An intermittent fault rarely arrives on cue. The FNIRSI 1013D listing describes a two-channel, 100 MHz tablet oscilloscope with a 1 GSa/s rate, trigger modes and one-key screenshot storage. Its value in this job is the disciplined capture around the fault: what changed, when it changed and what the trigger was watching.

1013D Tablet Oscilloscope — supplier product view.

Manufacturer application artwork; it illustrates a possible waveform setup and is not an EkoDeluxe test.
Turn a complaint into a trigger question
A Reddit oscilloscope discussion recommends ‘single sweep triggering’ for a one-off event and describes a trigger level just below the steady-state voltage. That is community vocabulary, not a guarantee that every fault fits one setting. Define the event first: a missing edge, a supply dip, a reset pulse or a burst of noise. Choose the channel and coupling that expose that event.

Manufacturer application artwork; it illustrates a possible setup and is not an EkoDeluxe test.
Create a baseline before chasing the glitch
With the circuit in its known-good state, record timebase, volts/div, probe attenuation, coupling, trigger source, edge and level. The 1013D store data lists single, normal and auto trigger modes, two channels and screenshot/waveform storage. Save a clean baseline before changing the setup. Otherwise a later ‘improvement’ may only be a changed timebase.

Original workflow diagram: the record keeps setup, observation and boundary together.
Capture and annotate
Use normal or single mode when the event is rare, then save the waveform with a short note about the stimulus. If the event depends on a switch, cable movement or temperature, repeat the same action. Two channels can show a cause and response together, but only if their grounds and connection points are appropriate for the circuit. The listing does not establish input isolation, so do not infer it.
What the screenshot can and cannot prove
A captured trace can show timing and shape at the connected point. It cannot by itself identify a failed component, prove a measurement is safe at mains potential or replace the circuit’s service procedure. The manufacturer description mentions high-voltage protection and test ranges, while the store page is the governing source for this supplied version; confirm the exact probe and limit before connecting.
Keep a record someone else can use
For an intermittent capture, write a short trigger recipe someone else can repeat: stimulus, expected edge, trigger source, slope, level, timebase and save name. Keep the original clean trace beside the fault trace. If the fault disappears after probing, record that too; probe contact can be part of the circuit behaviour.
A practical handover
Write down the exact model, the setup, the observation and the limit that still needs checking. For current version and buying information, use the 1013D Tablet Oscilloscope product page.
For the related product overview, see the 1013D Tablet Oscilloscope Learn More page.