EF | 1–1999 V/m | Electric-field observation |
| MF | 0.01–99 µT / 0.1–1999 mG | Magnetic-field observation; check the active unit and documented range |
| RF | 0.1–999.9 mW/m² | RF power-density indication within the specified frequency response |
The two listed MF spans should not be treated as exactly interchangeable endpoints without checking the manual. Unit conversion alone does not resolve a difference in published range limits.
Define positions and device states
Sketch a few observation positions around the equipment, recording distance and orientation. Keep the meter in the same arrangement when repeating a point. Changes in position can matter, so “next to the computer” is not a repeatable location.
Where it is safe and normal to do so, compare the equipment's ordinary operating states. For example, note whether a device is off, idle or performing its usual task. Do not open appliances, touch exposed conductors or modify a supply to create a demonstration.

Change one factor at a time
If the readings jump around, first check whether position, orientation or operating state changed. A difference after moving the meter and switching the device on cannot be assigned confidently to either action. Keep the position fixed while comparing operating states, or keep the state fixed while comparing distance. Preserve both observations instead of selecting only the more dramatic value.
Nearby equipment and environmental sources can also contribute. A single reading cannot necessarily identify which device produced it. Treat the map as a way to structure further investigation, not as automatic source attribution.
Use the curve as context
The ERD-10 listing shows a Curve Record display and white/black display modes. A visible curve can help relate changes to the observation sequence. It does not establish a particular export format, sampling rate or external data-logging interface.
If a record needs to be shared, first check what the actual unit can retain and how the time or sequence is represented. A screen photograph should include the active mode and unit. A curve without those labels is difficult to interpret later.
Keep the interpretation within the instrument's scope
An alarm or coloured display is based on the device's settings and design. It is not an individual health assessment or proof that a location is compliant with an exposure standard. Formal assessment needs an appropriate frequency response, calibrated method and qualified interpretation.
The ERD-10 is also distinct from an ionising-radiation detector such as a Geiger counter. It does not establish gamma dose or identify radioactive material. The word radiation covers different phenomena; the measured quantity is what determines the tool's role.
A useful ERD-10 map therefore contains separate EF, MF and RF observations, exact positions and operating states. That makes later comparisons more meaningful without turning unrelated readings into one unsupported conclusion.

See the FNIRSI ERD-10 product page for the current version and kit, or read the FNIRSI ERD-10 overview before choosing.