Sur le FNIRSI DST-210, gammes du multimètre et limites des sondes d’oscilloscope dépendent du mode. Vérifiez atténuation, limites Vpp et déclenchement avant de quitter le multimètre.

Par EkoDeluxe · Publié le · Mis à jour le

The FNIRSI DST-210 puts a 19,999-count True RMS multimeter, a 10 MHz oscilloscope and a signal generator in one handheld body. That convenience is useful only if you treat each mode as its own instrument. A voltage figure that is acceptable in meter mode does not automatically clear the scope input or probe path.

Before you move from a numeric reading to a waveform, confirm the mode, the probe setting and the documented input limit for that path.

Start with the meter when a number is enough

Use the multimeter functions for AC/DC voltage and current, resistance, capacitance, frequency, diode and continuity within the published ranges. The 2.8-inch TFT makes the count and units easy to read; still match the lead sockets and function to the task.

A stable meter reading answers “what value is present now?” It does not show edge timing, ringing or a short glitch. If those matter, plan a separate scope observation rather than staring harder at the digits.

Keep charging off the measurement. The listed 3000 mAh pack charges over USB-C at the manufacturer’s 5 V / 1 A guidance — recharge, disconnect, then measure.

Switch to scope only after the probe path is set

  1. Identify the signal class: suitable low-voltage circuit versus a path that may exceed the scope input.
  2. Set the P6100 (or equivalent) probe to 1:1 or 10:1 as required, and enter the same attenuation in the scope UI if the instrument asks for it.
  3. Respect the mode-specific maxima in the product data: for example 80 Vpp at 1:1 and 800 Vpp at 10:1 on the listed scope path — these are not the same statement as the multimeter’s AC/DC voltage ranges.
  4. Pick a trigger mode that matches the event: Auto for a recurring waveform you are exploring, Normal when you need a defined trigger condition, Single for a one-shot capture within the instrument’s limits.
  5. Start with a conservative volts/division and timebase (within 10 mV–10 V/div and 50 ns–20 s as listed), then refine once the waveform is on screen safely.

If the display clips, rethink attenuation and the actual amplitude before raising sensitivity. Do not “borrow” the multimeter’s higher voltage headline to justify a scope connection.

Keep generator work on a suitable load

The built-in generator lists 13 waveform types with adjustable frequency, amplitude and duty cycle where supported (0–50 kHz and about 0.1–3.0 V amplitude on the published sheet). Use it to explore a suitable low-voltage response — not to drive an unknown power circuit.

When you compare generator output with a scope trace, keep ground references and amplitude expectations consistent. A mismatch here is often a setup error, not a failed DUT.

Choose a meter-only tool when waveform is out of scope

If your day is numeric checks, recording a reading over time, or threshold alerts on a meter value, a dedicated colour multimeter such as the FNIRSI DMT-99 may be the shorter path. The DST-210 earns its place when you repeatedly need reading + shape + a small test signal inside the stated 10 MHz / 48 MSa/s envelope.

It does not automatically replace every benchtop scope. Match channel count, bandwidth and capture needs to the job before treating any handheld combination unit as a substitute.

Product context: FNIRSI DST-210 overview and the buying page. Follow the supplied manual for input limits, probes and category ratings; this guide does not replace those instructions.