{"title":"EkoDeluxe AC\/DC \u0026 True RMS Clamp Meters","description":"\u003cp\u003eThis collection is the \u003cstrong\u003eAC\/DC clamp meter\u003c\/strong\u003e angle for UK electricians and plant engineers: when AC-only jaws are not enough, how True RMS still applies, and how to pick between a dedicated AC clamp and a meter that also handles DC current paths. Pair it with the main \u003ca href=\"\/collections\/clamp-meters\"\u003eclamp meters\u003c\/a\u003e hub for True RMS \/ inrush overview.\u003c\/p\u003e\n\n\u003ch2\u003eAC-only vs AC\/DC: which job are you on?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eScenario\u003c\/th\u003e\n\u003cth\u003eTypical need\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRing finals, lighting, most distribution AC loads\u003c\/td\u003e\n\u003ctd\u003eAC clamp (True RMS preferred)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV strings, battery systems, DC motor drives, vehicle \/ UPS DC legs\u003c\/td\u003e\n\u003ctd\u003eAC\/DC capable clamp or adapter path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor start on AC plant\u003c\/td\u003e\n\u003ctd\u003eAC True RMS + inrush \/ peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMixed van work, uncertain next call\u003c\/td\u003e\n\u003ctd\u003eReview both this page and the main clamp hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAlways confirm the individual product page for AC versus DC current ranges before you buy—category copy does not override the listing specs.\u003c\/p\u003e\n\n\u003ch2\u003eSelection checklist (AC\/DC focus)\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm DC current is required\u003c\/strong\u003e — many UK electrical jobs never leave AC; do not pay for DC jaws you will not use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS on AC\u003c\/strong\u003e — still the right default for electronic loads even when the meter also does DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange \u0026amp; resolution\u003c\/strong\u003e — DC work often needs both low-amp resolution and a high enough ceiling for the conductor you clamp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw \u0026amp; access\u003c\/strong\u003e — DC battery and PV work can be cramped; jaw shape matters as much as headline amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdapter vs integrated\u003c\/strong\u003e — some workflows use a clamp adapter with an existing meter (see HoldPeak HP-605A) instead of a full AC\/DC clamp body.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eLive models to compare\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/zoyi-zt-qs9-true-rms-clamp-meter-with-inrush-peak-hold-6000-counts\"\u003eZOYI ZT-QS9\u003c\/a\u003e — True RMS clamp with inrush \/ peak hold.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fnirsi-dmc-100-digital-clamp-meter\"\u003eFNIRSI DMC-100\u003c\/a\u003e — digital clamp meter for UK buyers comparing feature sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/tasi-ta811b-t-rms-ac-clamp-meter\"\u003eTASI TA811B\u003c\/a\u003e — True RMS AC clamp reference point.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/tasi-ta8315d-ac-clamp-multimeter-digital-clamp-meter\"\u003eTASI TA8315D\u003c\/a\u003e — AC clamp multimeter for voltage + current on one tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/holdpeak-hp-6205-digital-clamp-meter\"\u003eHoldPeak HP-6205\u003c\/a\u003e — digital clamp option in the same category family.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/holdpeak-hp-605a-clamp-adapter-600a\"\u003eHoldPeak HP-605A clamp adapter\u003c\/a\u003e — adapter route when your workflow is meter + jaw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOpen each product page for the exact AC\/DC capability, ranges, and accessories included.\u003c\/p\u003e\n\n\u003ch2\u003eRelated reading \u0026amp; collections\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/clamp-meters\"\u003eClamp meters (True RMS \u0026amp; inrush hub)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/electrical-network-testers\"\u003eElectrical network testers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/insulation-testers\"\u003eInsulation testers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/multimeter-vs-clamp-meter\"\u003eMultimeter vs clamp meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/calibration-and-accuracy-basics\"\u003eCalibration and accuracy basics\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSafety \u0026amp; UK buyer notes\u003c\/h2\u003e\n\u003cp\u003eMatch CAT rating and probe leads to the circuit. DC systems (PV, batteries) have their own arc and polarity hazards—follow manufacturer and employer rules. EkoDeluxe shows VAT-inclusive prices where applicable, offers VAT invoices, free UK delivery on qualifying orders, and typical 1–2 day dispatch with 5–7 day delivery.\u003c\/p\u003e\n\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat does AC\/DC mean on a clamp meter?\u003c\/h3\u003e\n\u003cp\u003eIt means the instrument (or adapter system) can measure alternating current and direct current through the jaw or listed DC path—not only AC mains current.\u003c\/p\u003e\n\u003ch3\u003eDo all clamp meters measure DC current?\u003c\/h3\u003e\n\u003cp\u003eNo. Many affordable clamps are AC-only. If you need DC amps, verify that on the product page before checkout.\u003c\/p\u003e\n\u003ch3\u003eIs True RMS only for AC?\u003c\/h3\u003e\n\u003cp\u003eTrue RMS describes how AC waveforms are calculated. DC current is a steady value; you still want True RMS for the AC side of an AC\/DC meter.\u003c\/p\u003e\n\u003ch3\u003eWhen should I choose a clamp adapter instead?\u003c\/h3\u003e\n\u003cp\u003eWhen you already trust a multimeter and want a jaw accessory for high current—see the HoldPeak HP-605A listing and confirm compatibility.\u003c\/p\u003e\n\u003ch3\u003eHow does this page differ from the main clamp collection?\u003c\/h3\u003e\n\u003cp\u003eThe main \u003ca href=\"\/collections\/clamp-meters\"\u003eclamp meters\u003c\/a\u003e hub leads on True RMS and inrush for general UK electrical work. This page stresses AC versus DC job fit.\u003c\/p\u003e\n\u003ch3\u003eWhere next if I need insulation tests?\u003c\/h3\u003e\n\u003cp\u003eCurrent clamps do not replace megger-style tests—use \u003ca href=\"\/collections\/insulation-testers\"\u003einsulation testers\u003c\/a\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does AC\/DC mean on a clamp meter?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It means the instrument or adapter system can measure alternating current and direct current through the jaw or listed DC path—not only AC mains current.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do all clamp meters measure DC current?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Many affordable clamps are AC-only. If you need DC amps, verify that on the product page before checkout.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is True RMS only for AC?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"True RMS describes how AC waveforms are calculated. You still want True RMS for the AC side of an AC\/DC meter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"When should I choose a clamp adapter instead?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"When you already trust a multimeter and want a jaw accessory for high current—confirm compatibility on the HoldPeak HP-605A listing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does this page differ from the main clamp collection?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The main clamp meters hub leads on True RMS and inrush. This page stresses AC versus DC job fit.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Where next if I need insulation tests?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Current clamps do not replace megger-style tests—use the insulation testers collection at \/collections\/insulation-testers.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","products":[{"product_id":"fnirsi-dmc-100-digital-clamp-meter","title":"FNIRSI DMC-100 Digital Clamp Meter","description":"\u003cp\u003eThe FNIRSI DMC-100 is a handheld digital clamp meter for electricians, installers and DIY electrical work. Listing specs state DC voltage measurement up to 1000 V.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DMC-100\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Handheld digital clamp meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC voltage:\u003c\/strong\u003e Up to 1000 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage size:\u003c\/strong\u003e 22 × 10 × 5 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage weight:\u003c\/strong\u003e 420 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat DC voltage can the DMC-100 measure?\u003c\/h4\u003e\n\u003cp\u003eIt measures DC voltage up to 1000 V (from 1688 listing specs).\u003c\/p\u003e\n\u003ch4\u003eWho is the DMC-100 for?\u003c\/h4\u003e\n\u003cp\u003eElectricians, installers, maintenance staff and DIY users who need a portable clamp meter.\u003c\/p\u003e\n\u003ch4\u003eWhat is the package size and weight?\u003c\/h4\u003e\n\u003cp\u003ePackage size is listed as 22 × 10 × 5 cm and package weight 420 g.\u003c\/p\u003e\n\u003ch4\u003eIs it a FNIRSI clamp meter?\u003c\/h4\u003e\n\u003cp\u003eYes. The DMC-100 is a FNIRSI handheld digital clamp meter.\u003c\/p\u003e\n\u003ch4\u003eIs UK delivery free?\u003c\/h4\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the FNIRSI DMC-100\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-fnirsi-dmc-100\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8055134584891\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the FNIRSI DMC-100 guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/fnirsi-dmc-100-dc-current-zero-and-direction\"\u003eFNIRSI DMC-100: DC Current, Zero and Direction →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FNIRSI","offers":[{"title":"Default Title","offer_id":44661605466171,"sku":"EKO-DMC-100","price":67.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/DMC-100_en_4.jpg?v=1792676079"},{"product_id":"holdpeak-hp-6205-digital-clamp-meter","title":"HoldPeak HP-6205 Digital Clamp Meter","description":"\u003cp\u003eThe HoldPeak HP-6205 is a handheld digital clamp meter with auto-ranging and a 6000-count LCD for everyday AC current and electrical checks. The double-open jaw design is built for quick clamp-on measurements in the field.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e HP-6205\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HoldPeak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Digital clamp meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000-count LCD (supplier listing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e Auto-range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw:\u003c\/strong\u003e Double open jaw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (ship):\u003c\/strong\u003e Approx. 0.6 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\n\n\n\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the HoldPeak HP-6205\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-holdpeak-hp-6205\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8059034566715\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the HoldPeak HP-6205 guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/holdpeak-hp-6205-check-jaw-access-and-conductors\"\u003eHoldPeak HP-6205: Jaw Access and the Single-Conductor Question →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8059034566715-clamp-access-training\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: check jaw access before the measurement\u003c\/h2\u003e\n\u003cp\u003eUse the HP-6205's jaw design to assess whether a single suitable conductor can be reached and enclosed. Follow the manual's AC measurement procedure and permitted conditions for the actual test; a fit check on a disconnected harness is not a current reading.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-products50-p8059034566715-clamp-access-training-v1.webp?v=1794910488\" alt=\"HoldPeak HP-6205 clamp meter positioned around one wire of a disconnected training harness\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: HoldPeak HP-6205 clamp meter positioned around one wire of a disconnected training harness. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"HoldPeak","offers":[{"title":"Default Title","offer_id":44686940340283,"sku":"EKO-HP-6205","price":65.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/clean_en_1_f7ddc9fa-9df5-4ec1-9ca8-6f6c5ead40a7.jpg?v=1792683688"},{"product_id":"tasi-ta8315d-ac-clamp-multimeter-digital-clamp-meter","title":"TASI TA8315D True RMS AC Clamp Meter, 600A","description":"\u003cp\u003eThe TASI TA8315D is a handheld AC clamp multimeter (digital clamp meter) for AC current up to 600 A, plus AC\/DC voltage, resistance, frequency, temperature, NCV and related checks on an English UI faceplate. True RMS (T-RMS) readout. This listing is the TA8315D only—not TA8315A, TA8315B, or TA612C.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e TA8315D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e TASI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e AC clamp multimeter \/ digital clamp meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp current:\u003c\/strong\u003e AC up to 600 A~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e AC and DC voltage ranges on the rotary dial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther functions:\u003c\/strong\u003e Resistance (Ω), diode \/ continuity \/ capacitance, Hz%, temperature (TEMP), NCV, square-wave output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Digital LCD with True RMS (T-RMS) and AUTO APO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e SELECT, MAX RANGE, HOLD\/BL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e COM and VΩHz jacks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety marking (faceplate):\u003c\/strong\u003e MAX CAT IV 600V; 750V AC \/ 1000V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (ship):\u003c\/strong\u003e Approx. 0.4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\n\n\n\n\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the TASI TA8315D\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-tasi-ta8315d\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8059558297659\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the TASI TA8315D guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/tasi-ta8315d-ac-jaw-current-vs-dc-voltage\"\u003eTASI TA8315D: AC Clamp Current and DC Voltage Are Different Functions →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8059558297659-single-conductor-clamp\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: keep one conductor inside the jaw\u003c\/h2\u003e\n\u003cp\u003eClose the exact clamp around one suitable insulated conductor of a low-voltage training circuit, with the return lead outside the jaw and all equipment covered. Show access and jaw position, not a current value or a live-mains claim.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-productssunburst50-p8059558297659-single-conductor-clamp-v1.webp?v=1794924978\" alt=\"TASI TA8315D True RMS AC Clamp Meter clamp meter around one insulated conductor on a training bench\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: TASI TA8315D True RMS AC Clamp Meter clamp meter around one insulated conductor on a training bench. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"TASI","offers":[{"title":"Default Title","offer_id":44688414605371,"sku":"EKO-TA8315D","price":39.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/clean_en_1_49ad9a37-637b-4669-834a-2cd091f186d3.jpg?v=1792697284"},{"product_id":"tasi-ta811b-t-rms-ac-clamp-meter","title":"TASI TA811B T-RMS AC Clamp Meter","description":"\u003cp\u003eThe TASI TA811B is a handheld True-RMS (T-RMS) AC clamp meter for AC current up to 600 A, plus AC\/DC voltage, resistance, capacitance, frequency, temperature and NCV on an English UI. This listing is the TA811B only—not TA811A, not TA811C, and not TA8315D.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e TA811B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e TASI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e T-RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC current:\u003c\/strong\u003e 0.01 A–600 A (jaw about 32 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC voltage:\u003c\/strong\u003e 0.001 V–600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC voltage:\u003c\/strong\u003e 0.1 mV–600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 0.1 Ω–60 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e 1 nF–100 mF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 10 Hz–10 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e −20–1000 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther:\u003c\/strong\u003e NCV, continuity, diode, HOLD, MAX\/MIN, relative, flashlight\/backlight, auto-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Up to 6000 counts; True RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 3× AAA 1.5 V (not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (ship gate):\u003c\/strong\u003e Approx. 0.424 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\n\n\n\n\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the TASI TA811B\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-tasi-ta811b\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8060253601851\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the TASI TA811B guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/tasi-ta811b-compare-a-motor-s-running-current\"\u003eTASI TA811B: Compare a Motor’s Running Current →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"TASI","offers":[{"title":"Default Title","offer_id":44689815240763,"sku":"EKO-TA811B","price":35.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/clean_en_1_0ed0aa26-89d0-4f78-85fe-fd38f8facc3d.jpg?v=1792714643"},{"product_id":"holdpeak-hp-605a-clamp-adapter-600a","title":"HoldPeak HP-605A Clamp Adapter 600A","description":"\u003cp\u003eThe HoldPeak HP-605A is a \u003cstrong\u003e600A AC\/DC clamp current adapter\u003c\/strong\u003e—not a full multimeter on its own. Clamp the 45mm jaw around a conductor, then feed the \u003cstrong\u003e1mV\/1A\u003c\/strong\u003e signal into a separate multimeter via banana plugs. The English faceplate is marked \u003cstrong\u003eHoldPeak® HP-605A\u003c\/strong\u003e \/ \u003cstrong\u003e605A AC\/DC CLAMP\u003c\/strong\u003e, with POWER \/ POWER LED \/ ACA \/ DCA controls. This listing is the \u003cstrong\u003eHP-605A only\u003c\/strong\u003e—it is \u003cstrong\u003enot\u003c\/strong\u003e HP-605C (marketing bodies marked 605C), \u003cstrong\u003enot\u003c\/strong\u003e HP-990A (the store’s tweezer SMD meter), and not the store’s separate HoldPeak HP-6688G \/ HP-770D \/ HP-6205 \/ HP-866B models.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e HP-605A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HoldPeak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 600A AC\/DC clamp current adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaceplate:\u003c\/strong\u003e HoldPeak® HP-605A \/ 605A AC\/DC CLAMP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUI:\u003c\/strong\u003e English — POWER \/ POWER LED \/ ACA \/ DCA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 600A AC \/ DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJaw:\u003c\/strong\u003e 45mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 1mV\/1A via banana plugs to a multimeter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (ship gate):\u003c\/strong\u003e Approx. 0.40 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel note:\u003c\/strong\u003e HP-605A is the HoldPeak \u003cstrong\u003e600A AC\/DC clamp adapter\u003c\/strong\u003e with face marking \u003cstrong\u003e605A AC\/DC CLAMP\u003c\/strong\u003e, a \u003cstrong\u003e45mm\u003c\/strong\u003e jaw, and banana output at \u003cstrong\u003e1mV\/1A\u003c\/strong\u003e. It is \u003cstrong\u003enot\u003c\/strong\u003e a standalone digital multimeter, \u003cstrong\u003enot\u003c\/strong\u003e HP-605C, \u003cstrong\u003enot\u003c\/strong\u003e HP-990A (tweezer SMD), and \u003cstrong\u003enot\u003c\/strong\u003e HP-6688G \/ HP-770D \/ HP-6205 \/ HP-866B. Do not order this listing if you need a full DMM, a tweezer SMD meter, or a 605C-marked clamp.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat is the HP-605A?\u003c\/h4\u003e\n\u003cp\u003eIt is a HoldPeak 600A AC\/DC clamp current adapter with a 45mm jaw. It outputs 1mV\/1A through banana plugs to a separate multimeter—it is not a full multimeter by itself.\u003c\/p\u003e\n\u003ch4\u003eIs this HP-605A or HP-605C \/ HP-990A?\u003c\/h4\u003e\n\u003cp\u003eThis listing is HoldPeak HP-605A only (SKU EKO-HP-605A). It is not HP-605C (marketing bodies marked 605C) and not HP-990A (the store’s tweezer SMD meter, SKU EKO-HP-990A).\u003c\/p\u003e\n\u003ch4\u003eWhat does it measure?\u003c\/h4\u003e\n\u003cp\u003eAC and DC current up to 600A via the clamp jaw. The adapter converts current to a 1mV\/1A signal for reading on a multimeter. It is a clamp adapter—not a tweezer SMD tester and not a handheld DMM like HP-6688G.\u003c\/p\u003e\n\u003ch4\u003eWhat is the jaw size and output?\u003c\/h4\u003e\n\u003cp\u003eJaw caliber is 45mm. Output is 1mV per 1A through banana plugs that connect to a multimeter.\u003c\/p\u003e\n\u003ch4\u003eAre clean English product photos available?\u003c\/h4\u003e\n\u003cp\u003eYes. Prefer clean_en_1 as main and clean_en_2→4 as gallery (body marked HoldPeak® HP-605A \/ 605A AC\/DC CLAMP). clean_en_5\/6 carry an Ali watermark—de-watermark or place after 1→4. Marketing 605C shots, certificates, raw captures, Alibaba page shots, and HP-605C \/ HP-990A images are not used as storefront media.\u003c\/p\u003e\n\u003ch4\u003eIs UK delivery free?\u003c\/h4\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the HoldPeak HP-605A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-holdpeak-hp-605a\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8062030872635\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the HoldPeak HP-605A guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/holdpeak-hp-605a-1-mv-a-clamp-adapter-guide\"\u003eHoldPeak HP-605A: AC\/DC Clamp Adapter Output at 1 mV\/A →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HoldPeak","offers":[{"title":"Default Title","offer_id":44703817465915,"sku":"EKO-HP-605A","price":42.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/clean_en_1_af19793b-6f8e-4f71-a4f5-b2c3b1540e51.jpg?v=1792744389"},{"product_id":"zoyi-zt-qs9-true-rms-clamp-meter-with-inrush-peak-hold-6000-counts","title":"ZOYI ZT-QS9 True RMS Clamp Meter with Inrush \u0026 Peak Hold","description":"\u003cdiv class=\"eko-buy-trust\"\u003e\n\u003cp\u003e\u003cstrong\u003eShop EkoDeluxe:\u003c\/strong\u003e Price as shown (taxes as displayed at checkout). Free delivery to the UK and Europe — dispatched in 1–2 working days, delivered in 5–7 working days after dispatch. 30-day returns. VAT invoices available where applicable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOn this listing:\u003c\/strong\u003e ZOYI ZT-QS9 (also searched as ZT QS9 \/ zt-qs9) True-RMS clamp meter — 6000 counts, inrush, peak\/data hold, NCV, CAT III 600V (see features). SKU EKO-ZT-QS9.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eLooking for the ZOYI ZT-QS9 \/ ZT QS9 clamp meter?\u003c\/strong\u003e This listing is the True-RMS 6000-count model with inrush capture, peak\/data hold and NCV (CAT III 600V).\u003c\/p\u003e\n\u003cp\u003eThe ZOYI ZT-QS9 is a professional True-RMS clamp meter for electricians, HVAC engineers and technicians. It offers a 6000-count display with inrush current capture, peak hold and NCV detection for everyday electrical diagnostics.\u003c\/p\u003e\n\u003cp\u003eMeasure AC current by clamping around a conductor without breaking the circuit. The meter also covers AC\/DC voltage, resistance, continuity, diode and frequency, with a clear backlit display for dim work areas.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6000-count True-RMS\u003c\/strong\u003e readings on conventional and noisy loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC current clamp\u003c\/strong\u003e — non-intrusive checks in consumer units, plant rooms and cabinets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\/DC voltage\u003c\/strong\u003e, resistance, continuity, diode and frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush\u003c\/strong\u003e start-up surge capture for motors, pumps, compressors and HVAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak hold \/ data hold\u003c\/strong\u003e plus \u003cstrong\u003eNCV\u003c\/strong\u003e non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAT III 600V\u003c\/strong\u003e rated for typical installation work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ZT-QS9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ZOYI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000 counts, backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue RMS:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e CAT III 600V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e AC current (clamp), AC\/DC V, Ω, continuity, diode, Hz, Inrush, Peak\/Data hold, NCV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eClamp tip:\u003c\/em\u003e Clamp around one insulated conductor only. Do not use NCV alone to prove a circuit dead. Live testing only by a competent person.\u003c\/p\u003e\n\u003cp\u003eFree delivery to the UK and Europe. Dispatched in 1–2 working days, delivered in 5–7 working days. Price as shown; taxes at checkout. VAT invoices available where applicable.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\n\n\n\n\u003ch3\u003eIs delivery free?\u003c\/h3\u003e\n\u003cp\u003eFree delivery to the UK and Europe. Dispatched in 1–2 working days, delivered in 5–7 working days. Price as shown; taxes at checkout. VAT invoices available where applicable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated products:\u003c\/strong\u003e \u003ca href=\"\/products\/uni-t-ut210e-mini-clamp-meter\"\u003eUNI-T UT210E mini clamp meter\u003c\/a\u003e · \u003ca href=\"\/products\/zoyi-zt-1000r-digital-insulation-resistance-tester\"\u003eZOYI ZT-1000R insulation resistance tester\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the ZOYI ZT-QS9\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-zoyi-zt-qs9\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8071712571451\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the ZOYI ZT-QS9 guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/zoyi-zt-qs9-compare-motor-starts-with-context\"\u003eZOYI ZT-QS9: Compare Motor Starts with Context →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is ZT QS9 the same as ZT-QS9?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. ZT QS9, ZT-QS9 and ZOYI QS9 all refer to this ZOYI True-RMS clamp meter listing.\"}},{\"@type\":\"Question\",\"name\":\"Does the ZOYI ZT-QS9 measure inrush?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Inrush mode captures motor and compressor start-up surges; see features on this page.\"}},{\"@type\":\"Question\",\"name\":\"Is the ZT-QS9 True-RMS?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The ZT-QS9 is a True-RMS clamp meter for accurate readings on both linear and non-linear loads.\"}},{\"@type\":\"Question\",\"name\":\"What safety category is it?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"CAT III 600V for typical installation and distribution work.\"}},{\"@type\":\"Question\",\"name\":\"Is delivery free?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Free delivery to the UK and Europe. Dispatched in 1–2 working days, delivered in 5–7 working days.\"}}]}\u003c\/script\u003e","brand":"ZOYI","offers":[{"title":"Default Title","offer_id":44752195780667,"sku":"EKO-ZT-QS9","price":47.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/ZT-QS9_clean_1.jpg?v=1792941183"},{"product_id":"tasi-ta8315b-ac-clamp-multimeter","title":"TASI TA8315B AC Clamp Multimeter True RMS","description":"\u003cp\u003eThe TASI TA8315B is a handheld True RMS AC clamp meter for current up to 600 A. It also lists AC voltage, resistance, frequency-related checks, NCV and temperature functions on an English faceplate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e TA8315B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e TASI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e AC clamp multimeter \/ True RMS clamp meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaceplate:\u003c\/strong\u003e AC CLAMP MULTIMETER\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp current:\u003c\/strong\u003e AC up to 600 A~ (0.01–600 A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e AC V~ on the rotary dial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther functions:\u003c\/strong\u003e Hz·V, resistance (Ω), NCV, temperature (TEMP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Digital LCD with True RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e SELECT, MAX RANGE, HOLD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e COM and VΩ jacks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (ship):\u003c\/strong\u003e Approx. 0.4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel note:\u003c\/strong\u003e TA8315B is the TASI AC 600 A True-RMS clamp multimeter with English faceplate AC CLAMP MULTIMETER. It is \u003cstrong\u003enot\u003c\/strong\u003e TA8315A, \u003cstrong\u003enot\u003c\/strong\u003e TA8315C\/E, \u003cstrong\u003enot\u003c\/strong\u003e TA8315D (EKO-TA8315D), \u003cstrong\u003enot\u003c\/strong\u003e TA8321*, and \u003cstrong\u003enot\u003c\/strong\u003e TA8322*. Do not use A\/C\/D\/E or insulation-tester photos on this page.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\n\n\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What does the TA8315B measure?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"It is an AC clamp multimeter with True RMS for AC current (up to 600 A on the clamp), plus AC voltage and other common functions (Ω, NCV, TEMP, Hz·V) on the same handheld unit.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is the clamp AC only or AC\/DC current?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"The faceplate labels this unit an AC CLAMP MULTIMETER; the clamp current range on the dial is 600 A AC~. Voltage on the dial is AC V~.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is this TA8315B or TA8315A \/ TA8315D \/ TA8321*?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"This listing is TASI TA8315B only (SKU EKO-TA8315B). It is not TA8315A, not TA8315C\/E, not TA8315D (SKU EKO-TA8315D), not TA8321*, and not TA8322*.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Does it have True RMS?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes. This listing is the True-RMS TA8315B AC clamp multimeter as specified for SKU EKO-TA8315B.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Are clean English product photos available?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes. Main image is clean_en_1 (body marked TASI TA8315B; English UI); gallery clean_en_2→clean_en_5. Raw supplier stills with Chinese badges, 1688 page captures, and cross-SKU A\/C\/D\/E photos are not used as main images.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is UK delivery free?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Free UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\"\n          }\n        }\n      ]\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the TASI TA8315B\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eExplore its functions, suitable tasks and key differences before you choose. \u003ca href=\"https:\/\/ekodeluxe.co.uk\/pages\/learn-tasi-ta8315b\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"eko-model-blog-entry\" data-product-id=\"8081859084347\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eRead the TASI TA8315B guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003ca href=\"https:\/\/ekodeluxe.co.uk\/blogs\/guides\/tasi-ta8315b-why-amps-are-not-an-energy-bill\"\u003eTASI TA8315B: Why Amps Are Not an Energy Bill →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8081859084347-single-conductor-clamp\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: keep one conductor inside the jaw\u003c\/h2\u003e\n\u003cp\u003eClose the exact clamp around one suitable insulated conductor of a low-voltage training circuit, with the return lead outside the jaw and all equipment covered. Show access and jaw position, not a current value or a live-mains claim.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-productssunburst50-p8081859084347-single-conductor-clamp-v1.webp?v=1794925042\" alt=\"TASI TA8315B AC Clamp Multimeter True RMS clamp meter around one insulated conductor on a training bench\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: TASI TA8315B AC Clamp Multimeter True RMS clamp meter around one insulated conductor on a training bench. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"TASI","offers":[{"title":"Default Title","offer_id":44819254280251,"sku":"EKO-TA8315B","price":31.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/clean_en_1_908438ef-b8cb-4ec5-b020-bf8b60025ce5.jpg?v=1793359708"},{"product_id":"uni-t-ut210e-mini-clamp-meter","title":"UNI-T UT210E Mini Clamp Meter","description":"\u003cp class=\"eko-trust-strip\" style=\"font-size:13px;color:#59616c;margin:0 0 14px\"\u003ePrice as shown · Taxes at checkout · Free UK \u0026amp; Europe delivery · Dispatch in 1–2 working days · Delivered about 5–7 working days after dispatch\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT210E\u003c\/strong\u003e is a True RMS mini digital clamp meter with a \u003cstrong\u003e2000-count\u003c\/strong\u003e display and \u003cstrong\u003e100 A AC\/DC\u003c\/strong\u003e current ranges (2 A \/ 20 A \/ 100 A). Face silk: \u003cem\u003eUNI-T UT210E True RMS\u003c\/em\u003e; controls include \u003cstrong\u003eZERO\u003c\/strong\u003e, \u003cstrong\u003eSELECT \/ V.F.C\u003c\/strong\u003e and \u003cstrong\u003eHOLD \/ Backlight\u003c\/strong\u003e, plus an NCV position. Listed voltage to \u003cstrong\u003e600 V\u003c\/strong\u003e, resistance to \u003cstrong\u003e20 MΩ\u003c\/strong\u003e and capacitance to about \u003cstrong\u003e20 mF\u003c\/strong\u003e. Price as shown; free UK \u0026amp; Europe delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT210A, UT210B, UT210C or UT210D. This page is the UT210E only — do not use another UT210-series poster for ranges or accessories.\u003c\/p\u003e\n\u003ch2\u003eMini jaw True RMS clamp for AC\/DC work\u003c\/h2\u003e\n\u003cp\u003eThe UT210E suits confined conductors where a ~17 mm jaw can close fully around a single suitable lead. True RMS applies to the listed AC voltage and current paths; V.F.C is available when variable-frequency interference needs filtering on AC V\/A. Follow the manual for ZERO, orientation and category limits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC\/DC current: 2 A \/ 20 A \/ 100 A (low range resolution down to 1 mA as listed)\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage: up to 600 V\u003c\/li\u003e\n\u003cli\u003eResistance: up to 20 MΩ; capacitance: up to ~20 mF; frequency: 10 Hz–60 kHz\u003c\/li\u003e\n\u003cli\u003eTrue RMS; V.F.C for variable-frequency AC V\/A; NCV; diode; continuity\u003c\/li\u003e\n\u003cli\u003eZERO for DCA zero \/ relative on supported V\/C functions; data hold; backlight; auto power off\u003c\/li\u003e\n\u003cli\u003eJaw ~17 mm; body ~175 × 60 × 33.5 mm; weight ~170 g; power 2 × AAA\u003c\/li\u003e\n\u003cli\u003eMeasurement categories listed on UNI-T series data: CAT II 600 V \/ CAT III 300 V — confirm leads and task before use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to zero DC current before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eSelect the DC current function and the range that fits the expected current.\u003c\/li\u003e\n\u003cli\u003eWith the jaw closed and \u003cstrong\u003eempty\u003c\/strong\u003e, follow the manual’s ZERO sequence so the baseline is near zero.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eKeep jaw orientation consistent with the documented polarity convention; a sign change can be direction, not a failed load.\u003c\/li\u003e\n\u003cli\u003eUse V.F.C only when the AC V\/A path needs the listed low-pass behaviour; long-press SELECT as the manual describes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut210e-zero-dc-before-you-clamp\"\u003eUNI-T UT210E: Zero DC Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT210E\u003c\/li\u003e\n\u003cli\u003eType: True RMS mini digital clamp meter\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 2000\u003c\/li\u003e\n\u003cli\u003eAC\/DC current: 2 A \/ 20 A \/ 100 A\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage: up to 600 V\u003c\/li\u003e\n\u003cli\u003eResistance: up to 20 MΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance: up to ~20 mF\u003c\/li\u003e\n\u003cli\u003eFrequency: 10 Hz–60 kHz\u003c\/li\u003e\n\u003cli\u003eJaw opening: ~17 mm\u003c\/li\u003e\n\u003cli\u003eFunctions: True RMS, V.F.C, NCV, diode, continuity, ZERO, HOLD, backlight, auto power off\u003c\/li\u003e\n\u003cli\u003ePower: 2 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eSize \/ weight: ~175 × 60 × 33.5 mm \/ ~170 g\u003c\/li\u003e\n\u003cli\u003eCategories listed (series data): CAT II 600 V, CAT III 300 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, bag and batteries on this buying page before ordering. Follow the supplied manual for accuracy conditions, ZERO behaviour and measurement-category suitability. This is not a 1000 A clamp.\u003c\/p\u003e\n\u003cp\u003eFree delivery to the UK and Europe. Dispatched in 1–2 working days, delivered in 5–7 working days. Price as shown; taxes at checkout. VAT invoices available where applicable.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\n\n\n\n\n\n\u003ch3\u003eIs delivery free?\u003c\/h3\u003e\n\u003cp\u003eYes. Free delivery to the UK and Europe. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. Price as shown; taxes at checkout.\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT210E\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003ejaw fit, ZERO practice, V.F.C and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut210e\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What current ranges does the UT210E list?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"AC and DC current on 2 A, 20 A and 100 A ranges. Low-range resolution is listed down to 1 mA. It is not a 1000 A clamp.\"}}, {\"@type\": \"Question\", \"name\": \"Does the UNI-T UT210E measure DC current?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Use the DC current function, zero with an empty closed jaw as the manual describes, then clamp a single suitable conductor with consistent orientation.\"}}, {\"@type\": \"Question\", \"name\": \"What is V.F.C on the UT210E?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"V.F.C is UNI-T’s variable-frequency (low-pass) mode for suitable AC voltage and current measurements where high-frequency interference would otherwise disturb the reading. Enable it only when the task needs it; follow the SELECT \/ V.F.C sequence in the manual.\"}}, {\"@type\": \"Question\", \"name\": \"Is NCV proof that a circuit is safe to touch?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. NCV is a non-contact indication aid only. Use the correct safe-isolation procedure and equipment for the installation.\"}}, {\"@type\": \"Question\", \"name\": \"Is the UNI-T UT210E the same as UT210A \/ UT210D?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. UT210E is a separate True RMS model with its own 100 A AC\/DC and V.F.C listing. Do not apply UT210A–D poster specifications to this page.\"}}, {\"@type\": \"Question\", \"name\": \"What else can the UT210E measure with leads?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Listed functions include AC\/DC voltage to 600 V, resistance to 20 MΩ, capacitance to about 20 mF, frequency 10 Hz–60 kHz, diode and continuity — subject to the manual’s ranges and leads.\"}}, {\"@type\": \"Question\", \"name\": \"Is delivery free for the UNI-T UT210E?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Free delivery to the UK and Europe. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. Price as shown; taxes at checkout.\"}}]}\u003c\/script\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8085046427707-dc-single-wire\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: zero the DC clamp before the check\u003c\/h2\u003e\n\u003cp\u003eSelect the appropriate DC current function and follow the manual's ZERO procedure with the jaw closed and empty. Then enclose a single suitable conductor, keeping orientation consistent; the scene illustrates the setup and contains no measured current result.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-products50-p8085046427707-dc-single-wire-v1.webp?v=1794910568\" alt=\"UNI-T UT210E mini clamp around one insulated wire of a battery-powered demonstration loop\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: UNI-T UT210E mini clamp around one insulated wire of a battery-powered demonstration loop. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44841926131771,"sku":"EKO-UT210E","price":79.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT210E_clean_en_1.jpg?v=1793609392"},{"product_id":"uni-t-ut200a-plus-clamp-meter","title":"UNI-T UT200A+ Clamp Meter","description":"\u003cp\u003eThe UNI-T UT200A+ is a True RMS clamp meter with 3 A, 30 A and 400 A AC current ranges. It also measures AC\/DC voltage, frequency and resistance with test leads and provides diode and continuity tests. The clamp measures AC current only; DC voltage readings do not indicate a DC current range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT200B+, UT200R or UT210E. This page is the \u003cstrong\u003eUT200A+\u003c\/strong\u003e only — AC current clamp (not a DC-current clamp). Do not use A+\/B+ factory combo posters or another UT200-series photo for ranges or accessories.\u003c\/p\u003e\n\u003ch2\u003eTrue RMS 400 A AC clamp with English face controls\u003c\/h2\u003e\n\u003cp\u003eThe UT200A+ suits single-conductor AC current checks where you pick the listed range before the jaw closes. True RMS applies to the listed AC paths. Voltage on the V functions can show AUTO ranging on the English display; AC current is selected on the rotary dial at 3 A~, 30 A~ or 400 A~. Follow the manual for LIVE, HOLD, category limits and lead use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: 3 A~ \/ 30 A~ \/ 400 A~ (rotary — pick the range that fits the expected load)\u003c\/li\u003e\n\u003cli\u003eTrue RMS; face marking \u003cem\u003e400A AC CLAMP METER\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety face marking: \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLead measurements: AC\/DC voltage (listed to 600 V class on the face category), frequency (V~ \/ Hz), resistance, diode, continuity\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e3.099\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e · \u003cstrong\u003eV\u003c\/strong\u003e · \u003cstrong\u003eAUTO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eControls: rotary dial; \u003cstrong\u003eSELECT\u003c\/strong\u003e; \u003cstrong\u003eLIVE\u003c\/strong\u003e; HOLD \/ backlight\u003c\/li\u003e\n\u003cli\u003eInputs: COM and V Ω Hz jacks\u003c\/li\u003e\n\u003cli\u003ePower: 2 × AAA (shown with battery door open on the rear kit shot)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp like UT210E\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to pick the AC range before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eEstimate the expected AC current and open the jaw only when access is safe.\u003c\/li\u003e\n\u003cli\u003eTurn the dial to \u003cstrong\u003e3 A~\u003c\/strong\u003e, \u003cstrong\u003e30 A~\u003c\/strong\u003e or \u003cstrong\u003e400 A~\u003c\/strong\u003e so the range covers the load with headroom — do not start on 3 A~ if you expect tens of amps.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use HOLD if you need to step away from the conductor to note the value.\u003c\/li\u003e\n\u003cli\u003eFor voltage \/ Hz \/ resistance \/ diode \/ continuity, use the supplied leads in the documented jacks and follow the SELECT \/ LIVE sequences in the manual. LIVE is an indication aid, not proof of isolation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut200a-plus-pick-the-ac-range-before-you-clamp\"\u003eUNI-T UT200A+: Pick the AC Range Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT200A+\u003c\/li\u003e\n\u003cli\u003eType: True RMS digital clamp meter (400 A AC)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT200A+ · True RMS · 400A AC CLAMP METER · CAT III 600V\u003c\/li\u003e\n\u003cli\u003eAC current ranges: 3 A~ \/ 30 A~ \/ 400 A~\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 3.099 \/ DC \/ V \/ AUTO\u003c\/li\u003e\n\u003cli\u003eLead functions: AC\/DC voltage, frequency (V~ \/ Hz), resistance, diode, continuity\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, LIVE, HOLD \/ backlight; auto indicators as shown on the English UI\u003c\/li\u003e\n\u003cli\u003eSafety marking (face): CAT III 600 V\u003c\/li\u003e\n\u003cli\u003ePower: 2 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, batteries and the English manual on this buying page before ordering. Follow the supplied manual for accuracy conditions, LIVE behaviour and measurement-category suitability. Do not treat this page as UT200B+, UT200R or UT210E.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT200A+\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eAC range choice, True RMS, CAT III 600 V limits and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut200a-plus\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut200a-plus-pick-the-ac-range-before-you-clamp\"\u003eUNI-T UT200A+: Pick the AC Range Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849311481915,"sku":"EKO-UT200A+","price":40.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT200A_plus_clean_en_1.jpg?v=1793685752"},{"product_id":"uni-t-ut200b-plus-clamp-meter","title":"UNI-T UT200B+ Clamp Meter","description":"\u003cp\u003eThe UNI-T UT200B+ is a True RMS clamp meter with 3 A, 30 A and 600 A AC current ranges. Test-lead functions include AC\/DC voltage, frequency, resistance, capacitance, diode and continuity. Choose it for AC current clamping; this model does not provide a DC clamp-current range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT200A+, UT200R or UT210E. This page is the \u003cstrong\u003eUT200B+\u003c\/strong\u003e only — a \u003cstrong\u003e600 A AC\u003c\/strong\u003e current clamp (not the 400 A UT200A+, and not a DC-current clamp). Do not use A+\/B+ factory combo posters or another UT200-series photo for ranges or accessories.\u003c\/p\u003e\n\u003ch2\u003eTrue RMS 600 A AC clamp with English face controls\u003c\/h2\u003e\n\u003cp\u003eThe UT200B+ suits single-conductor AC current checks where you pick the listed range before the jaw closes. True RMS applies to the listed AC paths. Voltage on the V functions can show AUTO ranging on the English display; AC current is selected on the rotary dial at 3 A~, 30 A~ or 600 A~. Follow the manual for LIVE, HOLD, category limits and lead use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: 3 A~ \/ 30 A~ \/ 600 A~ (rotary — pick the range that fits the expected load)\u003c\/li\u003e\n\u003cli\u003eTrue RMS; face marking \u003cem\u003e600A AC CLAMP METER\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety face marking: \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLead measurements: AC\/DC voltage (listed to 600 V class on the face category), frequency (V~ \/ Hz), resistance, capacitance, diode, continuity\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e3.099\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e · \u003cstrong\u003eV\u003c\/strong\u003e · \u003cstrong\u003eAUTO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eControls: rotary dial; \u003cstrong\u003eSELECT\u003c\/strong\u003e; \u003cstrong\u003eLIVE\u003c\/strong\u003e; HOLD \/ backlight\u003c\/li\u003e\n\u003cli\u003eInputs: COM and V Ω Hz jacks\u003c\/li\u003e\n\u003cli\u003ePower: 2 × AAA (shown with battery door open on the rear kit shot)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp like UT210E, and \u003cstrong\u003enot\u003c\/strong\u003e the 400 A UT200A+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to pick the AC range before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eEstimate the expected AC current and open the jaw only when access is safe.\u003c\/li\u003e\n\u003cli\u003eTurn the dial to \u003cstrong\u003e3 A~\u003c\/strong\u003e, \u003cstrong\u003e30 A~\u003c\/strong\u003e or \u003cstrong\u003e600 A~\u003c\/strong\u003e so the range covers the load with headroom — do not start on 3 A~ if you expect tens or hundreds of amps.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use HOLD if you need to step away from the conductor to note the value.\u003c\/li\u003e\n\u003cli\u003eFor voltage \/ Hz \/ resistance \/ capacitance \/ diode \/ continuity, use the supplied leads in the documented jacks and follow the SELECT \/ LIVE sequences in the manual. LIVE is an indication aid, not proof of isolation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut200b-plus-pick-the-ac-range-before-you-clamp\"\u003eUNI-T UT200B+: Pick the AC Range Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT200B+\u003c\/li\u003e\n\u003cli\u003eType: True RMS digital clamp meter (600 A AC)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT200B+ · True RMS · 600A AC CLAMP METER · CAT III 600V\u003c\/li\u003e\n\u003cli\u003eAC current ranges: 3 A~ \/ 30 A~ \/ 600 A~\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 3.099 \/ DC \/ V \/ AUTO\u003c\/li\u003e\n\u003cli\u003eLead functions: AC\/DC voltage, frequency (V~ \/ Hz), resistance, capacitance, diode, continuity\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, LIVE, HOLD \/ backlight; auto indicators as shown on the English UI\u003c\/li\u003e\n\u003cli\u003eSafety marking (face): CAT III 600 V\u003c\/li\u003e\n\u003cli\u003ePower: 2 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, batteries and the English manual on this buying page before ordering. Follow the supplied manual for accuracy conditions, LIVE behaviour and measurement-category suitability. Do not treat this page as UT200A+, UT200R or UT210E.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT200B+\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003eAC range choice, True RMS, CAT III 600 V limits and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut200b-plus\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut200b-plus-pick-the-ac-range-before-you-clamp\"\u003eUNI-T UT200B+: Pick the AC Range Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849331929147,"sku":"EKO-UT200B+","price":59.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT200B_plus_clean_en_1.jpg?v=1793685988"},{"product_id":"uni-t-ut213b-clamp-meter","title":"UNI-T UT213B Clamp Meter","description":"\u003cp\u003eThe UNI-T UT213B is a True RMS 400 A AC clamp meter with a 4000-count display. Its dial also provides AC\/DC voltage, resistance, capacitance, temperature, frequency, diode and continuity functions, with HOLD, MAX\/MIN and relative measurement controls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT213A, UT213C, UT210E, UT200A+ or UT200B+. This page is the \u003cstrong\u003eUT213B\u003c\/strong\u003e only — a \u003cstrong\u003e400 A AC\u003c\/strong\u003e True RMS clamp (not a DC-current clamp, and not a factory A\/B\/C combo poster). Do not use UT213A\/UT213C co-branded images or another UT213-series photo for ranges or accessories.\u003c\/p\u003e\n\u003ch2\u003eTrue RMS 400 A AC clamp with NCV, temperature and English face controls\u003c\/h2\u003e\n\u003cp\u003eThe UT213B suits single-conductor AC current checks on the \u003cstrong\u003eA~\u003c\/strong\u003e dial position, with AUTO shown on the English display example. True RMS and 4000 counts are marked on the face. Lead and dial functions extend to voltage, ohms family, temperature, frequency\/duty and a dedicated \u003cstrong\u003eNCV\u003c\/strong\u003e position with an NCV indicator. Follow the manual for SELECT, HOLD, MAX MIN, REL, category limits and lead use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: listed \u003cstrong\u003e400 A AC\u003c\/strong\u003e on face \/ jaw silk (\u003cem\u003e400A AC Digital Clamp Meter\u003c\/em\u003e)\u003c\/li\u003e\n\u003cli\u003eTrue RMS; display \u003cstrong\u003e4000 Counts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety marking (face + jaw): \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e0.000\u003c\/strong\u003e with \u003cstrong\u003eAC\u003c\/strong\u003e · \u003cstrong\u003eA\u003c\/strong\u003e · \u003cstrong\u003eAUTO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial: OFF · A~ · V~ · V⎓ · Ω \/ diode \/ continuity \/ capacitance · capacitance · °F °C · Hz% · NCV\u003c\/li\u003e\n\u003cli\u003eFace keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e; \u003cstrong\u003eHOLD\u003c\/strong\u003e \/ backlight; \u003cstrong\u003eMAX MIN\u003c\/strong\u003e; \u003cstrong\u003eREL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSide torch \/ worklight control; NCV indicator above the dial\u003c\/li\u003e\n\u003cli\u003eInputs: COM and V Ω Hz jacks\u003c\/li\u003e\n\u003cli\u003ePower: \u003cstrong\u003e3 × 1.5 V AAA\u003c\/strong\u003e (stated on the rear battery door)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp like UT210E\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to keep NCV in proportion before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eTreat the \u003cstrong\u003eNCV\u003c\/strong\u003e dial position as a prompt to investigate — never as proof that a circuit is safe to touch or isolated.\u003c\/li\u003e\n\u003cli\u003eFor AC current, turn the dial to \u003cstrong\u003eA~\u003c\/strong\u003e, confirm safe access, then clamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value, and \u003cstrong\u003eMAX MIN\u003c\/strong\u003e \/ \u003cstrong\u003eREL\u003c\/strong\u003e only as the manual describes for the function you selected.\u003c\/li\u003e\n\u003cli\u003eFor voltage, ohms family, temperature (°F °C) or Hz%, use the supplied leads (and any documented temperature probe) in the COM \/ V Ω Hz jacks and follow SELECT sequences in the manual.\u003c\/li\u003e\n\u003cli\u003eMatch the task to the face marking \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e and the competent procedure for that installation — NCV does not replace a proving unit or safe-isolation steps.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut213b-treat-ncv-as-a-prompt-not-isolation-proof\"\u003eUNI-T UT213B: Treat NCV as a Prompt, Not Isolation Proof\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT213B\u003c\/li\u003e\n\u003cli\u003eType: True RMS digital clamp meter (400 A AC)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 4000 (face marking)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT213B · True RMS 4000 Counts · 400A AC Digital Clamp Meter · CAT III 600V\u003c\/li\u003e\n\u003cli\u003eAC current: listed 400 A AC (A~ dial; AUTO shown on English UI example)\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 0.000 \/ AC \/ A \/ AUTO\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: AC voltage (V~), DC voltage (V⎓), resistance \/ diode \/ continuity \/ capacitance, temperature (°F °C), frequency \/ duty (Hz%), NCV\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, HOLD \/ backlight, MAX MIN, REL; side torch \/ worklight\u003c\/li\u003e\n\u003cli\u003eSafety marking (face + jaw): CAT III 600 V\u003c\/li\u003e\n\u003cli\u003ePower: 3 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, batteries, temperature probe (if required for °F °C) and the English manual on this buying page before ordering. Follow the supplied manual for accuracy conditions, NCV behaviour and measurement-category suitability. Do not treat this page as UT213A, UT213C, UT210E, UT200A+ or UT200B+. Jaw opening size and numeric accuracy tolerances are not claimed here — use the manual.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT213B\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e400 A AC True RMS, 4000 counts, NCV limits, temperature dial use and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut213b\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut213b-treat-ncv-as-a-prompt-not-isolation-proof\"\u003eUNI-T UT213B: Treat NCV as a Prompt, Not Isolation Proof\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8086977052731-isolated-ac-loop\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: keep the AC clamp on one conductor\u003c\/h2\u003e\n\u003cp\u003eThe UT213B clamp is for AC current. Select the A~ function and use one suitable conductor with the jaw closed; do not enclose the complete supply-and-return cable or treat NCV as proof of safe isolation.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-products50-p8086977052731-isolated-ac-loop-v1.webp?v=1794910469\" alt=\"UNI-T UT213B AC clamp around one insulated conductor on a low-voltage training bench\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: UNI-T UT213B AC clamp around one insulated conductor on a low-voltage training bench. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849394647099,"sku":"EKO-UT213B","price":95.17,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT213B_clean_en_1.jpg?v=1793686624"},{"product_id":"uni-t-ut216a-clamp-meter","title":"UNI-T UT216A Clamp Meter","description":"\u003cp\u003eThe UNI-T UT216A is a True RMS clamp meter with 6 A, 60 A and 600 A AC current ranges and a 6000-count display. It also provides AC voltage, resistance, capacitance, diode and continuity functions, plus HOLD, MAX\/MIN and relative measurement controls.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT216B, UT216C, UT213B, UT200B+ or UT200A+. This page is the \u003cstrong\u003eUT216A\u003c\/strong\u003e only — a \u003cstrong\u003e600 A AC\u003c\/strong\u003e True RMS clamp with \u003cstrong\u003e6000 counts\u003c\/strong\u003e and discrete \u003cstrong\u003e6 \/ 60 \/ 600 A~\u003c\/strong\u003e ranges (not a DC-current clamp, and not a factory A\/B\/C combo poster). Do not use UT216B\/UT216C co-branded images or another UT216-series photo for ranges or accessories.\u003c\/p\u003e\n\n\u003ch2\u003eTrue RMS 600 A AC clamp with 6000 counts, discrete AC ranges and NCV\u003c\/h2\u003e\n\u003cp\u003eThe UT216A suits single-conductor AC current checks where you pick the listed range before the jaw closes. True RMS and 6000 counts are marked on the face. Lead and dial functions extend to AC voltage, the ohms family and a dedicated \u003cstrong\u003eNCV\u003c\/strong\u003e position. Follow the manual for SELECT, HOLD, MAX MIN, REL, category limits and lead use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: discrete rotary \u003cstrong\u003e6 A~ \/ 60 A~ \/ 600 A~\u003c\/strong\u003e (pick the range that fits the expected load)\u003c\/li\u003e\n\u003cli\u003eTrue RMS; display \u003cstrong\u003e6000 Counts\u003c\/strong\u003e (face silk)\u003c\/li\u003e\n\u003cli\u003eFace silk: \u003cem\u003e600A AC Digital Clamp Meter\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety markings (face \/ jaw \/ inputs): \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e · CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eEnglish UI examples: display \u003cstrong\u003e00.00\u003c\/strong\u003e or \u003cstrong\u003e0.000\u003c\/strong\u003e with \u003cstrong\u003eAC\u003c\/strong\u003e · \u003cstrong\u003eA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial: OFF · 6A~ · 60A~ · 600A~ · V~ · Ω \/ diode \/ continuity \/ capacitance · NCV\u003c\/li\u003e\n\u003cli\u003eFace keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e; \u003cstrong\u003eHOLD\u003c\/strong\u003e \/ backlight; \u003cstrong\u003eMAX MIN\u003c\/strong\u003e; \u003cstrong\u003eREL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInputs: COM and V Ω jacks\u003c\/li\u003e\n\u003cli\u003ePower: \u003cstrong\u003e3 × 1.5 V AAA\u003c\/strong\u003e (shown with the kit \/ soft pouch shot)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to pick the AC range before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eEstimate the expected AC current and open the jaw only when access is safe.\u003c\/li\u003e\n\u003cli\u003eTurn the dial to \u003cstrong\u003e6 A~\u003c\/strong\u003e, \u003cstrong\u003e60 A~\u003c\/strong\u003e or \u003cstrong\u003e600 A~\u003c\/strong\u003e so the range covers the load with headroom — do not start on 6 A~ if you expect tens or hundreds of amps.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value, and \u003cstrong\u003eMAX MIN\u003c\/strong\u003e \/ \u003cstrong\u003eREL\u003c\/strong\u003e only as the manual describes for the function you selected.\u003c\/li\u003e\n\u003cli\u003eFor voltage, ohms family or NCV, use the documented dial position \/ leads and follow SELECT sequences in the manual. NCV is an indication aid, not proof of isolation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut216a-pick-the-ac-range-before-you-clamp\"\u003eUNI-T UT216A: Pick the AC Range Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT216A\u003c\/li\u003e\n\u003cli\u003eType: True RMS digital clamp meter (600 A AC)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 6000 (face marking)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT216A · True RMS 6000 Counts · 600A AC Digital Clamp Meter\u003c\/li\u003e\n\u003cli\u003eAC current ranges: 6 A~ \/ 60 A~ \/ 600 A~\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English examples): 00.00 \/ AC \/ A · 0.000 \/ AC \/ A\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: AC voltage (V~), resistance \/ diode \/ continuity \/ capacitance, NCV\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, HOLD \/ backlight, MAX MIN, REL\u003c\/li\u003e\n\u003cli\u003eSafety markings (face \/ jaw \/ inputs): CAT III 600 V · CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003ePower: 3 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, batteries, soft pouch and the English manual on this buying page before ordering. Follow the supplied manual for accuracy conditions, NCV behaviour and measurement-category suitability. Do not treat this page as UT216B, UT216C, UT213B, UT200B+ or UT200A+. Jaw opening size and numeric accuracy tolerances are not claimed here — use the manual. Seller jaw millimetre claims that conflict with a full-size 600 A clamp photo are ignored.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT216A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e600 A AC True RMS, 6000 counts, discrete 6 \/ 60 \/ 600 A~ ranges, NCV limits and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut216a\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut216a-pick-the-ac-range-before-you-clamp\"\u003eUNI-T UT216A: Pick the AC Range Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849457987643,"sku":"EKO-UT216A","price":81.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT216A_clean_en_1.jpg?v=1793687626"},{"product_id":"uni-t-ut216b-clamp-meter","title":"UNI-T UT216B Clamp Meter","description":"\u003cp\u003eThe UNI-T UT216B is a True RMS AC clamp meter with 60 A and 600 A current ranges and a 6000-count display. Its controls include V.F.C., HOLD, MAX\/MIN and relative measurement. Lead functions cover voltage, frequency, resistance, capacitance, diode and continuity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT216A, UT216C, UT213B, UT200B+ or UT200A+. This page is the \u003cstrong\u003eUT216B\u003c\/strong\u003e only — a \u003cstrong\u003e600 A AC\u003c\/strong\u003e True RMS clamp with \u003cstrong\u003e6000 counts\u003c\/strong\u003e, discrete \u003cstrong\u003e60 \/ 600 A~\u003c\/strong\u003e ranges and face \u003cstrong\u003eSELECT \/ V.F.C.\u003c\/strong\u003e (not the UT216A 6 \/ 60 \/ 600 set, and not a factory A\/B\/C combo poster). Do not use UT216A\/UT216C co-branded images or another UT216-series photo for ranges or accessories.\u003c\/p\u003e\n\n\u003ch2\u003eTrue RMS 600 A AC clamp with 6000 counts, 60 \/ 600 A~ ranges and SELECT \/ V.F.C.\u003c\/h2\u003e\n\u003cp\u003eThe UT216B suits single-conductor AC current checks where you pick the listed range before the jaw closes. True RMS and 6000 counts are marked on the face. Lead and dial functions extend to voltage, frequency, the ohms family and a dedicated \u003cstrong\u003eNCV\u003c\/strong\u003e position. The yellow face key is labelled \u003cstrong\u003eSELECT \/ V.F.C.\u003c\/strong\u003e — use V.F.C. only as the manual describes when drive \/ inverter noise may skew a voltage reading. Follow the manual for HOLD, MAX MIN, REL, category limits and lead use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: discrete rotary \u003cstrong\u003e60 A~ \/ 600 A~\u003c\/strong\u003e (pick the range that fits the expected load — no 6 A~ position on this face)\u003c\/li\u003e\n\u003cli\u003eTrue RMS; display \u003cstrong\u003e6000 Counts\u003c\/strong\u003e (face silk)\u003c\/li\u003e\n\u003cli\u003eFace silk: \u003cem\u003e600A AC Digital Clamp Meter\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety markings (face \/ jaw \/ inputs): \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e · CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e0.000\u003c\/strong\u003e with \u003cstrong\u003eAC\u003c\/strong\u003e · \u003cstrong\u003eA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial includes: OFF · 60A~ · 600A~ · voltage \/ Hz positions · Ω \/ diode \/ continuity \/ capacitance · NCV (and related Hz\/% markings as printed)\u003c\/li\u003e\n\u003cli\u003eFace keys: \u003cstrong\u003eSELECT \/ V.F.C.\u003c\/strong\u003e; \u003cstrong\u003eHOLD\u003c\/strong\u003e \/ backlight; \u003cstrong\u003eMAX MIN\u003c\/strong\u003e; \u003cstrong\u003eREL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInputs: COM and V Ω Hz jacks\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to pick the AC range — and when to engage V.F.C.\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eEstimate the expected AC current and open the jaw only when access is safe.\u003c\/li\u003e\n\u003cli\u003eTurn the dial to \u003cstrong\u003e60 A~\u003c\/strong\u003e or \u003cstrong\u003e600 A~\u003c\/strong\u003e so the range covers the load with headroom — do not start on 60 A~ if you expect hundreds of amps inside the listed 600 A AC span.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value, and \u003cstrong\u003eMAX MIN\u003c\/strong\u003e \/ \u003cstrong\u003eREL\u003c\/strong\u003e only as the manual describes for the function you selected.\u003c\/li\u003e\n\u003cli\u003eFor voltage work near a VFD \/ inverter, set the documented voltage dial position first, then use \u003cstrong\u003eSELECT \/ V.F.C.\u003c\/strong\u003e only as the manual describes — V.F.C. is a measurement aid for noisy drive waveforms, not a clamp-current mode and not proof of isolation. For NCV, use the dedicated dial position; NCV is an indication aid only.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut216b-engage-vfc-when-drive-noise-skews-voltage\"\u003eUNI-T UT216B: Engage V.F.C. When Drive Noise Skews Voltage\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT216B\u003c\/li\u003e\n\u003cli\u003eType: True RMS digital clamp meter (600 A AC)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 6000 (face marking)\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T UT216B · True RMS 6000 Counts · 600A AC Digital Clamp Meter\u003c\/li\u003e\n\u003cli\u003eAC current ranges: 60 A~ \/ 600 A~\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 0.000 \/ AC \/ A\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: voltage and frequency paths as printed, resistance \/ diode \/ continuity \/ capacitance, NCV\u003c\/li\u003e\n\u003cli\u003eControls: SELECT \/ V.F.C., HOLD \/ backlight, MAX MIN, REL\u003c\/li\u003e\n\u003cli\u003eSafety markings (face \/ jaw \/ inputs): CAT III 600 V · CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, batteries, soft pouch and the English manual on this buying page before ordering. Follow the supplied manual for accuracy conditions, V.F.C. behaviour, NCV behaviour and measurement-category suitability. Do not treat this page as UT216A, UT216C, UT213B, UT200B+ or UT200A+. Jaw opening size and numeric accuracy tolerances are not claimed here — use the manual. Seller jaw millimetre claims and seller CAT IV lines that conflict with the face silk are ignored; CAT claims on this page follow the face \/ jaw \/ input markings.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT216B\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e600 A AC True RMS, 6000 counts, 60 \/ 600 A~ ranges, SELECT\/V.F.C., NCV limits and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut216b\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut216b-engage-vfc-when-drive-noise-skews-voltage\"\u003eUNI-T UT216B: Engage V.F.C. When Drive Noise Skews Voltage\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849458643003,"sku":"EKO-UT216B","price":186.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT216B_clean_en_1.jpg?v=1793687632"},{"product_id":"uni-t-ut205-clamp-meter","title":"UNI-T UT205 Clamp Meter","description":"\u003cp\u003eThe UNI-T UT205 is a digital clamp meter with a listed maximum of 1000 A AC and a 3999-count display. Its lead functions include voltage, resistance, capacitance, frequency, diode and continuity tests. It measures AC clamp current only; True RMS is not claimed for this model.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e UT205A, UT205A+, UT205B, UT205E, UT216A\/B\/C or UT200A+\/UT200B+. This page is the \u003cstrong\u003eUT205\u003c\/strong\u003e only — a \u003cstrong\u003e1000 A AC\u003c\/strong\u003e clamp with a \u003cstrong\u003e3999-count\u003c\/strong\u003e display (not a True RMS face silk, not a CAT III 600 V sibling, and not a factory A\/A+\/B\/E combo poster). Do not use UT205A \/ A+ \/ B \/ E co-branded images or another UT205-series photo for ranges or accessories.\u003c\/p\u003e\n\n\u003ch2\u003e1000 A AC clamp with 3999 counts, English UI and CAT III 300 V markings\u003c\/h2\u003e\n\u003cp\u003eThe UT205 suits single-conductor AC current checks on the \u003cstrong\u003e1000 A~\u003c\/strong\u003e dial position when the expected load sits inside the listed span. The English display example shows \u003cstrong\u003e399.9\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e, \u003cstrong\u003eAUTO\u003c\/strong\u003e and \u003cstrong\u003emV\u003c\/strong\u003e. Lead and dial functions extend to voltage, the ohms family, capacitance and frequency. Follow the manual for SELECT, Hz, REL Δ, HOLD, category limits and lead use. This face does \u003cstrong\u003enot\u003c\/strong\u003e carry a True RMS silk — do not invent one.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: rotary \u003cstrong\u003e1000 A~\u003c\/strong\u003e (jaw silk \u003cstrong\u003e1000 A~\u003c\/strong\u003e; listing attributes also note \u003cstrong\u003e400 A \/ 1000 A\u003c\/strong\u003e current ranges)\u003c\/li\u003e\n\u003cli\u003eDisplay class: \u003cstrong\u003e3999\u003c\/strong\u003e counts (English UI example peaking at \u003cstrong\u003e399.9\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003eFace silk: \u003cem\u003eUNI-T\u003c\/em\u003e · \u003cem\u003eUT205 CLAMP METER\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face): \u003cstrong\u003eCAT III 300 V\u003c\/strong\u003e · \u003cstrong\u003eCAT II 600 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e399.9\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e · \u003cstrong\u003eAUTO\u003c\/strong\u003e · \u003cstrong\u003emV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial includes: OFF · voltage path · Ω · diode \/ continuity \/ capacitance · Hz · \u003cstrong\u003e1000 A~\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFace keys: backlight · \u003cstrong\u003eHz\u003c\/strong\u003e · \u003cstrong\u003eREL Δ\u003c\/strong\u003e · \u003cstrong\u003eSELECT\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSide control: \u003cstrong\u003eHOLD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInputs: \u003cstrong\u003eHz Ω\u003c\/strong\u003e, \u003cstrong\u003eCOM\u003c\/strong\u003e and \u003cstrong\u003eV\u003c\/strong\u003e jacks\u003c\/li\u003e\n\u003cli\u003ePower (rear door silk): \u003cstrong\u003e9 V\u003c\/strong\u003e (NEDA 1604 \/ 6F22 \/ 006P)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp\u003c\/li\u003e\n\u003cli\u003eNo True RMS face silk on this exact UT205 — do not copy True RMS wording from UT216* \/ UT213B \/ UT200* pages\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to respect CAT III 300 V before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the installation category and expected fault level sit inside the jaw \/ face markings \u003cstrong\u003eCAT III 300 V\u003c\/strong\u003e and \u003cstrong\u003eCAT II 600 V\u003c\/strong\u003e — do not treat a 1000 A current span as a higher category rating.\u003c\/li\u003e\n\u003cli\u003eEstimate the expected AC current against the listed \u003cstrong\u003e1000 A AC\u003c\/strong\u003e span, then turn the dial to \u003cstrong\u003e1000 A~\u003c\/strong\u003e only when access is safe.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use side \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value, and \u003cstrong\u003eREL Δ\u003c\/strong\u003e \/ \u003cstrong\u003eHz\u003c\/strong\u003e \/ \u003cstrong\u003eSELECT\u003c\/strong\u003e only as the manual describes for the function you selected.\u003c\/li\u003e\n\u003cli\u003eFor voltage, ohms family, capacitance or frequency, use the documented dial position \/ leads in the Hz Ω · COM · V jacks and follow SELECT sequences in the manual.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut205-respect-cat-iii-300v-before-you-clamp\"\u003eUNI-T UT205: Respect CAT III 300 V Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT205\u003c\/li\u003e\n\u003cli\u003eType: digital clamp meter (1000 A AC)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 3999\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · UT205 CLAMP METER\u003c\/li\u003e\n\u003cli\u003eAC current: listed 1000 A AC on 1000 A~ (listing attributes also note 400 A \/ 1000 A current ranges)\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 399.9 \/ DC \/ AUTO \/ mV\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: voltage path, resistance \/ diode \/ continuity \/ capacitance, frequency (Hz)\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, Hz, REL Δ, backlight; side HOLD\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face): CAT III 300 V · CAT II 600 V\u003c\/li\u003e\n\u003cli\u003eInputs: Hz Ω · COM · V\u003c\/li\u003e\n\u003cli\u003ePower: 9 V (NEDA 1604 \/ 6F22 \/ 006P — rear door silk)\u003c\/li\u003e\n\u003cli\u003eBody size (listing attribute): 208 × 76 × 30 mm\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): 260 g\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003cli\u003eTrue RMS: not marked on this face — do not invent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, hard case \/ alligator leads (when shown on this buying page), the 9 V cell and the English manual before ordering. Follow the supplied manual for accuracy conditions and measurement-category suitability. Do not treat this page as UT205A, UT205A+, UT205B, UT205E, UT216A\/B\/C or UT200A+\/UT200B+. Jaw opening size and numeric accuracy tolerances are not claimed here — use the manual. Kit photos that show a shared UT205\/206 manual cover still sell the \u003cstrong\u003eUT205\u003c\/strong\u003e meter on this page only.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT205\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e1000 A AC, 3999 counts, CAT III 300 V \/ CAT II 600 V limits, English UI and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut205\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut205-respect-cat-iii-300v-before-you-clamp\"\u003eUNI-T UT205: Respect CAT III 300 V Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849547411515,"sku":"EKO-UT205","price":84.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT205_clean_en_1.jpg?v=1793688094"},{"product_id":"uni-t-ut205a-clamp-meter","title":"UNI-T UT205A Clamp Meter","description":"\u003cp\u003eThe UNI-T UT205A is an auto-range digital clamp meter with a listed 1000 A AC current maximum and a 3999-count display. Lead functions include AC\/DC voltage, resistance, diode, continuity, frequency and duty cycle. Its clamp-current capability is AC only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e the bare UT205 ( sibling), not UT205A+, not UT205B and not UT205E. This page is the \u003cstrong\u003eUT205A\u003c\/strong\u003e only — a \u003cstrong\u003e1000 A AC\u003c\/strong\u003e \u003cstrong\u003efull-auto-range\u003c\/strong\u003e clamp with English UI \u003cstrong\u003e0.000 \/ Hz\u003c\/strong\u003e and face \u003cstrong\u003eHOLD\u003c\/strong\u003e (not the UT205 side-HOLD \/ 399.9 \/ DC \/ AUTO \/ mV layout). Do not use bare-UT205 \/ A+ \/ B \/ E co-branded images or another UT205-series photo for ranges or accessories.\u003c\/p\u003e\n\n\u003ch2\u003e1000 A AC full-auto clamp with 3999 counts and English UI 0.000 \/ Hz\u003c\/h2\u003e\n\u003cp\u003eThe UT205A suits single-conductor AC current checks on the \u003cstrong\u003e1000 A~\u003c\/strong\u003e dial position when the expected load sits inside the listed span. The English display example shows \u003cstrong\u003e0.000\u003c\/strong\u003e with \u003cstrong\u003eHz\u003c\/strong\u003e — that is a frequency-path readout style on this face, not a clamp-amps reading by itself. Lead and dial functions extend to AC \/ DC voltage, the ohms family and frequency \/ duty. Follow the manual for SELECT, HOLD, Hz %, category limits and lead use. No True RMS silk is claimed on this page — do not invent one from sibling models.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current: rotary \u003cstrong\u003e1000 A~\u003c\/strong\u003e (jaw silk \u003cstrong\u003e1000 A~\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003eRanging class (listing \/ title): \u003cstrong\u003efull auto range\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisplay class: \u003cstrong\u003e3999\u003c\/strong\u003e counts\u003c\/li\u003e\n\u003cli\u003eFace silk: \u003cem\u003eUNI-T\u003c\/em\u003e · \u003cem\u003eUT205A\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e0.000\u003c\/strong\u003e with \u003cstrong\u003eHz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial includes: OFF · V⎓ · V~ · Ω \/ diode \/ continuity · Hz % · \u003cstrong\u003e1000 A~\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFace keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e · \u003cstrong\u003eHOLD\u003c\/strong\u003e · \u003cstrong\u003eHz %\u003c\/strong\u003e · backlight\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face on this exact capture): \u003cstrong\u003eCAT III 300 V\u003c\/strong\u003e · \u003cstrong\u003eCAT II 600 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInputs: COM and measurement jacks as marked on the face\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): \u003cstrong\u003e350 g\u003c\/strong\u003e (0.35 kg)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp\u003c\/li\u003e\n\u003cli\u003eNo True RMS \/ NCV claim on this page — do not copy those from UT216* \/ UT213B \/ UT200* pages\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to confirm 1000 A AC before you clamp\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the expected AC current against the listed \u003cstrong\u003e1000 A AC\u003c\/strong\u003e span, then turn the dial to \u003cstrong\u003e1000 A~\u003c\/strong\u003e only when access is safe — full-auto ranging does not mean “any dial position is a clamp amp reading”.\u003c\/li\u003e\n\u003cli\u003eTreat a screen example showing \u003cstrong\u003e0.000 \/ Hz\u003c\/strong\u003e as a frequency-path UI style on this face, not as proof that the jaw is already reading amps.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use face \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value, and \u003cstrong\u003eSELECT\u003c\/strong\u003e \/ \u003cstrong\u003eHz %\u003c\/strong\u003e only as the manual describes for the function you selected.\u003c\/li\u003e\n\u003cli\u003eMatch the installation to the jaw \/ face markings \u003cstrong\u003eCAT III 300 V\u003c\/strong\u003e \/ \u003cstrong\u003eCAT II 600 V\u003c\/strong\u003e on this exact meter — a 1000 A current span does not upgrade the category.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut205a-confirm-1000a-ac-before-you-clamp\"\u003eUNI-T UT205A: Confirm 1000 A AC Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT205A\u003c\/li\u003e\n\u003cli\u003eType: full-auto-range digital clamp meter (1000 A AC)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 3999\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · UT205A\u003c\/li\u003e\n\u003cli\u003eAC current: listed 1000 A AC on 1000 A~\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 0.000 \/ Hz\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: AC \/ DC voltage, resistance \/ diode \/ continuity, frequency \/ duty (Hz %)\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, HOLD, Hz %, backlight\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face on this exact capture): CAT III 300 V · CAT II 600 V\u003c\/li\u003e\n\u003cli\u003eInputs: COM and measurement jacks as marked on the face\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): 350 g\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003cli\u003eTrue RMS \/ NCV: not claimed on this page — do not invent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, the cell type stated in the supplied manual, any hard case \/ kit shown on this buying page and the English manual before ordering. Follow the supplied manual for accuracy conditions and measurement-category suitability. Do not treat this page as UT205, UT205A+, UT205B, UT205E, UT216A\/B\/C or UT200A+\/UT200B+. Jaw opening size, numeric accuracy tolerances and battery chemistry are not invented here — use the manual and the markings on your unit.\u003c\/p\u003e\n\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\n\u003cdiv class=\"eko-learnmore-entry\" style=\"margin:22px 0;padding:20px 22px;background:#f1f4fa;border:1px solid #dce1e8;border-radius:12px\"\u003e\n\u003cp style=\"margin:0 0 7px\"\u003e\u003cstrong\u003eGet to know the UNI-T UT205A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e1000 A AC, full-auto range, 3999 counts, English UI 0.000 \/ Hz and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut205a\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut205a-confirm-1000a-ac-before-you-clamp\"\u003eUNI-T UT205A: Confirm 1000 A AC Before You Clamp\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\n\n\n\n\n\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849597907003,"sku":"EKO-UT205A","price":80.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT205A_clean_en_1.jpg?v=1793688266"},{"product_id":"uni-t-ut206a-plus-clamp-meter","title":"UNI-T UT206A+ Clamp Meter","description":"\u003cdiv class=\"eko-pdp\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT206A+\u003c\/strong\u003e is a digital clamp meter for \u003cstrong\u003e1000 A AC\u003c\/strong\u003e with a \u003cstrong\u003e6000-count\u003c\/strong\u003e display. Face silk: \u003cem\u003eUNI-T\u003c\/em\u003e, \u003cem\u003eUT206A+\u003c\/em\u003e, \u003cem\u003e1000A AC Clamp Meter\u003c\/em\u003e, \u003cem\u003e6000 Counts\u003c\/em\u003e. The rotary clamp-current position is labelled \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e, with dial \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e for non-contact voltage prompting. Jaw \/ face safety markings include \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e and \u003cstrong\u003eCAT II 1000 V\u003c\/strong\u003e, with jaw current silk \u003cstrong\u003e1000 A\u003c\/strong\u003e. English UI example on the display: \u003cstrong\u003e6.099 \/ DC \/ V \/ AUTO\u003c\/strong\u003e. Lead \/ dial paths cover AC voltage \/ frequency, the ohms family, capacitance, frequency \/ duty and temperature (°C \/ °F). Face keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e, \u003cstrong\u003eREL\u003c\/strong\u003e (with backlight) and \u003cstrong\u003eMax \/ Min\u003c\/strong\u003e, plus a side \u003cstrong\u003eHOLD\u003c\/strong\u003e. UK price \u003cstrong\u003e\u003c\/strong\u003e, free delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot\u003c\/strong\u003e bare UT206 \/ UT206A (same-batch HOLD — do not list), not UT206C (pending), not UT205A+ (, 4000 counts, no Inrush \/ NCV silk on that face), not UT205 \/ UT205A \/ UT205E. This page is the \u003cstrong\u003eUT206A+\u003c\/strong\u003e only — a \u003cstrong\u003e1000 A AC\u003c\/strong\u003e clamp with \u003cstrong\u003e6000 counts\u003c\/strong\u003e, dial \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e and \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e, English UI \u003cstrong\u003e6.099 \/ DC \/ V \/ AUTO\u003c\/strong\u003e, face \u003cstrong\u003eSELECT \/ REL \/ Max Min\u003c\/strong\u003e, and jaw \/ face markings \u003cstrong\u003eCAT III 600 V \/ CAT II 1000 V\u003c\/strong\u003e. Do not use 205A+ \/ 206 \/ A \/ C co-branded images or another UT206-series photo for ranges or accessories.\u003c\/p\u003e\n\u003ch2\u003e1000 A AC clamp with 6000 counts, Inrush 1000A~, NCV and English UI 6.099 \/ DC \/ V \/ AUTO\u003c\/h2\u003e\n\u003cp\u003eThe UT206A+ suits single-conductor AC current and inrush checks on the \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e dial position when the expected load sits inside the listed span. The English display example shows \u003cstrong\u003e6.099\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e, \u003cstrong\u003eV\u003c\/strong\u003e and \u003cstrong\u003eAUTO\u003c\/strong\u003e — that is a DC \/ voltage \/ auto-range UI style on this face, not a clamp-amps or inrush reading by itself. Dial \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e prompts for AC electric field presence; it does not prove isolation. Lead and dial functions extend to AC voltage \/ frequency, the ohms family, capacitance, frequency \/ duty and temperature. Follow the manual for SELECT, REL, Max \/ Min, side HOLD, Inrush behaviour, NCV behaviour, category limits and lead use. No True RMS silk is claimed on this page — do not invent one from sibling models.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC current \/ inrush: rotary \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e (jaw silk \u003cstrong\u003e1000 A\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003eDisplay class: \u003cstrong\u003e6000\u003c\/strong\u003e counts (face silk \u003cem\u003e6000 Counts\u003c\/em\u003e; English UI example peaking at \u003cstrong\u003e6.099\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003eFace silk: \u003cem\u003eUNI-T\u003c\/em\u003e · \u003cem\u003eUT206A+\u003c\/em\u003e · \u003cem\u003e1000A AC Clamp Meter\u003c\/em\u003e · \u003cem\u003e6000 Counts\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face on this exact capture): \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e · \u003cstrong\u003eCAT II 1000 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnglish UI example: display \u003cstrong\u003e6.099\u003c\/strong\u003e with \u003cstrong\u003eDC\u003c\/strong\u003e · \u003cstrong\u003eV\u003c\/strong\u003e · \u003cstrong\u003eAUTO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRotary dial includes: OFF · \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e · Hz \/ V~ · Ω \/ diode \/ continuity \/ capacitance · Hz % · °C \/ °F · \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFace keys: \u003cstrong\u003eSELECT\u003c\/strong\u003e · \u003cstrong\u003eREL\u003c\/strong\u003e (backlight) · \u003cstrong\u003eMax \/ Min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSide control: \u003cstrong\u003eHOLD\u003c\/strong\u003e (torch \/ flashlight icon as on this capture)\u003c\/li\u003e\n\u003cli\u003eInputs: COM and VΩHz measurement jack as marked on the face\u003c\/li\u003e\n\u003cli\u003eBattery (rear door silk on this capture): \u003cstrong\u003e2 × 1.5 V AAA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): \u003cstrong\u003e240 g\u003c\/strong\u003e (0.24 kg)\u003c\/li\u003e\n\u003cli\u003eThis model lists \u003cstrong\u003eAC current\u003c\/strong\u003e on the clamp — it is \u003cstrong\u003enot\u003c\/strong\u003e a DC-current clamp\u003c\/li\u003e\n\u003cli\u003eNo True RMS claim on this page — do not copy True RMS wording from UT216* \/ UT213B \/ UT200* pages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to set Inrush before you read the peak\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the expected AC current \/ starting surge against the listed \u003cstrong\u003e1000 A AC\u003c\/strong\u003e span, then turn the dial to \u003cstrong\u003eInrush 1000A~\u003c\/strong\u003e only when access is safe — Max \/ Min or a frozen peak does not mean “any dial position is already an inrush reading”.\u003c\/li\u003e\n\u003cli\u003eTreat a screen example showing \u003cstrong\u003e6.099 \/ DC \/ V \/ AUTO\u003c\/strong\u003e as a DC \/ voltage \/ auto-range UI style on this face, not as proof that the jaw is already reading amps or capturing inrush.\u003c\/li\u003e\n\u003cli\u003eClamp a \u003cstrong\u003esingle\u003c\/strong\u003e suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading; use face \u003cstrong\u003eMax \/ Min\u003c\/strong\u003e or \u003cstrong\u003eREL\u003c\/strong\u003e only as the manual describes for the function you selected, and side \u003cstrong\u003eHOLD\u003c\/strong\u003e if you need to step away from the conductor to note the value. Follow the manual for how \u003cstrong\u003eInrush\u003c\/strong\u003e captures the starting surge on this model.\u003c\/li\u003e\n\u003cli\u003eMatch the installation to the jaw \/ face markings \u003cstrong\u003eCAT III 600 V\u003c\/strong\u003e \/ \u003cstrong\u003eCAT II 1000 V\u003c\/strong\u003e on this exact meter — a 1000 A current span does not replace category matching. Treat dial \u003cstrong\u003eNCV Lo Hi\u003c\/strong\u003e as a prompt only, never as isolation proof.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSee also: \u003ca href=\"\/blogs\/guides\/uni-t-ut206a-plus-set-inrush-before-you-read-the-peak\"\u003eUNI-T UT206A+: Set Inrush Before You Read the Peak\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UNI-T UT206A+\u003c\/li\u003e\n\u003cli\u003eType: digital clamp meter (1000 A AC · Inrush)\u003c\/li\u003e\n\u003cli\u003eDisplay counts: 6000\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · UT206A+ · 1000A AC Clamp Meter · 6000 Counts\u003c\/li\u003e\n\u003cli\u003eAC current \/ inrush: listed 1000 A AC on Inrush 1000A~\u003c\/li\u003e\n\u003cli\u003eNCV: dial NCV Lo Hi (prompt only — not isolation proof)\u003c\/li\u003e\n\u003cli\u003eDisplay UI (English example): 6.099 \/ DC \/ V \/ AUTO\u003c\/li\u003e\n\u003cli\u003eLead \/ dial functions: AC voltage \/ frequency, resistance \/ diode \/ continuity, capacitance, frequency \/ duty (Hz %), temperature (°C \/ °F)\u003c\/li\u003e\n\u003cli\u003eControls: SELECT, REL (backlight), Max \/ Min; side HOLD\u003c\/li\u003e\n\u003cli\u003eSafety markings (jaw \/ face on this exact capture): CAT III 600 V · CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eInputs: COM and VΩHz measurement jack as marked on the face\u003c\/li\u003e\n\u003cli\u003eBattery (rear door silk on this capture): 2 × 1.5 V AAA\u003c\/li\u003e\n\u003cli\u003eProduct weight (listing attribute): 240 g\u003c\/li\u003e\n\u003cli\u003eCurrent method: AC clamp only (no DC current range on this model)\u003c\/li\u003e\n\u003cli\u003eTrue RMS: not claimed on this page — do not invent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm leads, any hard case \/ kit shown on this buying page and the English manual before ordering. Follow the supplied manual for accuracy conditions, Inrush timing behaviour, NCV behaviour and measurement-category suitability. Do not treat this page as UT206, UT206A, UT206C, UT205A+, UT205, UT205A, UT205E, UT216A\/B\/C or UT200A+\/UT200B+. Jaw opening size and numeric accuracy tolerances are not invented here — use the manual and the markings on your unit.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available.\u003c\/p\u003e\n\u003cp\u003eGet to know the UNI-T UT206A+ — 1000 A AC, 6000 counts, Inrush 1000A~, NCV, English UI 6.099 \/ DC \/ V \/ AUTO, CAT III 600 V markings and model distinctions before you choose. \u003ca href=\"\/pages\/learn-uni-t-ut206a-plus\"\u003eLearn more →\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat AC current does the UT206A+ list?\u003c\/h3\u003e\n\u003cp\u003eListed 1000 A AC on the rotary Inrush 1000A~ position, with jaw silk 1000 A. It is a 1000 A AC clamp with an Inrush path, not a DC-current clamp and not the UT205A+ \/ bare UT206 layout.\u003c\/p\u003e\n\u003ch3\u003eWhat does Inrush 1000A~ do on this meter?\u003c\/h3\u003e\n\u003cp\u003eIt is the rotary clamp-current \/ inrush position silk-printed on this exact face. Set Inrush 1000A~ before treating a peak or Max\/Min value as a starting-surge reading. Follow the supplied manual for capture timing and accuracy conditions — do not invent Inrush behaviour from sibling pages.\u003c\/p\u003e\n\u003ch3\u003eWhat does the English UI 6.099 \/ DC \/ V \/ AUTO mean on this page?\u003c\/h3\u003e\n\u003cp\u003eIt is the English display example on this exact face — a DC \/ voltage \/ auto-range readout style. It is not a screen-size claim and not, by itself, a clamp-amps or inrush reading. Set Inrush 1000A~ before treating the jaw path as AC current.\u003c\/p\u003e\n\u003ch3\u003eDoes NCV prove a circuit is safe \/ isolated?\u003c\/h3\u003e\n\u003cp\u003eNo. Dial NCV Lo Hi is a non-contact voltage prompt only. It does not prove isolation, does not measure amps, and does not authorise live work. Use the correct safe-isolation equipment and procedure for the installation.\u003c\/p\u003e\n\u003ch3\u003eDoes it measure DC current? Is it True RMS?\u003c\/h3\u003e\n\u003cp\u003eNo DC current clamp range is listed on this model — it is a 1000 A AC clamp (Inrush 1000A~). No True RMS claim is made on this page from face silk. Do not copy True RMS wording from UT216*, UT213B or UT200* pages. Follow the manual’s accuracy conditions for the function and range you select.\u003c\/p\u003e\n\u003ch3\u003eHow is UT206A+ different from UT205A+ and from UT206 \/ UT206A \/ UT206C?\u003c\/h3\u003e\n\u003cp\u003eThis page is UT206A+ only. Confirmed differences vs UT205A+  include 6000 counts (vs 4000), dial Inrush 1000A~ and NCV Lo Hi (UT205A+ face uses 1000 A~ without Inrush \/ NCV silk on that capture), English UI 6.099 \/ DC \/ V \/ AUTO (vs 4.099 \/ DC \/ AUTO), and temperature °C \/ °F on this dial. Bare UT206 \/ UT206A are same-batch HOLD (do not list or borrow their photos). UT206C is pending — do not use A\/C combo posters. Price on this page: .\u003c\/p\u003e\n\u003ch3\u003eIs UK delivery free?\u003c\/h3\u003e\n\u003cp\u003eYes. Free UK delivery. Orders usually dispatch within 1–2 working days and arrive about 5–7 working days after dispatch. \u003c\/p\u003e\n\n\u003ch2\u003eLearn more\u003c\/h2\u003e\n\u003cp\u003eRead the \u003ca href=\"\/pages\/learn-uni-t-ut206a-plus\"\u003eUNI-T UT206A+ overview\u003c\/a\u003e and the field guide \u003ca href=\"\/blogs\/guides\/uni-t-ut206a-plus-set-inrush-before-you-read-the-peak\"\u003eSet Inrush Before You Read the Peak\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44849737793595,"sku":"EKO-UT206A+","price":84.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/UT206A_plus_clean_en_1.jpg?v=1793689143"},{"product_id":"uni-t-ut205a-plus-clamp-meter","title":"UNI-T UT205A+ Clamp Meter","description":"\u003cp\u003eThe UNI-T UT205A+ is a 1000 A AC digital clamp meter with a 4000-count-class display. Its lead functions include AC\/DC voltage, resistance, capacitance and frequency, with SELECT, relative and MAX\/MIN controls. This is the plus-suffix UT205A+.\u003c\/p\u003e\n\u003cp\u003eThe UNI-T UT205A+ is a 1000 A AC digital clamp meter (clamp-on ammeter) for single-conductor AC current checks and related lead measurements — not UT205A without the +, not UT206A+, and not bare UT205. Face silk on this capture: UNI-T · UT205A+ · 1000A AC Clamp Meter · 4000 Counts · CAT II 1000V · CAT III 600V. Rotary path on this face includes OFF · V~ · V⎓ · Ω \/ diode \/ continuity \/ capacitance · Hz% · 1000A~. Face \/ side keys on this capture: SELECT · REL \/ backlight · Max\/Min · HOLD (side, with flashlight icon). Manufacturer-style attributes commonly listed for this plus model: AC current to 1000 A, AC\/DC voltage to 1000 V, resistance to 40 MΩ, capacitance to 40 mF, frequency 10 Hz–10 MHz class, jaw opening about 45 mm, display-count class 4099, body about 240 × 76 × 40 mm (supplier key attributes) \/ ~242 × 76.5 × 52 mm (manufacturer sheet class), mass 0.235 kg including batteries. Confirm kit contents on this buying page.  free delivery.\u003c\/p\u003e\n\u003cp\u003eNot UNI-T UT205A without the + (separate in-store listing), not UT206A+ (sibling that adds NCV \/ inrush \/ temperature on the same dual-model supplier posters), and not bare UT205. This page is UT205A+ only — face silk carries the + suffix. Do not share photos, dial claims or kit lists with UT205A \/ UT206A+ \/ UT205. No True RMS wording is claimed from face silk on this capture — do not invent one from other UNI-T clamp pages. No NCV \/ inrush \/ temperature claim on this SKU — those belong to UT206A+.\u003c\/p\u003e\n\u003ch2\u003e1000 A AC clamp with plus silk — confirm UT205A+ before you buy\u003c\/h2\u003e\n\u003cp\u003eThe UT205A+ suits single-conductor AC current checks on the 1000 A~ dial position when the expected load sits inside the listed span, plus lead paths for AC\/DC voltage, the ohms family (resistance \/ diode \/ continuity \/ capacitance) and frequency \/ duty. Confirm face silk UT205A+ (with the +), then use SELECT \/ REL \/ Max\/Min \/ HOLD as the manual describes. That is a different listing identity from the in-store UT205A (no +) and from UT206A+. This page does not invent numeric accuracy ladders beyond published attribute ranges. Confirm kit contents on this buying page before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: 1000 A AC digital clamp meter \/ clamp-on ammeter\u003c\/li\u003e\n\u003cli\u003eFace silk: UNI-T · UT205A+ · 1000A AC Clamp Meter · 4000 Counts\u003c\/li\u003e\n\u003cli\u003eAC current (attribute): to 1000 A on 1000A~\u003c\/li\u003e\n\u003cli\u003eLead \/ dial paths: AC\/DC voltage · Ω \/ diode \/ continuity \/ capacitance · Hz%\u003c\/li\u003e\n\u003cli\u003eDisplay: face silk 4000 Counts; manufacturer display-count class 4099\u003c\/li\u003e\n\u003cli\u003eJaw opening (attribute): about 45 mm\u003c\/li\u003e\n\u003cli\u003eSafety silk (face \/ jaw on this capture): CAT II 1000V · CAT III 600V\u003c\/li\u003e\n\u003cli\u003eKeys (capture): SELECT · REL \/ backlight · Max\/Min · HOLD (side + flashlight)\u003c\/li\u003e\n\u003cli\u003eBody mass (attribute): 0.235 kg\u003c\/li\u003e\n\u003cli\u003eStrong contrast: UT205A+ only — ≠ UT205A · ≠ UT206A+ · ≠ UT205\u003c\/li\u003e\n\u003cli\u003eNot claimed here: True RMS silk · NCV · inrush · temperature (UT206A+ sibling features)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to take a useful reading\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the expected AC current against the listed 1000 A AC span and that access is safe. Observe CAT II 1000V \/ CAT III 600V markings — a 1000 A current span does not upgrade the category.\u003c\/li\u003e\n\u003cli\u003eConfirm face silk UNI-T · UT205A+ with the + suffix. Do not borrow UT205A (no +) \/ UT206A+ \/ UT205 photos or procedures.\u003c\/li\u003e\n\u003cli\u003eTurn the dial to 1000A~ for clamp amps, or to the lead function the manual describes. Clamp a single suitable conductor — not an entire twin-and-earth or both go-and-return paths together.\u003c\/li\u003e\n\u003cli\u003eWait for a stable reading. Use HOLD if you need to step away; use SELECT \/ REL \/ Max\/Min only as the manual describes for the function you selected.\u003c\/li\u003e\n\u003cli\u003eRecord dial position, point identity and the reading with the method reference. This page does not declare a legal pass\/fail.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUNI-T UT205A+ (plus — not UT205A without +)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1000 A AC digital clamp meter \/ clamp-on ammeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFace silk\u003c\/td\u003e\n\u003ctd\u003eUNI-T · UT205A+ · 1000A AC Clamp Meter · 4000 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current\u003c\/td\u003e\n\u003ctd\u003eto 1000 A on 1000A~ (supplier \/ manufacturer attribute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC \/ DC voltage\u003c\/td\u003e\n\u003ctd\u003eto 1000 V (manufacturer attribute class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eto 40 MΩ (manufacturer attribute class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eto 40 mF (manufacturer attribute class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10 Hz ~ 10 MHz class (manufacturer attribute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eface silk 4000 Counts; count class 4099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd\u003eabout 45 mm (manufacturer attribute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety silk\u003c\/td\u003e\n\u003ctd\u003eCAT II 1000V · CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody (supplier key attr.)\u003c\/td\u003e\n\u003ctd\u003eabout 240 × 76 × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.235 kg (product Weight attribute \/ 235 g incl. batteries class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeys (capture)\u003c\/td\u003e\n\u003ctd\u003eSELECT · REL \/ backlight · Max\/Min · HOLD (side + flashlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContrast\u003c\/td\u003e\n\u003ctd\u003e≠ UT205A · ≠ UT206A+ · ≠ UT205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot on this SKU\u003c\/td\u003e\n\u003ctd\u003eNCV · inrush · temperature · True RMS face-silk claim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eConfirm leads, the cell type stated in the supplied manual, any soft case \/ kit shown on this buying page and the English manual before ordering. Follow the supplied manual for accuracy conditions and measurement-category suitability. Exact numeric accuracy ladders and battery chemistry details beyond the attribute notes above are not invented here — use the manual and the markings on your unit.\u003c\/p\u003e\n\u003cp\u003eFree UK delivery. Dispatched in 1–2 working days, delivered in 5–7 working days. Price incl. VAT, VAT invoices available. Europe: free delivery likewise; displayed EUR price follows the store Markets catalog (not a handwritten euro figure on learn\/guides pages).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGet to know the UNI-T UT205A+\u003c\/strong\u003e — overview on \u003ccode\u003e\/pages\/learn-uni-t-ut205a-plus\u003c\/code\u003e. Related guide: \u003ccode\u003e\/blogs\/guides\/uni-t-ut205a-plus-confirm-plus-silk-before-you-clamp\u003c\/code\u003e.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\n\n\n\n\n\n\n\n\u003ch3\u003eWhen will my order arrive?\u003c\/h3\u003e\n\u003cp\u003eDispatched within 1–2 working days. Delivered in 5–7 working days after dispatch.\u003c\/p\u003e\n\u003ch3\u003eWhat is the return policy?\u003c\/h3\u003e\n\u003cp\u003eYou can return a product (including bins) within 30 days. See our returns page for details.\u003c\/p\u003e\n\u003ch3\u003eIs checkout secure?\u003c\/h3\u003e\n\u003cp\u003ePayment is processed through Shopify's secure checkout.\u003c\/p\u003e\n\u003ch3\u003eHow can I contact support?\u003c\/h3\u003e\n\u003cp\u003eEmail support@ekodeluxe.co.uk.\u003c\/p\u003e\n\u003csection class=\"eko-product-scene\" data-scene-id=\"p8088875335739-single-conductor-clamp\" style=\"margin:30px 0;max-width:100%;overflow-wrap:anywhere\"\u003e\u003ch2\u003eIn use: keep one conductor inside the jaw\u003c\/h2\u003e\n\u003cp\u003eClose the exact clamp around one suitable insulated conductor of a low-voltage training circuit, with the return lead outside the jaw and all equipment covered. Show access and jaw position, not a current value or a live-mains claim.\u003c\/p\u003e\n\u003cfigure style=\"margin:18px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/eko-scene-20261117-productssunburst50-p8088875335739-single-conductor-clamp-v1.webp?v=1794924762\" alt=\"UNI-T UT205A+ Clamp Meter clamp meter around one insulated conductor on a training bench\" width=\"1536\" height=\"1024\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:100%;height:auto;border-radius:10px\"\u003e\u003cfigcaption style=\"margin-top:10px;font-size:0.9em;line-height:1.6;color:#4b5563\"\u003eAI-generated scene illustration using product reference images: UNI-T UT205A+ Clamp Meter clamp meter around one insulated conductor on a training bench. This illustrates placement and workflow, not a measured result or an included-accessory list.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":44873655648315,"sku":"EKO-UT205A+","price":90.26,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/6197\/2795\/files\/uni-t-ut205a-plus-clamp-meter-1.jpg?v=1793792749"}],"url":"https:\/\/ekodeluxe.co.uk\/collections\/ac-dc-clamp-meters.oembed","provider":"EkoDeluxe","version":"1.0","type":"link"}