FNIRSI DSO-PRO : reconnaître une forme d’onde qui change avec la base de temps

Le FNIRSI DSO-PRO est un oscilloscope de poche à une voie, annonçant 5MHz de bande passante et 20MSps d’échantillonnage. Lors de l’apprentissage, surveillez une trace qui change fortement avec la base de temps. Le sig...

Par EkoDeluxe · Publié le · Mis à jour le

FNIRSI DSO-PRO product view

The FNIRSI DSO-PRO is a single-channel pocket oscilloscope with listed 5MHz bandwidth and 20MSps sampling. When learning with it, pay attention to a trace that changes dramatically as you change the timebase. The signal may have changed, but the acquisition and display can also change what you see.

The most useful starting point is an appropriate isolated low-voltage source with a known, repeating waveform. It gives you a reference while you learn the controls.

FNIRSI DSO-PRO product view

FNIRSI DSO-PRO supplier product image. Screen values and accessory layouts are illustrative; confirm the selected version.

Keep time and samples together

At a sampling rate of 20 million samples per second, the nominal interval between samples is 50ns. That is arithmetic for the headline rate, not a claim that the DSO-PRO uses that rate at every timebase or acquisition setting.

A 1kHz waveform has a 1ms period. At the headline rate, that period would contain 20,000 samples. A 5MHz waveform has a 200ns period, corresponding to only four samples at that rate. These illustrative counts explain why a bandwidth number alone does not promise detailed waveform reconstruction at that frequency.

Make one deliberate timebase change

Start with a stable view showing several cycles. Record the source setting, probe arrangement, scales and trigger. Adjust the timebase deliberately and inspect whether the displayed period, shape and stability remain plausible. Use the manual to understand any displayed sample-rate or acquisition information.

An apparent slow wave can be a sampling artefact when a faster signal is inadequately represented. Trigger behaviour, display processing and the source itself can also affect the view. Do not diagnose aliasing solely because a trace looks strange; compare with a known source and an appropriately specified reference method if the result matters.

Check a waveform at more than one timebase. TRACE: Record the apparent repetition. ACQUISITION: Keep actual sampling settings. RECHECK: Change timebase and inspect again

A changing display can be an acquisition question before a circuit fault.

Use AUTO as a starting arrangement

The listed one-key AUTO function can help establish an initial display. Check the resulting settings before interpreting the trace. A convenient automatic view does not choose the right experiment, establish safe input conditions or prove the absence of a short glitch between captured events.

Check probe attenuation, input limits and the reference connection from the exact-model instructions. Handheld power does not establish that an input can float safely on an arbitrary circuit. Keep introductory experiments on suitable isolated low-voltage systems.

When comparing oscilloscope price and portability, include the signals you actually need to observe. The DSO-PRO's compact format fits many learning and low-frequency tasks; the record should still show how the trace was acquired. A waveform accompanied by its timebase and source conditions teaches more than an attractive screenshot on its own.

For the current specification and supplied version, see the FNIRSI DSO-PRO product page.

For the related product overview, see the FNIRSI DSO-PRO Learn More page.